Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    UNBALANCE LOAD, POWER LOSS Search Results

    UNBALANCE LOAD, POWER LOSS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TPD4164F Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=2A/ Surface mount type / HSSOP31 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4164K Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=2A/ Through hole type / HDIP30 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4163K Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=1A/ Through hole type / HDIP30 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4163F Toshiba Electronic Devices & Storage Corporation Intelligent power device / VBB=600V / Iout=1A/ Surface mount type / HSSOP31 Visit Toshiba Electronic Devices & Storage Corporation
    TPD4207F Toshiba Electronic Devices & Storage Corporation Intelligent power device 600V (High voltage PWM DC brushless motor driver) Visit Toshiba Electronic Devices & Storage Corporation

    UNBALANCE LOAD, POWER LOSS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Mini-Circuits - Specification for Power Splitter - PSC-4-1 Power Splitter Notes: • Internal load dissipation: 0.25 Watt. • Matched power rating: 1 Watt. • For Insertion Loss Max. L and Amplitude Unbalance Max. (L): Adjacent Ports, 25°C. • General Quality Control Procedures and Environmental Specifications are given in Mini-Circuits Guarantees Quality.


    Original
    PDF

    monitoring relay cm-pas

    Abstract: 3 phase monitor Federal Isolating Switch F0512A F018 LED monitor circuit diagram DC-12 DC-13 F0004 R0100
    Text: Measuring and monitoring relay CM-PAS Three-phase monitor for phase unbalance Data sheet 2CDC 251 050 F0004 Features ᕄ ᕅ ᕃ ᕆ ᕇ ½ ½ ½ ½ ½ ½ ½ Three-phase monitoring of phase sequence, phase loss and phase unbalance Adjustable unbalance threshold


    Original
    PDF F0004 F0188 F0003 F0182 F0179 F0181 D0201 monitoring relay cm-pas 3 phase monitor Federal Isolating Switch F0512A F018 LED monitor circuit diagram DC-12 DC-13 F0004 R0100

    IRF9460

    Abstract: irfp460 ir2110 mosfet IRF450 IR2110 dc motor ir2110 class d amp ir2110 with calculations for 3 phase inverter ir2110 with calculations for inverter irfp460 inverter IR2110 buck Class d IR2110
    Text: Index INT990 Application Characterization of IGBTs HEXFRED is a trademark of International Rectifier Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature


    Original
    PDF INT990 INT-983, IRF9460 irfp460 ir2110 mosfet IRF450 IR2110 dc motor ir2110 class d amp ir2110 with calculations for 3 phase inverter ir2110 with calculations for inverter irfp460 inverter IR2110 buck Class d IR2110

    MOSFET 4407

    Abstract: IRF9460 ir2110 class d amp irfp460 ir2110 AN-941 IRFP450 inverter irfp450 mosfet full bridge ir2110 with calculations for inverter full bridge ir2110 4407 mosfet
    Text: INT990 Application Characterization of IGBTs HEXFRED is a trademark of International Rectifier Topics Covered: Gate drive for IGBTs Safe Operating Area Conduction losses Statistical models Switching losses Device selection and optimization Spreadsheets to calculate power losses and junction temperature


    Original
    PDF INT990 INT-983, MOSFET 4407 IRF9460 ir2110 class d amp irfp460 ir2110 AN-941 IRFP450 inverter irfp450 mosfet full bridge ir2110 with calculations for inverter full bridge ir2110 4407 mosfet

    IRF9460

    Abstract: ir2110 spice IR2110 IGBT DRIVER irfp460 ir2110 INT-983 IRGP50S ir2110 with calculations for 3 phase inverter IR2121 irfp450 mosfet IRCPC50F
    Text: Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements . 1 I. A Impact of the impedance of the gate drive circuit on switching losses. 1


    Original
    PDF AN-990 IRF9460 ir2110 spice IR2110 IGBT DRIVER irfp460 ir2110 INT-983 IRGP50S ir2110 with calculations for 3 phase inverter IR2121 irfp450 mosfet IRCPC50F

    loss of neutral monitor

    Abstract: F0003 CM-MPS LED monitor circuit diagram R0100 R1300 3 phase monitoring relays 60947-5-1 abb heidelberg circuit R3300
    Text: Measuring and monitoring relays CM-MPS Multifunctional three-phase monitor Data sheet 2CDC 251 005 F0003 Features ᕆ ᕄ ᕅ ᕃ ᕇ ᕉ ᕈ ½ ½ ½ ½ ½ ½ ½ ½ ½ Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance


    Original
    PDF F0003 voltag185 F0189 F0188 F0182 F0179 D0201 F0181 loss of neutral monitor F0003 CM-MPS LED monitor circuit diagram R0100 R1300 3 phase monitoring relays 60947-5-1 abb heidelberg circuit R3300

    Untitled

    Abstract: No abstract text available
    Text: The PMP Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMPU is a universal voltage product that works on any three-phase system voltage from 208-480V a separate 120V


    Original
    PDF 08-480V 08480V 08-480V 100ms E109466 EN60947-1, EN60947-5-1

    APMR0096

    Abstract: 480 v reverse phasing wire diagram E137808 Schaffner catalog 28B2029-0A0 LFIL0000 ZCAT3035-1330A wye delta start wiring diagram single phase reverse motor wye to delta wiring diagram AC motor
    Text: Bulletin No. APMR-E Drawing No. LP0376 Released 2/07 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL APMR - 3 PHASE FAULT DETECTION DIN RAIL MODULE z PROTECTS AGAINST PHASE LOSS, UNBALANCE, UNDER VOLTAGE, AND PHASE REVERSAL z AVAILABLE IN 230, 380, OR 480 VAC


    Original
    PDF LP0376 E137808 APMR0096 480 v reverse phasing wire diagram E137808 Schaffner catalog 28B2029-0A0 LFIL0000 ZCAT3035-1330A wye delta start wiring diagram single phase reverse motor wye to delta wiring diagram AC motor

    phase failure / phase reversal

    Abstract: wiring diagram motor start delta magnetic Contactor en50022 3 phase monitoring relays 480 v reverse phasing wire diagram phase failure relay ac under voltage relay 3-phase monitor diagram 3 phase heater
    Text: Bulletin No. APMR-B Drawing No. LP0376 Revised 10/00 Tel +1 717 767-6511 Fax +1 (717) 764-6587 www.redlion-controls.com MODEL APMR - 3 PHASE FAULT DETECTION DIN RAIL MODULE ! PROTECTS AGAINST PHASE LOSS, UNBALANCE, UNDER VOLTAGE, AND PHASE REVERSAL ! AVAILABLE IN 230, 380, OR 480 VAC


    Original
    PDF LP0376 E137808 F-77183 phase failure / phase reversal wiring diagram motor start delta magnetic Contactor en50022 3 phase monitoring relays 480 v reverse phasing wire diagram phase failure relay ac under voltage relay 3-phase monitor diagram 3 phase heater

    208-480V

    Abstract: phase sequence indicator EN60947-1 EN60947-5-1 70169-D 120v relay 11 pin diagram three phase sequence 600V-rated unbalance load, power loss
    Text: PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMP Series Plug-in u Universal voltage range of 208-480V on PMPU provides the flexibility to cover a variety of applications with one unit u Protects against phase loss,


    Original
    PDF 08-480V 100ms EN60947-1, EN60947-5-1 E109466 70169-D 208-480V phase sequence indicator EN60947-1 EN60947-5-1 120v relay 11 pin diagram three phase sequence 600V-rated unbalance load, power loss

    EN60947-1

    Abstract: EN60947-5-1 three phase sequence 208-480V phase sequence protection PMD120
    Text: PHASE MONITOR RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over Voltage PMD Series Surface-Mount u Universal voltage range of 208-480V on PMDU provides the flexibility to cover a variety of applications with one unit u Protects against phase loss,


    Original
    PDF 08-480V 150oF) 100ms EN60947-1, EN60947-5-1 E109466 EN60947-1 EN60947-5-1 three phase sequence 208-480V phase sequence protection PMD120

    MOSFET 4407

    Abstract: ir2110 class d amp IRFP450 inverter irfp460 ir2110 Class d IR2110 inverter ic 3524 application ir2110 with calculations for inverter BJT with V-I characteristics INT-983 Inverter IR2110
    Text: Application Note AN-990 Application Characterization of IGBTs Table of Contents Page I. Gate Drive Requirements . 1 I. A Impact of the impedance of the gate drive circuit on switching losses. 1


    Original
    PDF AN-990 MOSFET 4407 ir2110 class d amp IRFP450 inverter irfp460 ir2110 Class d IR2110 inverter ic 3524 application ir2110 with calculations for inverter BJT with V-I characteristics INT-983 Inverter IR2110

    PLMU-11

    Abstract: No abstract text available
    Text: Voltage Monitors PLMU Series The PLMU Series continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Voltage Monitors PLM Series The PLM Series continuously measures the voltage of each of the three phases. The PLM Series uses a microcontroller circuit design that senses undervoltage, voltage unbalance, phase loss, and phase reversal. Protection is assured when


