Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CP72BL Search Results

    SF Impression Pixel

    CP72BL Price and Stock

    Panduit Corp CP72BL

    Wire Ducting & Raceways Patch Panel 72 Port Modular All Metal
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Mouser Electronics CP72BL
    • 1 $152.25
    • 10 $147.91
    • 100 $139.21
    • 1000 $139.21
    • 10000 $139.21
    Get Quote
    Sager CP72BL
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    CP72BL Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    mb 11801

    Abstract: TX5500 ISO 11801 acr CPA72BL PSFC5504LG-ED PSFL5504DG-ED D11801 acr 100
    Text: TX5e Shielded Patch Cord SPECIFICATION SHEET specifications Patch cords shall be constructed of shielded 26 AWG stranded copper cable and shielded high performance modular plugs at each end. Patch cords shall be used in all work area outlets and patch panels. Patch cords shall be offered in gray


    Original
    PDF T568A T568B TX5500 NCSP16 WW-NCSP16 mb 11801 ISO 11801 acr CPA72BL PSFC5504LG-ED PSFL5504DG-ED D11801 acr 100

    Untitled

    Abstract: No abstract text available
    Text: TX6A 10Gig™ Keyed Shielded Patch Cords S P E C I F I C AT I O N S H E E T specifications Category 6A/Class EA, S/FTP keyed patch cords shall be constructed of 26 AWG shielded twisted pair stranded copper cable with keyed modular plug on one end and a non-keyed modular plug on the other end. Keyed modular


    Original
    PDF 10Gigâ COSP242 COSP242--WW-ENG WW-COSP161

    PSP6004BU-UG

    Abstract: CJS6X88TGY 10GIGTM M/10/100/1000/10GBASE-T
    Text: TX6 10GIG ™ Shielded Jack Module SPECIFICATION SHEET specifications Augmented Category 6 eight-position jack module shall terminate shielded twisted 4-pair 22-26 AWG 100 ohm cable and shall not require the use of a punchdown tool. Jack module shall use forward motion termination to optimize


    Original
    PDF 10GIG T568A T568B 10GBASE-T 10GIGTM CJS6X88TGY COSP58 PSP6004BU-UG M/10/100/1000/10GBASE-T

    CP72BL

    Abstract: RJ48X CPP24WBL
    Text: specifications Eight position Category 3 modular jack shall terminate four conductors using positions 1, 2, 4 and 5 of an RJ48X interface. The jack shall have shorting bars to avoid signal interruption when plug is disengaged from jack. The jack shall terminate 24 awg cable without requiring the use


    Original
    PDF RJ48X UL94-V0 SA117N280-OP CP72BL CPP24WBL

    pgke

    Abstract: No abstract text available
    Text: specifications TM Eight position module shall be used in all work areas and shall exceed the requirements of the TIA/EIA568-B Category 5e standard. The module termination to 4 pair 24 and 22 AWG 100 ohm solid shielded twisted pair cable shall be accomplished by use of a


    Original
    PDF TIA/EIA568-B TIA/EIA-568-B SA-NC10CB01A WW-CPSP03 pgke

    PUFL6X04WH-KD

    Abstract: PUFR6X04BU-UG ISO 11801 IEC 60603-7 PUFP6X04BU-UG PSL7004DG-ED psl70 PSANEXT LSZH 10GIGTM
    Text: TX6A 10Gig ™ Shielded Patch Cords S P E C I F I C AT I O N S H E E T specifications Category 6A/Class EA, S/FTP patch cords shall be constructed of 26 AWG shielded twisted pair stranded copper cable with an enhanced performance shielded modular plug at each end. Patch


    Original
    PDF 10Gig T568A T568B 10GigTM 10GBASE-T COSP59 WW-COSP59 PUFL6X04WH-KD PUFR6X04BU-UG ISO 11801 IEC 60603-7 PUFP6X04BU-UG PSL7004DG-ED psl70 PSANEXT LSZH

    CJSK6X88TG

    Abstract: 10GIGTM TX6atm
    Text: Mini-Com TX6A 10Gig™ Shielded Jack Modules S P E C I F I C AT I O N S H E E T specifications Category 6A/Class EA, 8-position, shielded jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool. Shielded


    Original
    PDF 10GigTM T568A T568B 10GBASE-T COSP230 COSP230--WW-ENG WW-COSP58 CJSK6X88TG TX6atm

    Untitled

    Abstract: No abstract text available
    Text: Mini-Com TX6 PLUS Shielded Jack Modules specifications Category 6/Class E, 8-position, shielded jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool. Shielded jack modules shall use a forward motion


    Original
    PDF T568A T568B ANSI/TIA-568-C COSP315--WW-ENG WW-COSP35

    Untitled

    Abstract: No abstract text available
    Text: Mini-Com TX6 PLUS Shielded Jack Modules S P E C I F I C AT I O N S H E E T specifications Category 6/Class E, 8-position, shielded jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool. Shielded jack modules shall


    Original
    PDF T568A T568B COSP234 COSP234--WW-ENG

    CPA72BLY

    Abstract: No abstract text available
    Text: TX5500 Shielded Copper Cable – F/UTP S P E C I F I C AT I O N S H E E T specifications Category 5e cable shall exceed ANSI/TIA-568-C.2 and IEC 61156-5 Category 5e component standards. The conductors shall be 24 AWG construction and the twisted pairs shall be wrapped in an overall metallic foil within a


