Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    X-RAY TUBE Search Results

    X-RAY TUBE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CR6KM-12A#B00 Renesas Electronics Corporation Thyristors, TO-220FN, /Tube Visit Renesas Electronics Corporation
    CR3AS-8ME#B00 Renesas Electronics Corporation Thyristors, MP-3A, /Tube Visit Renesas Electronics Corporation
    CR6LM-12B#B00 Renesas Electronics Corporation Thyristors, TO-220FL, /Tube Visit Renesas Electronics Corporation
    CR3PM-12G-A8#B00 Renesas Electronics Corporation Thyristors, TO-220F, /Tube Visit Renesas Electronics Corporation
    CR8KM-12A#B00 Renesas Electronics Corporation Thyristors, TO-220FN, /Tube Visit Renesas Electronics Corporation

    X-RAY TUBE Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    L9191

    Abstract: L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919
    Text: X-RAY I.I. CAMERA UNIT SERIES X-RAY C7336-50/-51, C7876/-10, C7716/-10 IMAGING X-ray Image Intensifier X-ray I.I. + CCD Camera High-quality X-ray images. Both low energy and high magnification are available. ▲Flower (C7876, X-ray tube voltage: 10 kV) ▲BGA


    Original
    C7336-50/-51, C7876/-10, C7716/-10 C7876, C7716, C7876/-10) C7336-50/-51 C7716/-10) LC7336-50/-51, L9191 L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919 PDF

    VICTOREEN model 500

    Abstract: intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P
    Text: X-RAY IMAGE INTENSIFIERS High DQE • Excellent Image Quality • High Contrast An X-ray image intensifier is a large image tube that converts a low intensity X-ray image into a visible image. It is used for medical X-ray TV systems, X-ray nondestructive inspection systems,


    Original
    S-164 1004E03 VICTOREEN model 500 intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P PDF

    Untitled

    Abstract: No abstract text available
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 SE-171-41 TAPP1056E02 PDF

    Untitled

    Abstract: No abstract text available
    Text: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-05/-52 •BGA ●Digital type C7336-05 Clear, Sharp Image X-ray tube voltage: 80 kV ●Analog type OVERVIEW The C7336 series consist of a high resolution, high contrast 4inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel


    Original
    C7336-05/-52 C7336-05) C7336 IEEE1394b. SE-164 TXPR1017E04 B1201 PDF

    x-ray tube

    Abstract: AC Photonics H8953 scintillator x-ray tube datasheet H8480 H8481 H8481-15 rear CCD camera VA-033B
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 SE-171-41 TAPP1056E02 x-ray tube AC Photonics H8953 scintillator x-ray tube datasheet H8481 H8481-15 rear CCD camera VA-033B PDF

    Untitled

    Abstract: No abstract text available
    Text:  X-RAY X-CUBE COMPACT X-RAY CCD CAMERAS IMAGING H8480/H8481/H8953 Series SAMPLE X-RAY IMAGES Sample: Cellular phone substrate X-ray tube voltage: 90 kV, Geometrical magnification rate: x1.15 H8480 Effective view: 25 mm Min. Resolution : 10 Lp/mm Typ. H8481


    Original
    H8480/H8481/H8953 H8480 H8481 H8953 H8480 25Tewin SE-164 TXPR1020E01 PDF

    Untitled

    Abstract: No abstract text available
    Text: X-RAY I.I. CAMERA UNIT C7716, C7716-10 NEW 3”/1.8” Dual Mode X-ray Image Intensifier X-Ray I. I. Efficiently Coupled to CCD Camera Captures sharp, clear X-ray images even from light element materials ! The C7716 series X-ray image intensifier (I. I.) camera


    Original
    C7716, C7716-10 C7716 SE-171-41 1043E04 PDF

    x-ray tube

    Abstract: TLSOB0102EA IEC61326 L10321 xray microfocus x-ray X-RAY INSPECTION x-ray tube datasheet C7716 C7716-10
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    L10321 TLSOF0185 SE-171-41 TLSO1058E03 x-ray tube TLSOB0102EA IEC61326 L10321 xray microfocus x-ray X-RAY INSPECTION x-ray tube datasheet C7716 C7716-10 PDF

    x-ray tube

    Abstract: intensifier microfocus x-ray C7716 C7716-10 x-ray view box CCD MARKING Image intensifier tube
    Text: X-RAY I.I. CAMERA UNIT C7716, C7716-10 NEW 3-inch/1.8-inch Dual Mode X-ray Image Intensifier X-Ray I. I. Efficiently Coupled to CCD Camera Captures sharp, clear X-ray images even from light element materials ! The C7716 series X-ray image intensifier (I. I.) camera


    Original
    C7716, C7716-10 C7716 SE-171-41 1043E05 x-ray tube intensifier microfocus x-ray C7716-10 x-ray view box CCD MARKING Image intensifier tube PDF

    Untitled

    Abstract: No abstract text available
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    L9631 RS-232C) SE-171-41 TXPR1014E01 PDF

