Untitled
Abstract: No abstract text available
Text: PADDLEWHEEL FLOW SENSOR SYSTEMS Model FP7000 $ 200 MADE IN USA ߜ Very Economical ߜ Wide Chemical Compatibility ߜ High Level Pulse Output - No Amplifier Needed PADDLEWHEEL SENSOR LOCKNUT FLOW Shown Smaller Than Actual Size OMEGA FP7000 paddlewheel flow
|
Original
|
FP7000
FP7000
FPW-15
FP7007
FP7010
FP7012
FP7015
FP7020
FP7025
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ECONOMICAL SENSOR-POWERED FLOW INDICATORS FPM-5800 Series $ 322 MADE IN USA FM APPROVED ߜ Sensor Powered ߜ Economical Flow Monitoring ߜ Front Panel Calibration ߜ Splash-Proof, ShatterResistant Acrylic Front Panel Easy to Install Self-Powered Flow System
|
Original
|
FPM-5800
FP-5300
FP-5100
FPM-5800.
FPM-5800-SCALED-
FPM-5800-SCALED-
FP-5307
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FIBER-OPTIC INPUT FLOW SIGNAL CONDITIONER FOR USE WITH THE LIGHTSPEED PADDLEWHEEL FLOW SENSOR Model FP9001 Fiber Optic Flow Sensor Paddlewheel is Covered by U.S. and Foreign Patents and Pending Applications ߜ 0.15% Accuracy ߜ 4-20 mA or 1-5 Vdc Output
|
Original
|
FP9001
FLSC90-A
FLSC90-A
FP-9000
FP9000A
FLSC90-A,
TX4-100,
|
PDF
|
Heating, Ventilation and Air Conditioning
Abstract: No abstract text available
Text: AWM3100V Actual product appearance may vary. Potential Applications Features • • • Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: + 200 sccm; Port Style: Straight Laser trimmed for improved sensor interchangeability Flow sensing up to 1.0
|
Original
|
AWM3100V
AWM2000
AWM3000
AWM3000
Heating, Ventilation and Air Conditioning
|
PDF
|
airflow sensors 0-10 slpm
Abstract: AWM3000 Series Heating, Ventilation and Air Conditioning
Text: AWM3150V Actual product appearance may vary. Potential Applications Features • • • Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: + 30.0 sccm; Port Style: Straight Laser trimmed for improved sensor interchangeability Flow sensing up to 1.0
|
Original
|
AWM3150V
AWM2000
AWM3000
AWM3000
airflow sensors 0-10 slpm
AWM3000 Series
Heating, Ventilation and Air Conditioning
|
PDF
|
sensor Flow meter PNP
Abstract: sensor DN15 npn transistor dc 558 en 175301-803 burkert s070 DD0-2 transistor 1451 "Flow Sensor" DN25 DN50
Text: 8070 Positive displacement Flow sensor for continuous flow measurement • High accuracy • Medium with high viscosity • Mounting and dismounting of the sensor head by a quarter-turn • Connection to Bürkert devices in remote versions Type 8070 can be combined with.
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Thermal Dispersion & Paddle Type Flow Switch visit our website PRODUCT INTRODUCTION OPERATING PRINCIPLE Thermal dispersion flow switches measure the velocity of a liquid inside a pipe or channel. The switch’s probe contains two key components – a heating sensor and temperature sensor. The
|
Original
|
D-65428
08-SPSF-B0-EP,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RUGGED, RELIABLE ALL-METAL SENSORS MADE IN USA 1 ⁄2" FNPT Conduit Port 316 Stainless Steel Sensor CD4MCU Stainless Steel Rotor Use the metal flow sensor for monitoring or controlling flow in: • Secondary Oil Recovery • Boiler Water Feed Lines Model FP-5200
|
Original
|
FP-5200
FP-5200
FP-5201
FP-5202
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MICRO-FLOW SENSORS For Low Flow Applications FP-5060 Series $ 281 ߜ Measures Flow Rates As Low As 0.03 gpm, 0.11 l/m ߜ Splash-Proof ߜ All Plastic Construction for Superior Chemical and Corrosion Resistance The FP-5060 series micro-flow sensor is constructed from
|
Original
|
FP-5060
FP-5060
FP-5061
FP-5062
FP-5063
FP-5064
FP-5063,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ECONOMICAL SENSORPOWERED FLOW INDICATORS MADE IN USA FM APPROVED FPM-5800 Series 322 $ ߜ Sensor Powered ߜ Economical Flow Monitoring ߜ Front Panel Calibration ߜ Splash-Proof, Shatter-Resistant Acrylic Front Panel Easy to Install Self-Powered Flow System
|
Original
|
FPM-5800
FP-5300
FP-5100
FPM-5800.
