Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WN2 4HR Search Results

    WN2 4HR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    wn2 4HR

    Abstract: 440N-C02068 440N-C02067 FERROCODE FERROCODE EN60204 440N-C02079 440n FERROCODE C02067 440nA automatic sliding doors sensor
    Text: Interlock Switches Non contact Switches Ferrocode Specifications continued Utilization Category (AC) 4A/250V AC/1000VA at COSϕ=1 Max Switched DC Current/Volt 2A/30V DC/60W Min Switched DC Current/Volt 10mA/10V Description Max Output Fuse 5A quick acting


    Original
    PDF A/250V AC/1000VA A/30V DC/60W 10mA/10V S21S22 28Vdc 120Vac wn2 4HR 440N-C02068 440N-C02067 FERROCODE FERROCODE EN60204 440N-C02079 440n FERROCODE C02067 440nA automatic sliding doors sensor

    guardmaster cu2

    Abstract: CU2 STOP MOTION DETECTION stop motion detector with pnp and npn sensor 6 way rotary selector switch dc sensor movimento 500mAT motion detector WITH RELAY switch wn2 4HR inductive sensor
    Text: ENGLISH The CU2 provides a stopped motion detection system and is used together with CU2 sensors supplied separately to detect movement of a machine via the flywheel, gear or shaft etc. Upon energisation the unit powers up (Red LED). When the sensor detects that the


    Original
    PDF

    FERROCODE

    Abstract: wn2 4HR Ferro sipha
    Text: The following example shows how to connect a Ferrocode Switch to a Sipha 2 Control Unit. The wire colour's although similar are connected differently between the Sipha and Ferrocode Products Ferrocode 24V DC N/C Circuit N/O Circuit Red & Blue Black & White


    Original
    PDF

    GuardMaster wn2 4hr

    Abstract: 02ATEX0183X EN50018 BS6007 guardmaster GuardMaster wn2 BS60079-14 EExdIIct6 GS213 500VA
    Text: FERROGARD MAGLOCK GS2, GS2H & GS2-1 GUARD SWITCHES Certification for GS2 & GS2-1. EExdIICT6 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000. Certification for GS2H. EExdIICT3 Certificate number 02ATEX0183X. Conforms to standards EN50014:1997 & EN50018:2000


    Original
    PDF 02ATEX0183X. EN50014 EN50018 BS60079-14 110VA 220VA 500VA GuardMaster wn2 4hr 02ATEX0183X BS6007 guardmaster GuardMaster wn2 EExdIIct6 GS213

    GuardMaster safety switch

    Abstract: wn2 4HR guardmaster 24VAC GuardMaster wn2 4hr minotaur msr7c EN60204-1 relay in ac application GuardMaster CONTROL UNIT
    Text: R MINOTAUR MSR7C 2 HAND CONTROL LOGIC UNIT For Capacitive Palm Button 2 hand control switch units with 2 x 1 N/O & 1N/C buttons. Power drain: Internal fuse: Safety Inputs: Indication: Relay outputs: Maximum switched current: Drop out time: Standards conformity:


    Original
    PDF 500mAT GuardMaster safety switch wn2 4HR guardmaster 24VAC GuardMaster wn2 4hr minotaur msr7c EN60204-1 relay in ac application GuardMaster CONTROL UNIT

    GuardMaster CONTROL UNIT EN 60204-1

    Abstract: minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT
    Text: MINOTAUR MSR9T INSTALLATION INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION 120.0 To gain access to switches & fuse flip off lid with a small screwdriver. 45.5 73 Access to replaceable fuse Voltage 230V Switch 110V Isolate power before opening. Drawing No. 23633


    Original
    PDF 120mm, GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T GuardMaster safety switch GuardMaster wn2 4hr MSR9T S2213 wn2 4HR en 60204-1 FUSE 500mA GuardMaster CONTROL UNIT

    Guardmaster EN1088

    Abstract: BS5304 EN1088 GS-ET-15 GuardMaster wn2 4hr GuardMaster safety switch GS-ET15 BS53 wn2 4HR JET 2A 250V
    Text: INSTALLATION INSTRUCTIONS MONTAGEANLEITUNG / NOTICE D'INSTALLATION 4 1mm min 2.5mm max 2 x M4 2 6 2 x M4 5 1 3 2.5mm y Entr End mm & nt Fro in. 150 m B1 B2 0mm . 20 mm n i try m 150 t En min. Fron Entry End 2 x M4 2 ELF 1 Conduit M16 PG9 entry Part 33001 33002


    Original
    PDF

    l455

    Abstract: minotaur msr8t GuardMaster wn2 4hr S14 contactor DC-13 wn2 4HR DIN VDE 0113 switch GuardMaster safety switch msr8t GuardMaster minotaur msr6r/t
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformiätserklärung. Voir la declaration de conformite ä-jointe pour details MINOTAUR MSR8T SINGLE CHANNEL INPUT MONITORING SAFETY RELAY & EXTENSION UNIT. RELAIS-SICHERHEITSBAUSTEIN FÜR SICHERHEITSSCHALTER UND NOT-AUS-BEFEHLSGERÄTE 1-KANALIGER EINGANG UND ERWEITERUNGSEINHEIT.


