Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SHORT CIRCUIT CONTACTOR Search Results

    SHORT CIRCUIT CONTACTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TLP2701 Toshiba Electronic Devices & Storage Corporation Photocoupler (photo-IC output), 5000 Vrms, 4pin SO6L Visit Toshiba Electronic Devices & Storage Corporation
    74HC4053FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SPDT(1:2)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    74HC4051FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SP8T(1:8)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NA Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Auto-retry, WSON10B Visit Toshiba Electronic Devices & Storage Corporation
    TCKE800NL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 18 V, 5.0 A, Latch, WSON10B Visit Toshiba Electronic Devices & Storage Corporation

    SHORT CIRCUIT CONTACTOR Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    193-EEFD

    Abstract: 140M-K8P-D40 rockwell E3 plus relay 140M-J8P-D25 193-EEGE 193-EEJF 193-EEHF 140M D18011 140M-J8P-D20
    Text: TECHNICAL DATA BULLETIN 100/140M/193 MCS Short-Circuit Current Ratings Short-Circuit Protection Ratings Starting: Short-circuit protective device: Direct-on-line and reversing Bulletin 140M Motor Circuit Protector MCP UL 489 magnetic only Contactor: Bulletins 100-C, 100-D


    Original
    100/140M/193 100-C, 100-D 193-E1 100-D210 100-TD100B-EN-P 100-TD100A-EN-P 193-EEFD 140M-K8P-D40 rockwell E3 plus relay 140M-J8P-D25 193-EEGE 193-EEJF 193-EEHF 140M D18011 140M-J8P-D20 PDF

    DTH circuit diagram

    Abstract: DTH block diagram
    Text: MOULDED CASE CIRCUIT BREAKERS 2 DS Page DTH.E Page DG Page Adjustable Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit release with Normal Breaking Capacity release with High Breaking Capacity Technical Data


    Original
    2/58ROTECTION DTH circuit diagram DTH block diagram PDF

    ul508a

    Abstract: SCCR-TD001A-EN-P SCCR-SP001A-EN-P 140M-C2E-A16 1492-TD013A-EN-P CCLP-TD001A-EN-P UL508A-2001 65kA 65kA terminal blocks nec marking BOOK
    Text: Short Circuit Current Ratings TECHNICAL DATA UNDERSTANDING NEC ARTICLE 409 AND UL 508A, SUPPLEMENT SB SHORT CIRCUIT CURRENT RATINGS Short Circuit Current Rating Technical Data National Electric Code Changes Overview National Electrical Code Introduces Article 409 for Industrial Control Panels


    Original
    SCCR-SP001A-EN-P 1492-TD013A-EN-P CCLP-TD001A-EN-P SCCR-TD001A-EN-P ul508a SCCR-SP001A-EN-P 140M-C2E-A16 1492-TD013A-EN-P CCLP-TD001A-EN-P UL508A-2001 65kA 65kA terminal blocks nec marking BOOK PDF

    ABB A26-30-10

    Abstract: star delta timer starter diagram magnetic Contactor abb a9-30-10 star delta starter diagram star delta wiring diagram with magnetic and timer wiring diagram star delta starter wiring diagram ABB motor starter VE 5-2 ABB 3 phase 380v motor starter overload relay chart A9-30-10
    Text: Application Guide Motor Starting Solutions Open Type Version In Kit Form Complete Range of Products and Accessories to Create all Motor Starter Types Manual motor starter Short-Circuit Protection. Type 1 or 2 coordination guaranteed between contactors and short-circuit


    Original
    R2000 1SBC101001C0201 F-69685 C0201 ABB A26-30-10 star delta timer starter diagram magnetic Contactor abb a9-30-10 star delta starter diagram star delta wiring diagram with magnetic and timer wiring diagram star delta starter wiring diagram ABB motor starter VE 5-2 ABB 3 phase 380v motor starter overload relay chart A9-30-10 PDF

