    Honeywell Sensing and Control AWM2300VH

    SENSOR UNAMP +1000 SCCM
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey AWM2300VH Bulk 50
    • 1 -
    • 10 -
    • 100 $188.424
    • 1000 $188.424
    • 10000 $188.424
    Buy Now
    Mouser Electronics AWM2300VH
    • 1 -
    • 10 -
    • 100 $355.69
    • 1000 $355.69
    • 10000 $355.69
    Get Quote
    Newark AWM2300VH Bulk 50
    • 1 $295.2
    • 10 $295.2
    • 100 $277.83
    • 1000 $225.74
    • 10000 $208.38
    Buy Now
    Onlinecomponents.com AWM2300VH
    • 1 -
    • 10 -
    • 100 $198.42
    • 1000 $198.42
    • 10000 $198.42
    Buy Now
    Master Electronics AWM2300VH
    • 1 -
    • 10 -
    • 100 $198.42
    • 1000 $198.42
    • 10000 $198.42
    Buy Now

    Honeywell Sensing and Control / MICRO SWITCH AWM2300VH

    Flow Sensors AIRFLOW/NEW PRESSURE
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Sager AWM2300VH 5
    • 1 -
    • 10 $253.65
    • 100 $253.65
    • 1000 $253.65
    • 10000 $253.65
    Buy Now

    AWM2300VH Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    AWM2300VH Honeywell Airflow Sensor, Signal Conditioning: Unamplified (mV); Flow/Pressure Range: ±1000 sccm (1.0 SLPM); Port Style: Straight Original PDF
    AWM2300VH Honeywell Airflow Sensor, Signal Conditioning: Unamplified (mV); Flow/Pressure Range: ±1000 sccm (1.0 SLPM); Port Style: Straight Scan PDF

    AWM2300VH Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    hydrogen gas sensor

    Abstract: nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility – Note #4 The microbridge mass airflow sensor incorporates a limited number of wetted materials in the construction of the device. The wetted materials in the sensor are fairly non-reactive and are compatible


    Original
    PDF AWM2100VH, AWM2300VH, AWM42150VH. hydrogen gas sensor nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor

    "Flow Sensor"

    Abstract: helium sensor AWM2100V AWM2200V AWM2000 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH
    Text: AWM2000 Series Mass flow sensor for gases FEATURES • Ranges 0.±30 to 0.±1000 sccm1 or 0.±4 "H2O 0.±10 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid


    Original
    PDF AWM2000 gas11 AWM2150V AWM2100V AWM2100VH AWM2300V AWM2300VH AWM2200V "Flow Sensor" helium sensor AWM2100V AWM2200V 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH

    helium sensor

    Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility - Note # 4 The microbridge mass airflow sensor in­ corporates a limited number of wetted materials in the construction of the de­ vice. The wetted materials in the sensor


    OCR Scan
    PDF AWM21OOVH, AWM2300VH, AWM42150VH. 1-800-737-3360Canada

    Untitled

    Abstract: No abstract text available
    Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper­ ature sensing resistor located on either side of the heater. The


    OCR Scan
    PDF