    Original
    PDF 110VAC FROMS13 230VAC l455 minotaur msr8t GuardMaster wn2 4hr S14 contactor DC-13 wn2 4HR DIN VDE 0113 switch GuardMaster safety switch msr8t GuardMaster minotaur msr6r/t

    GuardMaster trojan 5

    Abstract: GuardMaster trojan 5 6 guardmaster 947-5-1 GuardMaster guardmaster IEC 947-5-1 GuardMaster wn2 4hr IEC 60947-5-1 ip 67 Guardmaster EN1088 guardmaster IEC 60947-5-1 trojan 5
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. SPECIALISTS IN MACHINERY SAFETY UL C UL R 940060 R Listed UNIVERSAL TONGUE OPERATED SAFETY INTERLOCK SWITCH.


    Original
    PDF 175mm 75mm2. UL508 GuardMaster trojan 5 GuardMaster trojan 5 6 guardmaster 947-5-1 GuardMaster guardmaster IEC 947-5-1 GuardMaster wn2 4hr IEC 60947-5-1 ip 67 Guardmaster EN1088 guardmaster IEC 60947-5-1 trojan 5

    minotaur MSR6R/T Universal Safety Relay

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique
    Text: See enclosed Declaration of Conformity for details. Siehe Anlage: Konformitätserklärung. Voir la declaration de conformite ci-jointe pour details. MINOTAUR MSR6R/T Universal Monitoring Safety Relay For Interlock Switches And Emergency Stop Devices. Relais-Sicherheitsbaustein für Sicherheitsschalter und NOT-AUS-Befehlsgeräte.


    Original
    PDF S13-S14 S23-S24. minotaur MSR6R/T Universal Safety Relay GuardMaster CONTROL UNIT EN 60204-1 GuardMaster GuardMaster CONTROL UNIT minotaur msr6r/t GuardMaster wn2 4hr MSR6R/T wn2 4HR GuardMaster safety switch logique

    MSR9T

    Abstract: A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T
    Text: ACCESSOIRES ZUBEHÖR e ACCESSORIES Security screwdriver Replacement Resistorx security key GD2 accessoy kit Replacement actuators are available by arrangement. Note: Access to spare actuators should be restricted to authorised personnel to prevent bypassing of the safety function


    Original
    PDF UL508 MSR9T A600 GS-ET-15 IEC68 guardmaster IEC 60947-5-1 GuardMaster gd2 GuardMaster CONTROL UNIT EN 60204-1 minotaur MSR9T

    MSR15D

    Abstract: bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA
    Text: Beschreibung Der MINOTAUR MSR15D ist ein Sicherheitsbaustein, der die korrekte Funktion von Sicherheitsstromkreisen überwacht. Er ist mit unverzögerten und verzögerten Ausgängen versehen. Mit einer 2-kanaligen Eingangskonfiguration überwacht das Gerät


    Original
    PDF MSR15D D13/D14ortie bouton poussoir ci GuardMaster GuardMaster safety switch GuardMaster CONTROL UNIT EN 60204-1 EN1050 anzeige GuardMaster CONTROL UNIT tuv sp 1000VA

    GuardMaster

    Abstract: MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique
    Text: a Beschreibung (a) Description The Minotaur MSR7R is a safety relay specifically designed for monitoring of two hand control switches. Using dual channel inputs, the unit checks the operation of two independent 1 N/O and 1 N/C actuators and then gives the approprite


    Original
    PDF 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster MSR6R/T minotaur msr6r/t MSR7R 1000v contactor GuardMaster CONTROL UNIT wn2 4HR minotaur GuardMaster wn2 4hr circuit logique

    guardmaster cu2

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204
    Text: a CU3 Description The CU3 has been designed to detect motion of single phase or three phase motors, by measuring the back electro magnetic field (e.m.f) of the motor on two terminals of one stator winding. When the supply is turned down to zero or disconnected and the back e.m.f. is less than 0.5 volts AC (motor


    Original
    PDF 98/37/EC) 73/23/EEC guardmaster cu2 GuardMaster CONTROL UNIT EN 60204-1 GuardMaster gd2 GuardMaster 6 volt dc to 110v ac inverter circuit diagram GuardMaster CONTROL UNIT cu2 stop motion detection FUSE 500mA GuardMaster wn2 4hr diode led rouge 5mm GuardMaster CONTROL UNIT cu2 EN 60204

