Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    THERMOFLEX CABLES Search Results

    THERMOFLEX CABLES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-SFPP2EPASS-005 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-005 5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (16.4 ft) Datasheet
    SF-SFPP2EPASS-001 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-001 1m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (3.3 ft) Datasheet
    AV-DPMDPM0000-001 Amphenol Cables on Demand Amphenol AV-DPMDPM0000-001 1m DisplayPort Cable - Amphenol DisplayPort 1.1 Certified Cable (3.3ft) 1m (3.3') Datasheet
    SF-SFPP2EPASS-007 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-007 7m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (23 ft) Datasheet
    SF-SFPP2EPASS-002 Amphenol Cables on Demand Amphenol SF-SFPP2EPASS-002 2m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (6.6 ft) Datasheet

    THERMOFLEX CABLES Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    thermoflex cables

    Abstract: No abstract text available
    Text: Cable Assemblies Defining Low Loss and other Cable Assemblies Low Loss - High Performance • • • • Six Low Loss Cable options Wide Connector Selection Phase Matching available Crush Proof Armored Protection options Midwest Microwave offers six types of low loss and ultra low loss


    Original
    PDF MIL-C-17 18GHz thermoflex cables

    IPC-FC-221

    Abstract: ptfe tape Midwest Microwave M52 Midwest Microwave M42 Midwest Microwave M42 power MIL-C-17
    Text: Cable Assemblies • • • • • • General Information Low Loss and Ultra-Low Loss Flexible Cable Assemblies Semi-Flexible and Semi-Rigid Cable Assemblies Phase and Temperature Stable Ruggedized or Armored Abrasion Resistant Construction Available Meets MIL-E-5400 and MIL-16400 Environmental Requirements


    Original
    PDF MIL-E-5400 MIL-16400 ASTM-B-298 MIL-C-17. IPC-FC-221 ASTM-B-298. MIL-C-17, ptfe tape Midwest Microwave M52 Midwest Microwave M42 Midwest Microwave M42 power MIL-C-17

    IEC 947 EN 60947

    Abstract: EN 60947-1/2 LED Lamp 1W RJ12 socket thermoflex 901-030 EN 60947-5-5 IEC 60947-5-5 DC-13 RJ12
    Text: RAFIX 22 QR 2 General data RAFIX 22QR control component range • For a mounting hole diameter of 22.3 mm to IEC 60947 • 250V/10A max. • Water-jet proof IP65 • 2 collar shapes • The lamps of the pushbuttons can also be replaced from the front • The contact blocks silver or gold contacts snap onto the actuators with a coupling


    Original
    PDF 50V/10A M20x1 M25x1 IEC 947 EN 60947 EN 60947-1/2 LED Lamp 1W RJ12 socket thermoflex 901-030 EN 60947-5-5 IEC 60947-5-5 DC-13 RJ12

    MCC panel design

    Abstract: IEC960947-5-1 RJ12
    Text: RAFIX 22 QR 2 General data RAFIX 22QR control component range • For a mounting hole diameter of 22.3 mm to IEC 60947 • 250V/10A max. • Water-jet proof IP65 • 2 collar shapes • The lamps of the pushbuttons can also be replaced from the front • The contact blocks silver or gold contacts snap onto the actuators with a coupling


    Original
    PDF 50V/10A M20x1 M25x1 MCC panel design IEC960947-5-1 RJ12

    Untitled

    Abstract: No abstract text available
    Text: Cable Assemblies Definition of Parameters Impedance - The characteristic impedance equation for a coaxial transmission line is expressed as follows: Impedance ≡ Zo = where: 138.06 √ ε Log 10 D/d D = diameter of outer conductor d = diameter of center conductor


