Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    DIL1M Search Results

    DIL1M Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    DIL3M80

    Abstract: DIL0M DILM225 DIL00M DIL3AM85 DIL1M dil2m moeller DIL 10 M DIL4AM145 DIL4M115
    Text: Product group data DILEEM General Standards and specifications IEC/EN 60947, VDE 0660, CSA, UL Operations Lifespan, mechanical x 106 10 Ops./h 9000 Maximum operating frequency Mechanical See pages 5/6 Operating frequency Damp heat, constant, to IEC 60 068-2-3, Damp heat,


    Original
    DC-13 DC-13, DIL3M80 DIL0M DILM225 DIL00M DIL3AM85 DIL1M dil2m moeller DIL 10 M DIL4AM145 DIL4M115 PDF

    DIL00AM

    Abstract: DIL4M115 DIL3AM85 dil00m DIL4AM145 DIL00BM-10 DIL00M-10 DIL00M-G dil3m80 DIL2AM-G
    Text: I06_012-013_b_gb.fm Seite 12 Dienstag, 18. März 2003 1:27 13 6/12 Moeller HPL0211-2003/2004 3-pole Screw terminals DIL contactors 3-pole, 4-pole basic units Rated operational current AC-3 380 V 400 V Ie A Max. rating for three-phase motors, 50 – 60 Hz AC-3


    Original
    HPL0211-2003/2004 DIL3M80 24VDC) DIL3AM85 DIL4M115 230V50HZ) DIL4AM145 DIL00AM dil00m DIL00BM-10 DIL00M-10 DIL00M-G DIL2AM-G PDF

    DIL1M

    Abstract: DIL1AM DIL2AM DIL0M DIL3AM85 DILM250 DILM400 DIL3M80 DIL4AM145 DIL4M115
    Text: Product group data DILEM4 General Standards and specifications IEC/EN 60947, VDE 0660, CSA, UL Maximum operating frequency Mechanical Ops./h 9000 Damp heat, constant, to IEC 60 068-2-3, Damp heat, cyclical, to IEC 60 068-2-30 Climatic proofing Ambient temperature


    Original
    DC-13 DC-13, DIL1M DIL1AM DIL2AM DIL0M DIL3AM85 DILM250 DILM400 DIL3M80 DIL4AM145 DIL4M115 PDF

    MOELLER Z00 10

    Abstract: DF5-322-1K5 PKZM0-XDM12 DF5-322-2K2 DIL00AM DF5-322-075 DF5-340-7K5 DS4-340-15K-MX dil2m DIL00M
    Text: www.moeller.co.uk Industrial Switchgear Short Form Catalogue 2005/2006 Think future. Switch to green. Moeller – Market leaders in industrial switchgear Moeller has been at the forefront of switching, protecting and controlling motors for over 100 years. Setting standards with DIL contactors and PKZ


    Original
    D-53115 SK0211-1149GB MOELLER Z00 10 DF5-322-1K5 PKZM0-XDM12 DF5-322-2K2 DIL00AM DF5-322-075 DF5-340-7K5 DS4-340-15K-MX dil2m DIL00M PDF

    DIL1M

    Abstract: DIL0M DIL1AM DIL2AM DILM250 DILM225 DILM400 DILM820 DIL3M80 DIL4M115
    Text: Product group data DILEM General Standards and specifications IEC/EN 60947, VDE 0660, CSA, UL Operations Lifespan, mechanical x 106 10 Ops./h 9000 Maximum operating frequency Mechanical Operating frequency See Pages 5/6 Damp heat, constant, to IEC 60 068-2-3, Damp heat,


    Original
    DC-13 DC-13, DIL1M DIL0M DIL1AM DIL2AM DILM250 DILM225 DILM400 DILM820 DIL3M80 DIL4M115 PDF

    DIL00M

    Abstract: dil2m DIL0M DIL3AM85 DIL3M80 DIL4AM145 DILM185 DIL1AM DIL2AM DILM225
    Text: Product group data DIL00M General Standards and specifications IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated DC operated Operations x 106 10 Operations 106 10 × Operating frequency, mechanical AC operated Operations/h 7000 DC operated


    Original
    DIL00M 60068-2-3/Damp Page10 DIL00 Daten/img/N/210N0170 DIL00M dil2m DIL0M DIL3AM85 DIL3M80 DIL4AM145 DILM185 DIL1AM DIL2AM DILM225 PDF

    dil3m

    Abstract: 3 phase, 415v and 270 kw motor DIL0M DIL00M wiring diagram contactor 7.5KW 3 phase motor 440v star delta wiring diagram motor dil2m DIL2AM DIL1M
    Text: Issued July 1993 B15333 Controlgear components ÔDIL M range The RS ÔDIL MÕ range of control gear components has been designed to meet modern requirements for heating, lighting and motor control. The components are manufactured to exceed the highest standards required in Europe and North America. They are suitable


    Original
    B15333 A-11kW dil3m 3 phase, 415v and 270 kw motor DIL0M DIL00M wiring diagram contactor 7.5KW 3 phase motor 440v star delta wiring diagram motor dil2m DIL2AM DIL1M PDF

    DIL1M

    Abstract: DIL00AM DIL0M DIL4M115 DILM185 DIL2AM DIL3M80 moeller DIL 10 M dil2m DILM225
    Text: Product group data DIL00AM General Standards and specifications IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated DC operated Operations x 106 10 Operations 106 10 × Operating frequency, mechanical AC operated Operations/h 7000 DC operated


    Original
    DIL00AM 60068-2-3/Damp DIL00 DIL1M DIL00AM DIL0M DIL4M115 DILM185 DIL2AM DIL3M80 moeller DIL 10 M dil2m DILM225 PDF

    dil2m

    Abstract: DIL00M DIL00M-G DIL0M DILM185 DIL00 DIL contactors DIL3AM85 DIL1M dc motors for conveyor belts
    Text: Product group data DIL2M General Standards and specifications IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical AC operated DC operated Operations x 106 10 Operations 106 10 × Operating frequency, mechanical AC operated Operations/h 5000 DC operated Operations/h


    Original
    60068-2-3/Damp DIL00 dil2m DIL00M DIL00M-G DIL0M DILM185 DIL contactors DIL3AM85 DIL1M dc motors for conveyor belts PDF