    Untitled

    Abstract: No abstract text available
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    L10321 TLSOF0185 SE-171-41 TXPR1013E01 PDF

    x-ray

    Abstract: 3 ccd progressive scan C7336-03 AC Photonics interline sharp CCD Camera C7716 "frame grabber"
    Text: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-03/-04 OVERVIEW The C7336-03/04 consist of a high resolution, high contrast 4-inch X-ray image intensifier X-ray I.I. and a 1.45 megapixel digital CCD camera. The X-ray I.I. used has a fixed field-of-view of 100


    Original
    C7336-03/-04 C7336-03/04 SE-171-41 1053E02 x-ray 3 ccd progressive scan C7336-03 AC Photonics interline sharp CCD Camera C7716 "frame grabber" PDF

    Untitled

    Abstract: No abstract text available
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ● Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    L9181-02 RS-232C) SE-171-41 TXPR1015E01 PDF

    X-RAY thickness

    Abstract: x-ray tube L9631 X-RAY INSPECTION x-ray tube datasheet t6.3a 250v microfocus x-ray x-ray x-ray tube operation C7716-10
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    L9631 RS-232C) SE-171-41 TLSO1053E05 X-RAY thickness x-ray tube L9631 X-RAY INSPECTION x-ray tube datasheet t6.3a 250v microfocus x-ray x-ray x-ray tube operation C7716-10 PDF

    car front camera

    Abstract: x-ray x-ray tube 20kv solid relay x-ray tube datasheet C7077 C7716 C7716-10 C7876-10 X-RAY thickness
    Text: X-RAY I.I. CAMERA UNIT C7876, C7876-10 NEW 4” X-ray Image Intensifier with Beryllium Window Efficiently Coupled to CCD Camera Captures low-energy X-ray images in real time! The C7876 series X-ray image intensifier X-ray I. I. camera units are ideal for non-destructive inspection of light-element


    Original
    C7876, C7876-10 C7876 SE-171-41 1047E01 car front camera x-ray x-ray tube 20kv solid relay x-ray tube datasheet C7077 C7716 C7716-10 C7876-10 X-RAY thickness PDF

    L9421-02

    Abstract: L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    L9421-02 RS-232C) SE-171-41 TLSO1055E03 L9421-02 L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953 PDF

    Untitled

    Abstract: No abstract text available
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    L9421-02 RS-232C) SE-171-41 TXPR1011E01 PDF

    HAMAMATSU L9181

    Abstract: L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ●Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    L9181-02 RS-232C) SE-171-41 TLSO1061E01 HAMAMATSU L9181 L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716 PDF

    Untitled

    Abstract: No abstract text available
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10101 Short FOD: 6.8 mm TLSOF0185 FEATURES ●Short FOD Focus to Object Distance : 6.8 mm X-ray image with Higher Magnification ratio ●High Power: Maximum Output 20 W ●Focal Spot Size: 5 µm (at 4 W) The focal spot of 5 µm of the sealed type X-ray tube enables


    Original
    L10101 TLSOF0185 SE-171-41 TXPR1012E01 PDF

    Untitled

    Abstract: No abstract text available
    Text: PHOTODIODE Si photodiode S8559 Detector for X-ray monitor Features Applications l Si photodiode coupled to low cost CsI scintillator l Ideal for detection of X-ray energy below 100 keV l X-ray detection l X-ray monitors • Absolute maximum ratings Ta=25 °C


    Original
    S8559 SE-171 KSPD1051E01 PDF

    scintillator

    Abstract: S8559 x-ray tube SE-171
    Text: PHOTODIODE Si photodiode S8559 Detector for X-ray monitor Features Applications l Si photodiode coupled to low cost CsI scintillator l Ideal for detection of X-ray energy below 100 keV l X-ray detection l X-ray monitors • Absolute maximum ratings Ta=25 °C


    Original
    S8559 SE-171 KSPD1051E02 scintillator S8559 x-ray tube PDF

    Untitled

    Abstract: No abstract text available
    Text: PHOTODIODE Si photodiode S8559 Detector for X-ray monitor Features Applications l Si photodiode coupled to low cost CsI scintillator l Ideal for detection of X-ray energy below 100 keV l X-ray detection l X-ray monitors • Absolute maximum ratings Ta=25 °C


    Original
    S8559 SE-171 KSPD1051E02 PDF

    scintillator

    Abstract: x-ray tube 026 S8559 SE-171 telephone x-ray tube dark current
    Text: PHOTODIODE Si photodiode S8559 Detector for X-ray monitor Features Applications l Si photodiode coupled to low cost CsI scintillator l Ideal for detection of X-ray energy below 100 keV l X-ray detection l X-ray monitors • Absolute maximum ratings Ta=25 °C


    Original
    S8559 SE-171 KSPD1051E01 scintillator x-ray tube 026 S8559 telephone x-ray tube dark current PDF

    Untitled

    Abstract: No abstract text available
    Text: Fairchild Imaging Sensors Application Note: X-Ray Imaging with CC D Image Sensors by R.H. Dyck X-ray imaging is conventionally done with either photographic film, X-ray phosphor screens viewed directly, or X-ray image converter tubes coupled to a vidicon-type of television camera.


    OCR Scan
    PDF