    Short Circuit Current Ratings & Solid State Relays

    Abstract: NEC RELAY DE
    Text: 1 Short Circuit Current Ratings & Solid State Relays Paul Bachman Fellow Engineer Crydom CHALLENGES FOR INDUSTRIAL PANEL BUILDERS The 2005 National Electrical Code more information now requires most control panels to be marked with their short-circuit current rating (SCCR). This change affects all industrial control


    Original
    UL508A UL508A, Short Circuit Current Ratings & Solid State Relays NEC RELAY DE PDF

    NZMN1-M80

    Abstract: IEC 60947-4-1 EN 60947-4-1 IEC/EN 60947 IEC/EN 60947-4-1 VDE 0660 motor protective relays MOELLER moeller DILM80 dilm80 IEC 60947 VDE 0660 NFEN60947-2
    Text: Type: NZMN1−M80 Article No.: 265721 Sales text Circuit−breaker 3p 80A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 63.80 Short−circuit release 640.1120 Contactor type “1” coordination


    Original
    NZMN1-M80 DILM80( D-53115 HPL-C2007G NZMN1-M80 IEC 60947-4-1 EN 60947-4-1 IEC/EN 60947 IEC/EN 60947-4-1 VDE 0660 motor protective relays MOELLER moeller DILM80 dilm80 IEC 60947 VDE 0660 NFEN60947-2 PDF

    NZMN1-M100

    Abstract: Moeller DILM95 DILM115 IEC/EN 60947-4-1 motor protective relays MOELLER IEC/EN 60947 VDE 0660 IEC 60947-4-1 motor protective MOELLER IEC 60947 VDE 0660 NFEN60947-2
    Text: Type: NZMN1−M100 Article No.: 265722 Sales text Circuit−breaker 3p 100A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 80.100 Short−circuit release 800.1250 Contactor type “1” coordination


    Original
    NZMN1-M100 DILM95( DILM115( D-53115 HPL-C2007G NZMN1-M100 Moeller DILM95 DILM115 IEC/EN 60947-4-1 motor protective relays MOELLER IEC/EN 60947 VDE 0660 IEC 60947-4-1 motor protective MOELLER IEC 60947 VDE 0660 NFEN60947-2 PDF

    NZMN1-M63

    Abstract: IEC/EN 60947-4-1 IEC/EN 60947 dilm65 EN 60947-4-1 IEC 60947-4-1 circuit breaker VDE 0660 motor protective relays MOELLER IEC 60947 VDE 0660
    Text: Type: NZMN1−M63 Article No.: 265720 Sales text Circuit−breaker 3p 63A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 50.63 Short−circuit release 504.882 Contactor type “1” coordination


    Original
    NZMN1-M63 DILM65( DILM80( D-53115 HPL-C2007G NZMN1-M63 IEC/EN 60947-4-1 IEC/EN 60947 dilm65 EN 60947-4-1 IEC 60947-4-1 circuit breaker VDE 0660 motor protective relays MOELLER IEC 60947 VDE 0660 PDF

    telemecanique lc1d09

    Abstract: allen bradley 100-c43 telemecanique contactor LC1D80 LC1-D09 telemecanique contactor LC1D12 telemecanique contactor catalogue allen bradley 100-c30 telemecanique LC1D40 allen bradley 100-c23 LC1-D12
    Text: Allen Bradley NEMA Motor Starters and Ferraz Shawmut Fuses Type 2 Protection Achieving Type 2 “No Damage” Motor Start Protection Type 2 “No Damage” Protection - What Is It and Which Fuses Are Best? Type 2 protection, also referred to as “no damage” protection, simply means that if a short circuit occurs, the short circuit protective device


    Original
    SG01V02SY500 A6D400R AJT400 A6D350R AJT300 telemecanique lc1d09 allen bradley 100-c43 telemecanique contactor LC1D80 LC1-D09 telemecanique contactor LC1D12 telemecanique contactor catalogue allen bradley 100-c30 telemecanique LC1D40 allen bradley 100-c23 LC1-D12 PDF

    diode m5p

    Abstract: switch transistor pnp or npn NPN switching power transistor npn transistor 70 volt IA 05 IA05BSF m5x0.5 DIMENSIONS transistor BSF
    Text: y ant r r a sw r a e 5y Proximity Sensors Inductive Short body, Stainless Steel Housing Types IA, M5 w/short-circuit protection • Miniature stainless steel housing M5 • Short body • Sensing distance: 1.0 mm • Power supply: 10 to 30 VDC • Output: Transistor NPN/PNP, make or break switching