FPM-5800
FPM-5800-SCALED-
FP-5307
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Multi-Function Meter For Batch Control, Rate Indication and Totalization DPF5100 Series 380 $ Basic Unit MADE IN USA Shown smaller than actual size with FP7000 Series paddlewheel flow sensor $200, sold separately , see section F in OMEGA’s Flow Handbook.
|
Original
|
DPF5100
FP7000
RS-232C
|
PDF
|
wheatstone bridge in pressure sensor
Abstract: mass air flow sensor wheatstone bridge pressure sensor awm mass airflow sensor pressure sensor response time ms oxygen gas sensor "Air Flow Sensor", medical Wheatstone Bridge medical
Text: AWM2100V Airflow Sensor, Signal Conditioning: Unamplified mV ; Flow/Pressure Actual product appearance may Range: ± 200 sccm; Port vary. Style: Straight Potential Applications Features • • • Bidirectional sensing capability Actual mass air flow sensing
|
Original
|
AWM2100V
AWM2000
AWM2000
wheatstone bridge in pressure sensor
mass air flow sensor
wheatstone bridge pressure sensor
awm mass airflow sensor
pressure sensor response time ms
oxygen gas sensor
"Air Flow Sensor", medical
Wheatstone Bridge medical
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Thermo-Flo FT10/GT10 Liquid & Gas Flow Switch Application _T10-1405 _T10-1305 Offered in liquid and gas sensor types, the general purpose flow switch provides reliable low or no-flow detection of relatively clean, non-coating media with one 1A relay output. Liquid examples include water
|
Original
|
FT10/GT10
T10-1405
T10-1305
D25-D50)
DS900003
|
PDF
|
173940-C
Abstract: 173937-C 173936-C 173939-C Gems Sensors FT-110 series 173934 173936 FT-110 173931 173933-C
Text: Turbine Flow Rate Sensor FT-110 Series Instruction Bulletin No. 173926 Operating and Installation Instructions Prior to installation, confirm system versus sensor specifications and media compatibility of sensor. The system needs to be filtered to 50 microns prior to the sensor, and pulses/water hammer effects should be
|
Original
|
FT-110
173940-C
173937-C
173936-C
173939-C
Gems Sensors FT-110 series
173934
173936
173931
173933-C
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: NFC130 Flow Computer For Low Pulses and AC Power FEATURES l STABLE READING WITH PULSES DOWN TO ONE PULSE EVERY 5 MINUTES l ALARM RELAY WITH PROGRAMMABLE DELAY TO 600 sec AND REMOTE RESET l MULTIPLE INPUTS UP TO 120 Hz, CAN POWER THE SENSOR l WORKS WITH OPTO-COUPLER FLOW METERS
|
Original
|
NFC130
|
PDF
|
Untitled
Abstract: No abstract text available
Text: THE FL0W SENSOR THAT MAKES SHORT WORK OF YOUR FLOW MEASUREMENTS FP-5100/5300 Paddlewheel Flow Sensors $ 253 Basic Unit Patented “flow- through” rotor design ensures accurate, linear output to ±1% Shown Actual Size A TIMESAVER YOU CAN BANK ON Convert your maintenance hours
|
Original
|
FP-5100/5300
FP-5300.