    GuardMaster CONTROL UNIT EN 60204-1

    Abstract: MSR16 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1
    Text: a MONITORING MINOTAUR MSR16R/T (b) Description The MSR16R/T will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after


    Original
    PDF MSR16R/T MSR16R/T S13-S14 S23-S24. MSR16 98/37/EC) 73/23/EEC GuardMaster CONTROL UNIT EN 60204-1 GuardMaster safety switch GuardMaster safety switch msr16 EN1050 GuardMaster CONTROL UNIT diode led rouge 3 mm GuardMaster 1800W EN60204-1

    MSR11R

    Abstract: GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020
    Text: a MINOTAUR MSR11R (b) Description This unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be resumed after both inputs are open and then closed synchronously


    Original
    PDF MSR11R MSR11R 98/37/EC) 73/23/EEC 89/336/EEC GuardMaster CONTROL UNIT EN 60204-1 minotaur alimentation pc GuardMaster CONTROL UNIT Deutsch Relay 4a GuardMaster safety switch MSR11 MSR12T EN6020

    GuardMaster gd2

    Abstract: guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600
    Text: a CADET 3 Description The Cadet 3 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open. (b) ? Installation Instructions


    Original
    PDF 98/37/EC) 73/23/EEC GuardMaster gd2 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH GUARDMASTER CADET 3 gd2 guardmaster GuardMaster CONTROL UNIT EN 60204-1 GuardMaster CONTROL UNIT GuardMaster safety switch 9053B A600

    MSR12T

    Abstract: MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am
    Text: MSR12T MONITORING SAFETY RELAY ÜBERWACHUNGS-/SCHUTZRELAIS RELAIS DE SECURITE POUR CONTROLE b Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only


    Original
    PDF MSR12T S13-S14 S23-S24. MSR12T 98/37/EC) 73/23/EEC 89/336/EEC MSR12 GuardMaster CONTROL UNIT GuardMaster CONTROL UNIT EN 60204-1 GuardMaster 35MM EN292 EN954-1 GuardMaster wn2 4hr fusible Am

    GuardMaster ferrogard 21DC

    Abstract: BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster
    Text: FERROGARD GD2 b Description The Ferrogard GD2 range of magnetically actuated, non-contact safety interlock switches are used to stop machine power when a guard is opened. When the stop signal is applied and the guard is opened, the action of the actuator being removed from the switch


    Original
    PDF 98/37/EC 73/23/EEC GuardMaster ferrogard 21DC BS3146 GuardMaster CONTROL UNIT EN 60204-1 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC Guardmaster EN1088 Reed Magnete interrupteur commutateur GuardMaster

    GuardMaster ferrogard 21DC

    Abstract: Ferrogard 21DC FERROCODE EN60204 Ferrogard 21AC GuardMaster FRS 6 frs3 relay ferrogard Guardmaster EN1088 frs 21 dc guardmaster
    Text: a Description (a) Description SPECIALISTS IN MACHINERY SAFETY Ferrogard FRS 1, 2, 3, 4, 5, 6, 9, 10, 20DC, 21AC, 21DC, GS1 & GS2 MAGNETICALLY OPERATED SAFETY SWITCH MAGNET-SICHERHEITSSCHALTER INTERRUPTEUR DE SECURITE MAGNETIQUES SANS CONTACT See enclosed Declaration of Conformity for details.


    Original
    PDF

    guardmaster atlas 4

    Abstract: GuardMaster atlas 5 gd2 guardmaster atlas 3 safety switch guardmaster atlas safety switch cerberus cu2 ATLAS 5 gd2 guardmaster safety switch bouton poussoir ci guardmaster atlas 4 safety switch GuardMaster guardmaster cu2
    Text: ATLAS 5-GD2 a HEAVY DUTY SOLENOID LOCKING SAFETY SWITCH ÄUßERST ROBUSTE SICHERHEITSZUHALTUNG OPTIONAL / OPTION (b) Description. The Atlas 5 (with optional trapped key) is a positive mode, tongue operation, machine guard locking interlock switch. It locks the guard closed until the


    Original
    PDF

    GuardMaster trojan 5

    Abstract: GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 GuardMaster Catalogue SAFETY SWITCH guardmaster trojan 5 AC15 trojan 5 bouton poussoir GuardMaster CONTROL UNIT EN 60204-1 GuardMaster wn2 4hr
    Text: TONGUE OPERATED GUARD INTERLOCK SWITCH - INC. STANDARD & EX VERSIONS TROJAN 5 a Description The Trojan 5 is a positive mode, tongue operated interlock switch. It interlocks the guard to the machine control system and ensures machine power is isolated and remains isolated whilst the guard is open.


    Original
    PDF