block diagram of suction pump
Abstract: AW101 AW101901 water level control block diagram testomat AW101605 12v dc water pump AW101624 water level alarm circuit applications caco3
Text: Data Sheet Water Hardness Monitor SS/AW100_3 Testomat AW101 Automatic on-line monitoring of residual/total water hardness – ideal for water softening and potable water plants Menu-driven, programmable functions with clear LCD text display – simple operation
|
Original
|
SS/AW100
AW101
500ml
TH2100
TH2250
AW100
SS/AW100
block diagram of suction pump
AW101
AW101901
water level control block diagram
testomat
AW101605
12v dc water pump
AW101624
water level alarm circuit applications
caco3
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TURBINE METERS ߜ For Water Flows from 0.15 to 2600 GPM ߜ Scaled Pulse Output Available for Remote Totalization or Rate Indication ߜ For Hot or Cold Water Applications ߜ Up to ±1.5% of Reading Accuracy For Water Totalization FTB-400O Series 85 $ Basic Unit
|
Original
|
FTB-400O
FTB-4000
FTB-4105P,
|
PDF
|
Water Meter
Abstract: No abstract text available
Text: EnergyMetering Apartment water meters Optionally with pulse-output Fittings meters Flush-mounted meters Surface-mounted meters All that counts. Surface-mounted meters Flush-mounted meters Apartment water meters Dry-dial for cold and warm water, optionally with pulse-output
|
Original
|
D-66121
97A020
Water Meter
|
PDF
|
Untitled
Abstract: No abstract text available
Text: LONG-LIFE WATER METERS For Rate Indication with Pulse Output and Totalization Shown Smaller Than Actual Size Model FTB7115 Shown 585 $ MADE IN USA Model FTB6107-PT Shown 128 $ ߜ For Water Flows from 0.25 to 2500 GPM ߜ All-Plastic Version for DI Water and Select Corrosives
|
Original
|
FTB7115
FTB6107-PT
FTB6000
FTB7000
FTB6720
FTB6730
FTB6740
FTB6760
FTB7160-LPR,
|
PDF
|
turbine
Abstract: FLOW METER turbine orifice flow meter specifications water flow counter qmax Water Meter Turbine Flow meter
Text: Issued March 1997 232-6130 Data Pack G Water meter classification Data Sheet Water meters are primarily classified by size. That is, the nominal diameter of the water meter is matched to the size of the pipe to which it is being connected. However, it should always be confirmed that the expected flow
|
Original
|
|
PDF
|
FTB-1209
Abstract: No abstract text available
Text: TEFLON TURBINE METERS MADE IN USA FTB-1200 $ 1787 Basic Unit ߜ ±1% of Reading Accuracy ߜ All Wetted Parts Including Flowmeter Liner Are Teflon® Recommended for Corrosive Service and Ultra Pure Water Flow Applications ߜ Suitable for Clean Liquid Service
|
Original
|
FTB-1200
10-point
FTB-1211,
FTB-1201,
SYS/FTB-12*
SYS/FTB-1201/FLSC-28,
FTB-1209
|
PDF
|
173940-C
Abstract: 173937-C 173936-C 173939-C Gems Sensors FT-110 series 173934 173936 FT-110 173931 173933-C
Text: Turbine Flow Rate Sensor FT-110 Series Instruction Bulletin No. 173926 Operating and Installation Instructions Prior to installation, confirm system versus sensor specifications and media compatibility of sensor. The system needs to be filtered to 50 microns prior to the sensor, and pulses/water hammer effects should be
|
Original
|
FT-110
173940-C
173937-C
173936-C
173939-C
Gems Sensors FT-110 series
173934
173936
173931
173933-C
|
PDF
|
millenium 3 crouzet user guide
Abstract: AUTOMATIC PLANT IRRIGATION SYSTEM CD12-CD20 millenium 2 crouzet user guide PT1000 NTC TEMPERATURE CHART millenium cd12 3 crouzet Crouzet user manuals millenium 3 crouzet gsm based irrigation system XD10-XD26
Text: • Renewable energies ■ Water treatment ■ Industrial machines www.millenium3.crouzet.com Standard & Custom The right solution - whatever the application! With Millenium 3. The right solution - whatever the application! Our company at a glance ■ Millenium 3 Standard
|
Original
|
|
PDF
|
pelton turbine
Abstract: No abstract text available