    Original
    PDF

    DILM185

    Abstract: DILM225 NZMN2-M200 Moeller DILM 22 IEC 60947-4-1 EN 60947-4-1 DILM185/22 IEC/EN 60947 VDE 0660 fuse breaker VDE 0660
    Text: Type: NZMN2−M200 Article No.: 265725 Sales text Circuit−breaker 3p 200A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 160.200 Short−circuit release 1600.2500


    Original
    NZMN2-M200 DILM185/22( DILM225/22( D-53115 HPL-C2007G DILM185 DILM225 NZMN2-M200 Moeller DILM 22 IEC 60947-4-1 EN 60947-4-1 DILM185/22 IEC/EN 60947 VDE 0660 fuse breaker VDE 0660 PDF

    NZMN2-M160

    Abstract: Moeller NZMN2-M160 IEC 60947-4-1 IEC/EN 60947 motor protective relays MOELLER VDE 0660 EN 60947-4-1 m160 IEC/EN 60947-4-1 circuit-breakers
    Text: Type: NZMN2−M160 Article No.: 265724 Sales text Circuit−breaker 3p 160A motor protection Ordering information Motor ratings Rated short−circuit current 500 V/525 V Iq kA 50 Setting range Overload releases 125.160 Short−circuit release 1280.2240


    Original
    NZMN2-M160 DILM150( DILM80( D-53115 HPL-C2007G NZMN2-M160 Moeller NZMN2-M160 IEC 60947-4-1 IEC/EN 60947 motor protective relays MOELLER VDE 0660 EN 60947-4-1 m160 IEC/EN 60947-4-1 circuit-breakers PDF

    S800-SOR

    Abstract: S800S-UC S803-BB250 IEC 60947-2 ABB 60947-2 MAX EARTH LOOP IMPEDANCE mcb tripping curves ABB DC Main Circuit breaker 2POLE A9-30-10 S500HV S803S-B32
    Text: Technical catalogue 2010 S800/S500 The High Performance MCB High performance MCB S800 and S500 The S800 and S500 high performance circuit breakers are miniature circuit breakers that restrict current and energy. The maximum rated ultimate short-circuit breaking capacity


    Original
    S800/S500 2CCC413003C0201 S800-SOR S800S-UC S803-BB250 IEC 60947-2 ABB 60947-2 MAX EARTH LOOP IMPEDANCE mcb tripping curves ABB DC Main Circuit breaker 2POLE A9-30-10 S500HV S803S-B32 PDF

    IEC en 61095 ct

    Abstract: A9C15185
    Text: Fiche produit Caractéristiques A9C15185 contactor CT - 2 NO - 20 A - 230 V AC Contactor application Control circuit Range of product CT Device short name CT Poles description 2P Pole contact composition 2 NO Network type AC Control type Remote control Control circuit voltage


    Original
    A9C15185 IEC en 61095 ct A9C15185 PDF

    wiring diagram ABB motor starter

    Abstract: IEC 60947-4-1 for ABB IEC 60947-2 ABB 1SAM250000R1009 MS116 1SAM250000R1005 IEC 60947-4-1 abb 1SAM250000R1003 2CDC131025D0201 1SAM250000R1002
    Text: Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures.


    Original
    MS116 D0201 wiring diagram ABB motor starter IEC 60947-4-1 for ABB IEC 60947-2 ABB 1SAM250000R1009 MS116 1SAM250000R1005 IEC 60947-4-1 abb 1SAM250000R1003 2CDC131025D0201 1SAM250000R1002 PDF

    wiring diagram ABB motor starter

    Abstract: IEC 60947-4-1 for ABB 1SAM350000R1011 IEC 60947-2 ABB MS132-12 1SAM350000R1014 MS132-32 IEC 60947-2 1SAM350000R1005 MS132-0
    Text: Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures.


