Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WC166 Search Results

    SF Impression Pixel

    WC166 Price and Stock

    Thomas & Betts WC166-198MIN

    E-Z-Marker Card |Abb Thomas & Betts WC166-198MIN
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark WC166-198MIN Bulk 25
    • 1 $6.77
    • 10 $6.77
    • 100 $5.53
    • 1000 $4.43
    • 10000 $4.43
    Buy Now
    Onlinecomponents.com WC166-198MIN
    • 1 -
    • 10 -
    • 100 $3.9
    • 1000 $3.47
    • 10000 $3.28
    Buy Now
    Master Electronics WC166-198MIN
    • 1 -
    • 10 -
    • 100 $3.9
    • 1000 $3.47
    • 10000 $3.28
    Buy Now

    ABB Group WC166-198MIN

    Thomas & Betts
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Sager WC166-198MIN 25
    • 1 -
    • 10 -
    • 100 $4.54
    • 1000 $4.12
    • 10000 $4.12
    Buy Now

    WC166 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    andrew 4 port

    Abstract: WC281 4 port combiner Andrew ANTENNA 6,4 waveguide elliptical connector
    Text: ANDREW. SPECIFICATIONS FOR 4-PORT C O M B IN IN G NETWORK FOR SHX SUPER HIGH PERFORMANCE ANTENNA TYPE 205136 5 .9 2 5 -6 .4 2 5 GHz and and 1 0 .7 0 - 11.70 GHz Andrew's new compact 4 - port combining network is designed for use in SHX super high performance antenna systems and other circular waveguide applications. It


    OCR Scan
    PDF 153rd SP20-41 WC281 WC166 CQ462 252DET 190DET EWP52 EWP90 andrew 4 port 4 port combiner Andrew ANTENNA 6,4 waveguide elliptical connector

    WC281

    Abstract: PDR58 UG-595U WC109 UBR220 flange WR75 waveguide wr75 WC166
    Text: Circular-to-Rectangular Waveguide Transitions Dual Polarized without Mode Filter Dual Polarized with Mode Filter 1 Except 160515-177 is 18 in 457 mm Dual Polarized Circular-to-Rectangular Waveguide Transitions Frequency Band, GHz Rectangular Flange Mates with


    OCR Scan
    PDF WC281 WC166 WC109 CPR90G UG-596A/U, UG-595U PDR100 CPR229G PDR40 CPR137G PDR58 UBR220 flange WR75 waveguide wr75

    WC281

    Abstract: WC166 WC109 WC269 WR75 waveguide WC212 3642 CPR159G rectangular waveguide transition CPR-159G
    Text: A Termination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. Flange Type Load Type No CPR90G CPR112G CPR137G CPR159G CPR229G WR75 Cover/Gasket


    OCR Scan
    PDF CPR90G CPR112G CPR137G CPR159G CPR229G WR112 WC281. WC281 WC281ransitions WC166 WC109 WC269 WR75 waveguide WC212 3642 rectangular waveguide transition CPR-159G

    WC109

    Abstract: elliptical waveguide l46r WC166 wc 128 circular LDF7P-50A-1A 48940-C LDF4P-50A-1 L44R L5PNM
    Text: Microwave and Wireless System Planning System Planning Worksheet. Ask for Andrew Bulletin 8740. System Using C ircular and E llip tica l Waveguide Towers Because we manufacture all the system components, Andrew has a unique understanding of how to design a tower to properly support transmission lines and hold


    OCR Scan
    PDF H12PNF H12PDM 2396A-2 2396A-4 2396A-5 19256B 4312A WC109 elliptical waveguide l46r WC166 wc 128 circular LDF7P-50A-1A 48940-C LDF4P-50A-1 L44R L5PNM

    WR75 waveguide switch

    Abstract: UHX-34 SD-002A andrew pressurization monitor type 40004 heliax MTH-050 MT050 mr05 WC281 GLW1700
    Text: Dehydrator Selection Considerations • Total System Volume • System Pressure Rating • Availability of Maintenance • Availability o f Electric Power Total System Volume. System volume is determined by totaling the volume of each air dielectric transmission line


