Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TESYS SCHNEIDER RELAY Search Results

    TESYS SCHNEIDER RELAY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UHD432R/B Rochester Electronics LLC UHD432 - Quad 2-Input NOR Power/Relay Driver Visit Rochester Electronics LLC Buy
    PS7360L-1A-V-A Renesas Electronics Corporation 6-Pin Dip, High Isolation Voltage Visit Renesas Electronics Corporation
    PS7360L-1A-V-E3-A Renesas Electronics Corporation 6-Pin Dip, High Isolation Voltage Visit Renesas Electronics Corporation
    PS7360-1A-V-A Renesas Electronics Corporation 6-Pin Dip, High Isolation Voltage Visit Renesas Electronics Corporation
    DRV777DR Texas Instruments 7-bit Integrated Motor and Relay Driver 16-SOIC -40 to 125 Visit Texas Instruments Buy

    TESYS SCHNEIDER RELAY Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    LA6DK10

    Abstract: lad6k10 LA1-DX20 LADR4 LA6-DK10 LADC223 LADN11 LAD-6K10 schneider CAD-32 CA2SK
    Text: IEC Type Industrial Control Relays TeSys D-Line, K-Line, and SK-Line Class 8501 CONTENTS Schneider Electric Brands Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2


    Original
    1-888-SquareD 8501CT0101 LA6DK10 lad6k10 LA1-DX20 LADR4 LA6-DK10 LADC223 LADN11 LAD-6K10 schneider CAD-32 CA2SK PDF

    schneider GV2

    Abstract: schneider GV2RT 150 KW motor types GV2, GV3 and GV7 TeSys GV2L schneider overload gv2 GV2ME 4.6 KW motor schneider GV2ME circuit-breakers
    Text: Chapter 3: Contents Schneider Electric TeSys motor circuit-breakers Selection guide: Thermal-magnetic motor circuit-breakers pages 3/2 and 3/3 Selection guide: Magnetic motor circuit-breakers pages 3/4 and 3/5 Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7


    Original
    PDF

    schneider GV2ME

    Abstract: TeSys GV2L LRD-33 GV7-RE220 LRD schneider relay LRD33 GV2-ME07 GV2-L32 LRD-33 tripping curve GV7-RS100
    Text: Curves TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P Thermal-magnetic tripping curves for GV2-ME and GV2-P Average operating time at 20 °C according to multiples of the setting current Time s 10 000 1000 100


    Original
    PDF

    schneider LRD 08

    Abstract: LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21
    Text: 24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,


    Original
    LRD-01. LRD-3322. LR9-D67 LR9-D69 schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LC1-D09 schneider overload relay schneider LC1-D09 LRD-21 PDF

    LU9 gc3

    Abstract: LB920 schneider GV2 LA9LB920 schneider GV2 L GV1 G09 Schneider Electric lub lu2b Gv2 overload xzmc11
    Text: TeSys Model U Curves Starter-controllers Tripping curves for control units LUCA, LUCB, LUCD Time s Average operating times at 20 ˚C according to multiples of the setting current, tolerance : ± 20 %. 1000 1 100 2 3 10 1 0,1 1 2 3 4 5 6 7 8 10 12 14 20 30


    Original
    PDF

    LC1 D32 wiring diagram

    Abstract: schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram
    Text: Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,


    Original
    MKTED205103EN LC1 D32 wiring diagram schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload schneider thermal overload relay lrd 32 LC1 d32 contactor diagram schneider electric LC1 D25 LA7 D09 LRD 14 LC1 d150 wiring diagram PDF

    LC1-D50A

    Abstract: LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12
    Text: Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility . so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify


    Original
    LC1-F630, F6304 LC1-F500 F5004 LC1-F400 F4004 LC1-D50A LC1D40A schneider LC1-D09 LC1-DWK12 LC1D65A LC1-D09 LAD4TBDL LC1-D18 LC1-D09 installation manual LC1-D12 PDF

    60947-2 MAX EARTH LOOP IMPEDANCE

    Abstract: NS160N ns100n GV2-L20 GV2-ME14 GV2-L14 gv2-l16 GV2-L08 LR2-D1308 GV2-L07
    Text: 3/02-03 Page 3 Monday, October 29, 2001 10:37 AM Presentation TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically


    Original
    PDF

    LA9LB920

    Abstract: SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01
    Text: Characteristics TeSys protection components Thermal-magnetic motor circuit-breakers Environment Circuit-breaker type GV2-ME Conforming to standards EN 60947-1, 947-2, 947-4-1, EN 60204, UL 508, CSA C22-2 n° 14, NF C 63-650, 63-120, 79-130, VDE 0113, 0660


    Original
    C22-2 GV2-M/01: LA9-LB920 LA9LB920 SCHNEIDER MOTOR PROTECTION circuit breaker IEC 439-1 LA9-LB920 GV3-ME40 GK3EF40 GV3-A03 GV3A01 schneider GV2ME GV3-A01 PDF

    LC1-D150

    Abstract: bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1
    Text: 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui


    Original
    LC1LC1D09. LC1D40 LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D150 bs 5424 schneider LC1-D09 schneider LC1-D09 LC1-D40 LC1 Schneider VDE 0660 BS 5424 lad6k10 LA4 dfb IEC 60947-5-1 PDF

    LA9LB920

    Abstract: GV3-ME40 GV2-RT08 GK3EF40 schneider GV2ME GV-AE113 GK3EF65 schneider LRD-14 GV2-L32 LC1k schneider
    Text: Presentation TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC 947-2 and IEC 947-4-1.


    Original
    GV7-V01 LA9LB920 GV3-ME40 GV2-RT08 GK3EF40 schneider GV2ME GV-AE113 GK3EF65 schneider LRD-14 GV2-L32 LC1k schneider PDF

    Schneider NS 800

    Abstract: LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter
    Text: TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection equipment protection only Protection against phase imbalance


    Original
    AP00r AP11r AP12r Schneider NS 800 LUA1C110 LB920 LUCA 1XBL schneider thermal overload relay schneider GV2 LA9LB920 Schneider Electric lub LUB320 schneider motor starter PDF

    telemecanique LC1 f400

    Abstract: NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H
    Text: Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss


    Original
    AC-15 DC-13 telemecanique LC1 f400 NS630H NS400H NS250H c1001 merlin gerin NS80H Telemecanique LC1 EC 19 lc1 f265 telemecanique magnetic contactor NS160H PDF

    LC1-D09

    Abstract: schneider LC1-D09 LC1-D40 LC1 d12008 contactor LC1 D25004 LC1 D25008 LC1-D25 LC1-D65004 LC1-D80 LC1-D80004
    Text: 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 3-pole LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4


    Original
    LC1-D09. LC1-D25. LC1-DT20. LC2-DT20. 21/NC 13/NO LC1-D09 schneider LC1-D09 LC1-D40 LC1 d12008 contactor LC1 D25004 LC1 D25008 LC1-D25 LC1-D65004 LC1-D80 LC1-D80004 PDF

    LC1-D09

    Abstract: LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10
    Text: Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage Ui Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,


    Original
    LC1LC1LC1D09. LC1D50. LC1-D115 LC1-D150 LC1-D09. LC1-D80 LC1-D40. LC1-D09 LC1-D150 lad6k10 schneider LC1-D09 bs 5424 schneider schneider LC1-D LC1 Schneider LC1-D115 LC1-D09 diagram LA6DK10 PDF

    CA2SK20

    Abstract: CA2SK11 CA3SK20 CA3SK11 CA2SK VDE0660 LA1-SK20 IEC337 bs4794 LA1-SK11
    Text: IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line SK-Line Ordering Information SK-Line Ordering Information – Miniature size saves space – Mounts on 35mm DIN3 track or can be mounted directly to a panel – Up to 4 poles Contact Configuration


    Original
    CA2SK20 CA3SK11 CA2SK11 CA3SK20 CAZSK11G7 CA2SK20 CA2SK11 CA3SK20 CA3SK11 CA2SK VDE0660 LA1-SK20 IEC337 bs4794 LA1-SK11 PDF

    LC1-DT40

    Abstract: LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004
    Text: References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors


    Original
    LC1-D09. LA9-D6569 LA9-D4002 LA9-D8069 LA9-D8002 LA9-D92 LA9-D93 LC1-DT40 LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004 PDF

    schneider LC1-D09 wiring diagram

    Abstract: LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12
    Text: Motor control Accurate and reliable control of motors Te Sys range provide you more simplicity, compactness, openness and flexibility . so man y evolutions and new items to aid your productivity. Search By Part Number TeSys For a new start! A range of simple,


    Original
    9422CLA50 9422CLA51 9422CLA10 9422CLA11 9422CSF30 9422CSF50 9422CSF70 9422CSF10 9422CSF304 9422CSF504 schneider LC1-D09 wiring diagram LC1-D38 LC1-D18 LT6P0M005FM LC2K06 LC1-D09 installation manual LC1K0910BD 8502CT9901 LC1K0910P7 LC1-D12 PDF

    IEC 60947 VDE 0660

    Abstract: No abstract text available
    Text: Product data sheet Characteristics CA3KN22BD TeSys K control relay - 2 NO + 2 NC - <= 690 V - 24 V DC standard coil Product availability: Stock - Normally stocked in distribution facility Commercial Status Commercialised Range of product TeSys K control relay


    Original
    CA3KN22BD AC-15 DC-13 IEC 60947 VDE 0660 PDF

    CAD50G7

    Abstract: control relay CAD-50 contactor relay 5 V coil CAD50
    Text: Product data sheet Characteristics CAD50G7 contactor TeSys K, D, S - CAD-50 - 5 NO + 0 NC - instantaneous - 10 A - 120 V AC Range of product TeSys D control relay Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit


    Original
    CAD50G7 CAD-50 AC-14 AC-15 CAD50G7 control relay contactor relay 5 V coil CAD50 PDF

    bs 5424 schneider

    Abstract: VDE 0660 BS 5424 BS 5424 CA3KN31FD electromagnetic relay bs5424 schneider bs 5424 bs 5424 schneider VDE 0660 IEC 60947 VDE 0660 CA3-KN31
    Text: Product data sheet Characteristics CA3KN31FD contactor TeSys CA3-K - 3 NO + 1 NC instantaneous - 10 A - 110 V DC Range of product TeSys k control relay Product or component type Electromagnetic relay Device short name CA3K Contactor application Control circuit


    Original
    CA3KN31FD DC-13 bs 5424 schneider VDE 0660 BS 5424 BS 5424 CA3KN31FD electromagnetic relay bs5424 schneider bs 5424 bs 5424 schneider VDE 0660 IEC 60947 VDE 0660 CA3-KN31 PDF

    CAD50S7

    Abstract: relay tesys control relay CAD-50 contactor relay 5 V coil TeSys schneider relay
    Text: Product data sheet Characteristics CAD50S7 contactor TeSys K, D, S - CAD-50 - 5 NO + 0 NC - instantaneous - 10 A - 500 V AC Range of product TeSys D control relay Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit


    Original
    CAD50S7 CAD-50 AC-14 AC-15 CAD50S7 relay tesys control relay contactor relay 5 V coil TeSys schneider relay PDF

    CAD50T7

    Abstract: CAD-50
    Text: Product data sheet Characteristics CAD50T7 contactor TeSys K, D, S - CAD-50 - 5 NO + 0 NC - instantaneous - 10 A - 480 V AC Range of product TeSys D control relay Product or component type Auxiliary contactor Device short name CAD Contactor application Control circuit


    Original
    CAD50T7 CAD-50 AC-14 AC-15 CAD50T7 PDF

    bs 5424 schneider

    Abstract: CA3KN31GD bs 5424 schneider VDE 0660 IEC 60947 VDE 0660 schneider bs 5424 electromagnetic relay bs 5424 bs5424 VDE 0660 BS 5424 control relay
    Text: Product data sheet Characteristics CA3KN31GD contactor TeSys CA3-K - 3 NO + 1 NC instantaneous - 10 A - 125 V DC Range of product TeSys k control relay Product or component type Electromagnetic relay Device short name CA3K Contactor application Control circuit


    Original
    CA3KN31GD DC-13 bs 5424 schneider CA3KN31GD bs 5424 schneider VDE 0660 IEC 60947 VDE 0660 schneider bs 5424 electromagnetic relay bs 5424 bs5424 VDE 0660 BS 5424 control relay PDF