    Original
    MS132 D0201 wiring diagram ABB motor starter IEC 60947-4-1 for ABB 1SAM350000R1011 IEC 60947-2 ABB MS132-12 1SAM350000R1014 MS132-32 IEC 60947-2 1SAM350000R1005 MS132-0 PDF

    IA06BSF10NO

    Abstract: IA06BSF10NC IA06BSF10NCM5 IA06BSF10NOM5 IA06BSF10PO IA06BSF10POM5 IA06BSN20NC IA06BSN20NCM5 IA06BSN20NO IA06BSN20NOM5
    Text: Proximity Sensors Inductive Stainless Steel Housing Types IA, Ø6.5 • Miniature Ø6.5 stainless steel housing • Short housing • Sensing distance: 1.0 and 2.0 mm • Power supply: 10 to 30 VDC • Output: Transistor NPN/PNP, make or break switching • Protection: Short-circuit, reverse polarity and transients


    Original
    PDF

    46433

    Abstract: C3M11 3 phase BUSBAR 690v 100ka C312 C350H protectiondegreeIP55 690v Electrical motor DIN 2510 C3-12
    Text: Motor Circuit Breakers C3 Farnell Codes: 5020499 - 5020839 ❚ Motor protection rating up to 100 Amps ❚ Short circuit breaking capacity up to 100kA ❚ Phase failure protection ❚ DIN rail mounting ❚ Wide range of accessories Options and ordering codes


    Original
    100kA C3/12 C3/12-0 -C3/12-0 46433 C3M11 3 phase BUSBAR 690v 100ka C312 C350H protectiondegreeIP55 690v Electrical motor DIN 2510 C3-12 PDF

    ZB12-16

    Abstract: ZB12-12 ZB12 dilm contactors
    Text: ZB12-16 Part ZB12-16 Adjustable Range 12 - 16 Short Circuit Protection Max 600 VAC Auxiliary Contacts Normally Open Normally Closed Fuses (A) Circuit Breaker (A) 1 1 60 25 (ZB12-12 shown, actual part may vary) Other ZB12 products include: ZB12 Accessories


    Original
    ZB12-16 ZB12-12 ZB12-16 ZB12 dilm contactors PDF

    CAD-50

    Abstract: DC-13 IEC 60947-5-1 ip 67 CAD50EL DC 3 DUTY CONTACTOR
    Text: Product data sheet Characteristics CAD50EL contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 48 V DC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    CAD50EL CAD-50 DC-13 DC-13 IEC 60947-5-1 ip 67 CAD50EL DC 3 DUTY CONTACTOR PDF

    CAD50FD

    Abstract: DC-13 cad-50 VDE0660
    Text: Product data sheet Characteristics CAD50FD contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 110 V DC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    CAD50FD CAD-50 DC-13 CAD50FD DC-13 VDE0660 PDF

    DC-13

    Abstract: CAD-50 690VDC
    Text: Product data sheet Characteristics CAD50JL contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 12 V DC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    CAD50JL CAD-50 DC-13 DC-13 690VDC PDF

    CAD50M7

    Abstract: CAD-50 bs4794
    Text: Product data sheet Characteristics CAD50M7 contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 220 V AC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    CAD50M7 CAD-50 AC-14 AC-15 CAD50M7 bs4794 PDF

    CAD50N7

    Abstract: CAD-50 TESYS Schneider POLE CONTACT RESISTANCE
    Text: Product data sheet Characteristics CAD50N7 contactor TeSys CAD-50 - 5 NO instantaneous - 10 A - 415 V AC Range of product TeSys D Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit Utilisation category


    Original
    CAD50N7 CAD-50 AC-14 AC-15 CAD50N7 TESYS Schneider POLE CONTACT RESISTANCE PDF