    OCR Scan
    PDF 2813A WR75 waveguide switch UHX-34 SD-002A andrew pressurization monitor type 40004 heliax MTH-050 MT050 mr05 WC281 GLW1700

    WC166

    Abstract: p-5 RELAY WC281 WC109 EWP52 coaxial cable group chart microwave waveguide EW240 EW20 elliptical waveguide
    Text: Transmission Lines Widest Selection of microwave transmission lines in the industry. Andrew offers sizes and types that are optimized for nearly every application. HELIAX Coaxial Cables and Elliptical Waveguides have been, for many years, the standard transmission


    OCR Scan
    PDF sR137, WR112 WC281, WC166 WC166 p-5 RELAY WC281 WC109 EWP52 coaxial cable group chart microwave waveguide EW240 EW20 elliptical waveguide

    WC281

    Abstract: CPR229G elliptical waveguide UG-595U WC166
    Text: M icrow ave Transm ission Lines Single Polarized Without Mode Filter Single Polarized With Mode Filter Circular-to-Rectangular Waveguide Transitions These transitions convert from circular to rectangular waveguides at one or both ends of the vertical run.


    OCR Scan
    PDF PDR100 PDR120 UG-596A/U, UG-595U CBR220, UBR220, PBR220 WC281 CPR229G elliptical waveguide UG-595U WC166

    Untitled

    Abstract: No abstract text available
    Text: System s Using Circular W aveguide Andrew offers terrestrial microwave antenna systems from 3.54 GHz to 19.7 GHz in a wide range of frequency band offerings to meet your system design requirements. The details below describe each component of the terrestrial microwave antenna


    OCR Scan
    PDF

    WC281

    Abstract: No abstract text available
    Text: M ic ro w a v e T ra n s m is s io n Lin es Circular W aveguide Low est Attenuation Circular waveguide offers substantially lower attenuation than elliptical or rectangular waveguide. This can result in the use of smaller antennas, reducing tower loading and saving antenna cost.


    OCR Scan
    PDF 8600A-1- 8600A-2- 8613A-150- 8613A-96- 8613A- WC281

    WC166

    Abstract: WC281 WC109 elliptical waveguide flexible waveguide 4 port combiner sliding
    Text: A Alignment Shorting Plate. A brass plate used during initial alignment. It is installed at the top of the run while the axial ratio compensator is adjusted. See table below. B Pulling Head. Attaches to top waveguide section flange. Waveguide sections can be assembled at


    OCR Scan
    PDF WC281 WC166 WC109 elliptical waveguide flexible waveguide 4 port combiner sliding

    ew43

    Abstract: HJ9-50 WC281 HJ12-50 UMX-459 heliax
    Text: Volumes ft3 liters 1000 ft 1000 m Line Type Caution: UMX-459,-465,-611; UHX-34,-35,-36,-37; HPX12-6511C; FP/FPX-34,-36; and P-186 antennas have lower pressure ratings than standard antennas as indicated in the chart below. HELIAX Pressurizable Coaxial Cable


    OCR Scan
    PDF UMX-459 UHX-34 HPX12-6511C; FP/FPX-34 P-186 SCL-950 HJ4-50 HJ5-50 LDF6-50 HJ7-50A ew43 HJ9-50 WC281 HJ12-50 heliax

    WC281

    Abstract: WC166 anchor flange waveguide circular sliding
    Text: M icrow ave Transmission Lines Circular Waveguide Support Systems The Andrew standard support system uses the rigid, spring/sliding, and sliding hangers. This system is available for all sizes except WC281. Typical system planning information is presented on pages 238 and


    OCR Scan
    PDF WC281. WC281 WC166. 9007A-109 9008A-109 9009A-109 WC109 WC166, WC166 anchor flange waveguide circular sliding

    WS108

    Abstract: WC166 WC281 Waveguide Gaskets CPR159G CPR-137 circular waveguide
    Text: Circular-to-Rectangular Waveguide Transitions A Term ination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. F la n g e Type Lo ad Type No.


    OCR Scan
    PDF CPR90G CPR112G CPR137G CPR159G CPR229G WR112 WR137 WC281 WC166 WC109 WS108 Waveguide Gaskets CPR-137 circular waveguide