Text: LOW FLOW TURBINE METERS MADE IN USA $ 690 NIST ߜ Up to 1⁄2% Rate Accuracy ߜ 5000 psig Rated ߜ For Flows Down to 15 cc/min .004 GPM ߜ Ball Bearings Are Field Replaceable Without Loss of Calibration ߜ Includes 20-Point NIST Certification for Water Model Shown
|
Original
|
20-Point
FTB9500
FLSC-60
FTB9503-MS,
pelton turbine
|
PDF
|
173940-C
Abstract: 173937-C 173939-C Gems Gems Sensors FT-110 series 173934 FLOW METER turbine Flow Sensors 173931 turbine flow meters
Text: Turbine Flow Rate Sensor FT-110 Series - TurboFlow Instruction Bulletin No. 173926 Operating and Installation Instructions Prior to installation, confirm system versus sensor specifications and media compatibility of sensor. The system needs to be filtered to 50 microns prior to the sensor, and pulses/water hammer effects should be
|
Original
|
FT-110
173940-C
173937-C
173939-C
Gems
Gems Sensors FT-110 series
173934
FLOW METER turbine
Flow Sensors
173931
turbine flow meters
|
PDF
|
RS432
Abstract: BS1042 LCD ALPHANUMERIC DISPLAY flowmeter RS-432 ABB MagMaster 320 265v flowmeter magnetic 20VA flow measurement as per BS1042
Text: Data Sheet SS/AQUAP Insertion-Type Electromagnetic Probe Flowmeter Issue 9 Fully submersible, rugged and robust sensor – reliable, maintenance-free operation in arduous environments 'Hot tap' capability – enables installation with no interruption to normal water supply
|
Original
|
|
PDF
|
Water Hammer
Abstract: shaker turbine vibration detector damper
Text: Dr Vibe vibration detector Dr Vibe - Vibration Detector Applications: Low frequency vibration increase indicates system imbalance. The area of detection 0.6 - 2.7g up to 300Hz can indicate instability in process systems such as water hammer, loss or wear of
|
Original
|
300Hz)
0-32V
100mA
Water Hammer
shaker
turbine
vibration detector
damper
|
PDF
|
diesel flow sensor
Abstract: No abstract text available
Text: DISCRIMINATING CONTAINMENT SUMP SENSOR MADE IN USA LVLK300 Series 215 $ Basic Unit Cable Not Included ߜ Conductive Polymer Discriminates Between Hydrocarbons and Other Liquids ߜ Hydrocarbons Detected at Any Point Along the Sensor Length—Even When Floating on Water
|
Original
|
LVLK300
LVLK302
LVLK302
SBG22445
K-110
diesel flow sensor
|
PDF
|
transistor a708
Abstract: No abstract text available
Text: Electronic Flow Meter FM1 Description Micro controller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory pre-set for air and water. rail-mounted version 1
|
Original
|
|
PDF
|
|
intake valve sensor
Abstract: ABB transmitter ask 800 CPT40SG40 CGR100G400 PT100 temperature sensor ABB motor
Text: OIL STEAM COMPRESSED AIR SPECIALIST METERS www.mwatechnology.com g ce GAS ENERGY WATER ELECTRICITY ce Extended product range now available t tradi n en d INDEPENDENT METERING SPECIALISTS years 1993 - 2013 . re ra ti 0 year g2 s n indepen of ing th ep rat b
|
Original
|
|
PDF
|
BMOD0094
Abstract: E075 1007239 harting 09 12 008 3001 wind ultracapacitor maxwell boostcap pacemaker wind pitch CH-1728 S17624PDYT20B
Text: BMOD Energy Series 75V e > Series: Energy BOOSTCAP Ultracapacitor Modules » Low Internal Resistance » High Energy Availability » Low Time Constant 75 Volt Module Features: » 75V Operating Voltage » Over 1M duty cycles » -40° to +65° operations » Water, dust and vibrations resistant
|
Original
|
BMOD0094
CH-1728
E075
1007239
harting 09 12 008 3001
wind ultracapacitor
maxwell boostcap
pacemaker
wind pitch
S17624PDYT20B
|
PDF
|
water solenoid valve
Abstract: CAC407 JIS K 5400 for cutting tool VXE2110-01 VXE2130-01 Z-56 VXE2120-01 VXED2130 VXE2220-03 smc VXd
Text: Energy Saving Type 2 Port Solenoid Valve 1/3 For Air/Water/Oil Power consumption SMC comparison Reduction of ng costs runni Reduction of supply capac r e w i po for facilities ty Reduction of CO2 Reduction of temperature increase New generation valve corresponding to energy-saving needs
|
Original
|
EUS70-36A-UK