    Original
    PDF

    IEC 947 EN 60947

    Abstract: MCC panel design buzzer panel DC-13 Q300 RJ12 1302401 VDE 0660 - 107 Sonic Drive
    Text: RAFIX 22 QR 2 General data RAFIX 22QR control component range • For a mounting hole diameter of 22.3 mm to IEC 60947 • 250V/10A max. • Water-jet proof IP65 • 2 collar shapes • The lamps of the pushbuttons can also be replaced from the front • The contact blocks silver or gold contacts snap onto the actuators with a coupling


    Original
    PDF 50V/10A IEC 947 EN 60947 MCC panel design buzzer panel DC-13 Q300 RJ12 1302401 VDE 0660 - 107 Sonic Drive

    din 42802

    Abstract: grote hartmann grote hartmann connectors LS205-L KT218-H 416016 MPS OUTSIDE BOX PACKING SPECIFICATION PS 2251-07 22-1-044 LK410
    Text: Multi-Contact Connectors and Accessories ø 0.5 mm - ø 4 mm Connecting Leads, Plugs, Sockets, Adapters Lab1-4 ® With this Lab 1-4 catalogue we present the complete MC® range of connectors for voltages up to max. 30 VAC / 60 VDC. With our proven Multilam technology and high-quality electroplating,


    Original
    PDF

    Midwest Microwave M52

    Abstract: No abstract text available
    Text: Low Loss_ Cable Characteristics Cable Assemblies High Performance Cable Assemblies •Ultra-Low Insertion Loss • DC - 26.5 GHz Performance ■Phase and Temperature Stable ■Highly Flexible Ultra Low Loss Cable M-38 0.145 Dia M-54 0.240 Dia M-82 0.325 Dia


    OCR Scan
    PDF 50GHz. Midwest Microwave M52

    Untitled

    Abstract: No abstract text available
    Text: Defining Low Loss and other Cable Assemblies Cable Assemblies Low Loss - High Performance Six Low Loss Cable options • Wide Connector Selection ■ Phase Matching available ■ Crush Proof Armored Protection options ■ Midwest Microwave offers six types of low loss and ultra low loss


    OCR Scan
    PDF MIL-C-17 18GHz

    Untitled

    Abstract: No abstract text available
    Text: Defining Low Loss and other Cable Assemblies Cable Assemblies Low Loss - High Performance • Six Low Loss Cable options ■ Wide Connector Selection ■ Phase Matching available ■ Crush Proof Armored Protection options Midwest Microwave offers six types of low loss and ultra low loss


    OCR Scan
    PDF MIL-C-17 18GHz

    Untitled

    Abstract: No abstract text available
    Text: Multi-C onta ct 3. L itz e n le itu n g e n W ir e s M u lt is t r a n d C a b le s Litzenleitungen M u ltistran d w ires Cables Bei den im folgenden aufgefuhrten Litzenlei­ tungen handelt es sich um hochflexible Leitungen m it C u-D rahtlitzenleiter aus verseilten


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Cable Assemblies Definition of Parameters Impedance - The characteristic impedance equation for a coaxial transmission line is expressed as follows: 138.06 Impedance = Zo= - — - \e where: Log 10 D/d D = diameter of outer conductor d = diameter of center conductor


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Cable Assemblies Definition of Parameters Impedance - The characteristic impedance equation for a coaxial transmission line is expressed as follows: 138.06 Im p e d a n c e where: = Z o= - - — - L o g 10 D /d D = diam eter of outer conductor


    OCR Scan
    PDF

    Midwest Microwave M52

    Abstract: Semi-Rigid 141 cable MIL-16400 MIL-T-81490 thermoflex
    Text: Cable Assemblies • • • • • • General Information Low Loss and Ultra-Low Loss Flexible Cable Assemblies Semi-Flexible and Semi-Rigid Cable Assemblies Phase and Temperature Stable Ruggedized or Armored Abrasion Resistant Construction Available Meets MIL-E-5400 and MIL-16400 Environmental Requirements


    OCR Scan
    PDF MIL-E-5400 MIL-16400 Midwest Microwave M52 Semi-Rigid 141 cable MIL-T-81490 thermoflex