FP-5300
FP-5300,
FP-5310,
FP-3193
FP-3194
FP-3195
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PADDLEWHEEL FLOW SENSOR/ TRANSMITTER SYSTEM Model FP7002 $ 365 ߜ Wide Chemical Compatibility ߜ 4-20 mA or 1-5 Vdc Field Selectable Output ߜ NEMA-4 Housing ߜ Compact Industrial Design Includes Both Paddlewheel Sensor and Process Transmitter in One Assembly
|
Original
|
FP7002
FP7000
FP70y
FP7007
FP7010
FP7012
FP7015
FP7020
FP7025
FP7030
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Velociti Series ADPF and ADPRF Analog Addressable Low-Flow Duct Sensor Description The Gamewell-FCI Velociti® Series, low-flow photoelectronic air duct smoke sensors are capable of sensing smoke in air velocities from 100 to 4,000 feet per minute 0.5 to 20.32 m/sec. .
|
Original
|
RTS451
RTS451KEY
RA400Z
F36-09-11
M02-04-00
P48-21-00
P48-61-00
S08-39-01
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MODEL FP6000 ADJUSTABLE DEPTH BRASS FLOW SENSORS Doesn’t Need Special Installation Fittings! FP-6000 63.5 2.5 $ 426 MADE IN USA 7.5 m (25') Integral cable ߜ One Sensor for Lines 11⁄2" to 36" ߜ No Special Fitting Needed ߜ Low Cost When you want it all in one flow
|
Original
|
FP6000
FP-6000
FP-6000
DPF700,
DPF70
FP85A,
FPM-5500,
|
PDF
|
moisture sensor
Abstract: resistor Uninterruptible power supply application Water Meter wind velocity sensor Air Sensor
Text: R Clogged Air Filter Sensor D6A Detect Clogged Fan Filters to Prevent Overheating of Equipment H Sensor detects air flow over a 0.5 to 1.5 m/sec range; provides analog voltage output of 0 to 5 VDC H Algorithms provide a temperature reference point to determine if a filter
|
Original
|
E10DAD1
moisture sensor
resistor
Uninterruptible power supply application
Water Meter
wind velocity sensor
Air Sensor
|
PDF
|
Wheatstone bridge catalog
Abstract: AWM40000 AWM42300V mass air flow sensor gas sensor
Text: Interactive Catalog - Honeywell Sensing and Control AWM42300V Representative photograph, actual product appearance may vary. Airflow Sensor, Signal Conditioning: Unamplified mV ; Flow/Pressure Range: ± 1000 sccm (1.0 SLPM); Port Style: Manifold Features
|
Original
|
AWM42300V
Wheatstone bridge catalog
AWM40000
AWM42300V
mass air flow sensor
gas sensor
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FLOW & LEVEL INSTRUMENTATION Digital Open Channel Water Velocity Meters MADE IN USA FPG-100 Series $ 695 Basic Model FPG-101 $695 ߜ Ideal for Storm Water, Rivers, Ditches, Flumes, Sewers, Effluents, Canals, Creeks ߜ Turbo-Propeller Sensor ߜ Waterproof Digital Display
|
Original
|
FPG-100
FPG-101
FPG-101
FPG-201
FPG-201
FPG-201,
|
PDF
|
AWM43300V
Abstract: AWM40000
Text: Datasheet - AWM43300V AWM43300V Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: + 1000 sccm 1.0 SLPM ; Port Style: Manifold Representative photograph, actual product appearance may vary. Features ● ● ● ● Due to regional agency approval
|
Original
|
AWM43300V
AWM43300V
AWM40000
|
PDF
|
ecg semiconductors master replacement guide
Abstract: ECG transistor replacement guide book free ad620 strain gauge pressure sensor schematic weigh scale AD7730 SD-020-12-001 Linear inductosyn ad7730 pcb circuit example pcb ad7730 op amp 741 model PSpice Schaevitz e100
Text: PRACTICAL DESIGN TECHNIQUES FOR SENSOR SIGNAL CONDITIONING INTRODUCTION - 1 BRIDGE CIRCUITS - 2 AMPLIFIERS FOR SIGNAL CONDITIONING - 3 STRAIN, FORCE, PRESSURE, AND FLOW MEASUREMENTS - 4 HIGH IMPEDANCE SENSORS - 5 POSITION AND MOTION SENSORS - 6 TEMPERATURE SENSORS -
|
Original
|
ADSP-2100
ADSP-2101
OP113,
OP177,
OP177A,
OP181,
OP184,
OP191,
OP193,
ecg semiconductors master replacement guide
ECG transistor replacement guide book free
ad620 strain gauge pressure sensor
schematic weigh scale AD7730
SD-020-12-001
Linear inductosyn
ad7730 pcb circuit example
pcb ad7730
op amp 741 model PSpice
Schaevitz e100
|
PDF
|