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: The PMD Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMDU is a universal voltage product that works on any three-phase system voltage from 208-480V separate 120V & 575V


    Original
    PDF 08-480V 08480V 08-480V EN60947-1, EN60947-5-1 E109466

    Untitled

    Abstract: No abstract text available
    Text: Voltage Monitors TVW Series Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a microcontroller circuit design that senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Voltage Monitors TVM Series Provides protection for motors and other sensitive loads. Continuously measures the voltage of each of the three phases using a microcomputer circuit design that senses under and overvoltage, voltage unbalance, phase loss, and phase reversal.


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: The PMP-FA Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage, and are compatible with most Wye or Delta systems with no connection to Neutral required. They protect against unbalanced


    Original
    PDF 08-480V E109466 00V-rated 149oF)

    mfr 34078

    Abstract: E5400
    Text: NOTES: 1.0 ELECTRICAL SPECIFICATIONS: 1.1 FREQUENCY RANGE: 0 .5 to 2 .0 GHz 1.2 INSERTION LOSS: 1.0dB MAX. 1.3 ISOLATION: 15dB MIN. 1.4 VSWR: 1.5:1 MAX 1.5 OUTPUT UNBALANCE: AMPLITUDE: 0 .5 d B MAX. PHASE: 5° MAX. 1.6 MAX. INPUT POWER: 5 WATTS WITH OUTPUT LOAD VSWR


    OCR Scan
    PDF PWD-5520-03-SMA-79 mfr 34078 E5400

    Untitled

    Abstract: No abstract text available
    Text: NOTES: 1.0 ELECTRICAL SPECIFICATIONS: 1.1 FREQUENCY RANGE: 46 0 to 2 2 0 0 MHz 1.2 INSERTION LOSS: 0.5dB MAX. 1.3 ISOLATION: 20dB MIN. 1.4 VSWR MAX : 1.25:1 1.5 OUTPUT UNBALANCE: 1.5.1 AMPLITUDE: 0.2dB MAX. 1.5.2 PHASE: 4.0* MAX. 1.6 MAX. INPUT POWER: 3 WATTS WITH OUTPUT LOAD VSWR < 2.0:1


    OCR Scan
    PDF D-5520-02-SM

    Untitled

    Abstract: No abstract text available
    Text: REV. Sta tu s REVISION 06/01/01 YS SURFAC E MOUNT HYBRID TRANSFORMER % A. Electrical specifications @ 25'C 1. Pri source im pedance; 6000 2. Sec load im pedance; 6000 3. MAX output power; —4 5 ~ + 7 d Bm 4. Frequency response; ±0.5, 300Hz to 3.5KHz 5. DC unbalance; 0mA


    OCR Scan
    PDF 300Hz 200Hz 1500Vrms 500Vrms

    HYBRID TRANSFORMER

    Abstract: CSA-C22 TS1104 950-M89
    Text: REV. Sta tu s REVISION 06/01/01 YS SURFAC E MOUNT HYBRID TRANSFORMER % A. Electrical specifications @ 25'C 1. Pri source im pedance; 6000 2. Sec load im pedance; 6000 3. MAX output power; —4 5 ~ + 7 d Bm 4. Frequency response; ±0.5, 300Hz to 3.5KHz 5. DC unbalance; 0mA


    OCR Scan
    PDF 300Hz 200Hz 1500Vrms 500Vrms 300Hz, TS1104, origi271 TS1104 HYBRID TRANSFORMER CSA-C22 950-M89

    Untitled

    Abstract: No abstract text available
    Text: REV. S ta tu s REVISION 0 6 / 1 8 / 9 6 TS A. Electrical specifications @ 25 ° C 1. Pri Source Impedance; 600 0 ±10% 2. Sec Load Impedance; 5 20 0 3. MAX Output Power; 3 dBm (2 mW) 4. Frequency Response; ± 0 .5 dB 3 00 Hz to 3.5 KHz 5. DC Unbalance; 0 mA


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: REV. S ta tu s REVISION 0 6 /1 8 /9 6 TS A. Electrical specifications 25 ° C 1. Pri Source Impedance; 600 0 ± 1 0 % 2. Sec Load Impedance; 520 0 3. MAX Output Power; 3 dBm (2 mW) 4. Frequency Response; ± 0 .5 dB 300 Hz to 3.5 KHz 5. DC Unbalance; 0 mA


    OCR Scan
    PDF