    Original
    PDF TX5500â ANSI/TIA-568-C TX5500 PFL5504DG PFC5504LG-KD CJS5E88TGY COSP298--WW-ENG CPA72BLY

    Panduit - CMDSAQLCZBL

    Abstract: manual legrand 037 71 schematic diagram RCA to HDMI project 24 fiber mtp array polarity Thomas & Betts colored - keyed terminals
    Text: PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems SECTION INDEX Click on any section below to go to that portion for a detailed Table of Contents Table of Contents Click on the logo above to go to www.panduit.com up to date product information find a local distributor


    Original
    PDF SA-ELCB10 Panduit - CMDSAQLCZBL manual legrand 037 71 schematic diagram RCA to HDMI project 24 fiber mtp array polarity Thomas & Betts colored - keyed terminals

    CP24BL

    Abstract: CP48BL CP16BL patch panel 24 ports
    Text: M INI -C OM Flat All Metal Shielded Modular Patch Panels ® SPECIFICATION SHEET specifications Flat all metal shielded modular patch panels shall be made completely of metal and mount to standard cabinets, EIA 19" or 23" racks. Flat all metal shielded modular patch


    Original
    PDF 72-port COSP56 WW-COSP56 CP24BL CP48BL CP16BL patch panel 24 ports

    10GIGTM

    Abstract: No abstract text available
    Text: TX6 10GIG ™ Shielded Patch Cords SPECIFICATION SHEET specifications Category 6A shielded patch cords shall be constructed of shielded 26 AWG stranded copper cable and an enhanced performance shielded modular plug at each end. Patch cord cable shall be offered in colored S/STP cable with a black


    Original
    PDF 10GIG T568A T568B 10GIGTM 10GBASE-T COSP59 WW-COSP59

    stpc2mbbl

    Abstract: No abstract text available
    Text: M INI -C OM ® TX5e Shielded Jack Module SPECIFICATION SHEET specifications Eight-position jack module shall terminate 4 pair 22-26 AWG 100 ohm shielded twisted pair cable and shall not require the use of a punchdown tool. Jack module shall use forward motion termination to optimize


    Original
    PDF T568A T568B TX5500 CJS5E88TG COSP36 WW-COSP36 stpc2mbbl

    CP24WSBLY

    Abstract: CP48WSBLY CP48BLY CP24BLY D 437 SRBS19BL-XY
    Text: M INI -C OM Flat All Metal Shielded Modular Patch Panels ® SPECIFICATION SHEET specifications Flat all metal shielded modular patch panels shall be made completely of metal and mount to standard cabinets and EIA 19" racks. Flat all metal shielded modular patch


    Original
    PDF 72-port COSP56 WW-COSP56 CP24WSBLY CP48WSBLY CP48BLY CP24BLY D 437 SRBS19BL-XY

    Untitled

    Abstract: No abstract text available
    Text: TX5500 Shielded Cable – S/FTP SPECIFICATION SHEET specifications The S/FTP shielded cable shall be constructed of 4-pair insulated 24 AWG conductors. The twisted pairs shall be wrapped in an overall metallic foil with an overall braid within a LSZH


    Original
    PDF TX5500 PSFL5504DG-ED PSFL5504LG-ED TIA/EIA-568-B NCSP19 WW-NCSP19

    ISO 11801

    Abstract: CJS688TGY CJSK688TG PSR6004 ISO STANDARDS SHEET METAL IEC 60603-7 RJ45 modular jack 6 log TX6 tia 568 c
    Text: Mini-Com TX6 PLUS Shielded Jack Modules SPECIFICATION SHEET specifications Category 6/Class E, 8-position, shielded jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool.


    Original
    PDF T568A T568B CJS688TGY* CJSK688TG* COSP35 WW-COSP35 ISO 11801 CJS688TGY CJSK688TG PSR6004 ISO STANDARDS SHEET METAL IEC 60603-7 RJ45 modular jack 6 log TX6 tia 568 c

    PSR6004BU-UGY

    Abstract: STP6X2MIG PSP6004BU-UG CP24BL PSP6004 10GIGTM STP6X10MIG log TX6 PSANEXT
    Text: TX6 10GIG ™ Shielded Cable – U/FTP SPECIFICATION SHEET specifications Augmented Category 6 Shielded Copper Cable shall be constructed of 4-pair twisted insulated 23 AWG conductors. Each individual pair shall have a metallic foil shield and all four pairs shall


    Original
    PDF 10GIG 10GIGTM 10GBASE-T PSP6004BU-UG PSR6004BU-UGY COSP55 WW-COSP55 PSR6004BU-UGY STP6X2MIG CP24BL PSP6004 STP6X10MIG log TX6 PSANEXT

    CP24WSBLY

    Abstract: 48-port CP24BLY
    Text: Mini-Com All Metal Shielded Modular Patch Panels S P E C I F I C AT I O N S H E E T specifications All metal modular patch panels shall be made of stainless steel and mount to standard racks and cabinets. All metal patch panels shall accept all Mini-Com® Shielded Jack Modules for shielded


    Original
    PDF COSP56 WW-COSP56 CP24WSBLY 48-port CP24BLY

    10GIGTM

    Abstract: No abstract text available
    Text: Mini-Com TX6A 10Gig™ Shielded Jack Modules S P E C I F I C AT I O N S H E E T specifications Category 6A/Class EA, 8-position, shielded jack module shall terminate 4-pair, 22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use of a punchdown tool. Shielded


    Original
    PDF 10GigTM T568A T568B 10GBASE-T COSP58 WW-COSP58