SLO-8210
water solenoid valve
CAC407
JIS K 5400 for cutting tool
VXE2110-01
VXE2130-01
Z-56
VXE2120-01
VXED2130
VXE2220-03
smc VXd
|
PDF
|
abb 7601
Abstract: SCHEMAT* PT100 Deutsch Relays IN5406 diode oxygen sensor bypass ph probe PT100 temp coeff of resistance B9303 IN5406 water pH measurement sensor
Text: Operating Instructions pH/Redox ORP Analyzers IM/4600–PH_12 Models 4630 & 4635 (incorporating Water Wash Versions 4631 & 4636) ABB The Company EN ISO 9001:2000 EN 29001 (ISO 9001) GI E D Cert. No. Q 05907 As a part of ABB, a world leader in process automation technology, we offer customers
|
Original
|
IM/4600
abb 7601
SCHEMAT* PT100
Deutsch Relays
IN5406 diode
oxygen sensor bypass
ph probe
PT100 temp coeff of resistance
B9303
IN5406
water pH measurement sensor
|
PDF
|
BMOD0094
Abstract: maxwell boostcap wind ultracapacitor boostcap pacemaker wind pitch CH-1728 P075 S17624 S17624PDYT20B
Text: BMOD Power Series 75V p > Series: Power BOOSTCAP Ultracapacitor Modules » Low Internal Resistance » High Energy Availability » Low Time Constant 75 Volt Module Features: » 75V Operating Voltage » Over 1M duty cycles » -40° to +65° operations » Water, dust and vibrations resistant
|
Original
|
J2380
BMOD0094
CH-1728
maxwell boostcap
wind ultracapacitor
boostcap
pacemaker
wind pitch
P075
S17624
S17624PDYT20B
|
PDF
|
VXZ2240-04
Abstract: VCW20-1-29-1 ISO-6358 VXZ2360 GDM2A VXZ22 FUJI ELECTRIC ISO-8778 din water heater pipe VXZ2240
Text: Zero Differential Pressure Type Pilot Operated 2 Port Solenoid Valve For Air, Water, Oil Reduced power consumption DC spec. 7W VXZ23: 11.5 W → 10.5 W VXZ22: 8 W → New VX Z Series VXZ22/23 CAT.EUS70-31A-UK Solenoid valves for various fluids used in a wide variety of
|
Original
|
VXZ23:
VXZ22:
VXZ22/23
EUS70-31A-UK
UL94V-0
VXZ2240-04
VCW20-1-29-1
ISO-6358
VXZ2360
GDM2A
VXZ22
FUJI ELECTRIC
ISO-8778
din water heater pipe
VXZ2240
|
PDF
|
10a dm hole nv
Abstract: VX3134-02 steam trap ISO-8778 ISO-6358 Mitsubishi Materials Surge Absorber flow control valve actuator T-32-13 VX023N-10 VX3324-02
Text: CAT.EUS70-26 A -UK Direct Operated 3 Port Solenoid Valve For Water, Oil, Steam, Air Reduction of power consumption DC specification 4.5 W 8 W 7 W 11.5 W 10.5 W 6 W New VX 3 Series VX31/32 /33 Reduction of power consumption Improvement of corrosion
|
Original
|
EUS70-26
VX31/32
UL94V-0
SLO-8360
10a dm hole nv
VX3134-02
steam trap
ISO-8778
ISO-6358
Mitsubishi Materials Surge Absorber
flow control valve actuator
T-32-13
VX023N-10
VX3324-02
|
PDF
|
ISO-6358
Abstract: VX232 VX2320-02 VX2120-02 ISO-8778 VX2221 vx2320-03 VX2330-03 VX2231 VX2132-02
Text: CAT.EUS70-23 A -UK Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air New Series VX21/22 /23 Reduction of power consumption DC specification 4.5 W 4. 8 WǞ 7 W 10. 0.5 W 11.5 1.5 W Ǟ 10.5 6 WǞ Low power consumption type: 0. W 0.8 (Held at 24 VDC)
|
Original
|
EUS70-23
VX21/22
UL94V-0
ISO-6358
VX232
VX2320-02
VX2120-02
ISO-8778
VX2221
vx2320-03
VX2330-03
VX2231
VX2132-02
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TURBINE AND PADDLEWHEEL FLOWMETERS Flow Reference Section INTRODUCTION Operation Turbine flowmeters continue to be the most popular way to measure flow electronically in a wide range of industries. A review of the advantages turbine flowmeters have to offer provides insight into
|
Original
|
FP-5000
|
PDF
|
2A125VAC
Abstract: ASQ10410 ABV161040 ABS1410409 AWG18 AWG22 C0920 JISC0920 MATSUSHITA CAP FA SERIES Dc motar
Text: Panasonic ideas for life Turquoise switch series D ata Manual H P Turquoise stroke switch ABJ ABV ABS Turquoise switch series Data Manual AKCT1F12 M a y .'06 01/2007 Matsushita Electric Works, Ltd. water dust gas Turquoise switch is active in place of b For example, ac
|
OCR Scan
|
AKCT1F12
200605-2YD
2A125VAC
ASQ10410
ABV161040
ABS1410409
AWG18
AWG22
C0920
JISC0920
MATSUSHITA CAP FA SERIES
Dc motar
|
PDF
|