Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EARTH BONDING SYSTEM Search Results

    EARTH BONDING SYSTEM Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-VHDCIMX200-003 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-003 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 3m Datasheet
    CS-VHDCIMX200-000.5 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-000.5 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male .5m Datasheet
    CS-VHDCIMX200-005 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-005 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 5m Datasheet
    CS-VHDCIMX200-006 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-006 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 6m Datasheet
    CS-VHDCIMX200-001 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-001 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 1m Datasheet

    EARTH BONDING SYSTEM Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Male Earth Bonds Selection Chart and Dimensions

    Abstract: earth bond glenair 80960 PMTC6 80958-M6 PMT10 glenair PMA10 80975 809-74 809-28 80961-M10
    Text: Earth Bonding Glenair Earth Bonding System Male Earth Bonds Selection Chart and Dimensions A Selection Chart Earth Bond Dimensions E B D C Dimensions shown in parenthesis is approximate stud length from top of flange after setting Part Number A B C D E Weight PC


    Original
    PMT10 185mm PMA10 Male Earth Bonds Selection Chart and Dimensions earth bond glenair 80960 PMTC6 80958-M6 PMT10 glenair PMA10 80975 809-74 809-28 80961-M10 PDF

    Female Earth Bonds Selection Chart and Dimensions

    Abstract: Glenair 06324 glenair earth bonding system
    Text: Earth Bonding Glenair Earth Bonding System Female Earth Bonds Selection Chart and Dimensions 2008 Glenair, Inc. CAGE Code 06324 Printed in U.S.A. GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 www.glenair.com


    Original
    PDF

    IEC-60068-2-21

    Abstract: IEC60068-2-52 IEC60068-2-21 80925-M6 IEC-60512-2 80926-M10 80958-M6 IEC60068-14 80961-M10 earth bond glenair 80960
    Text: Earth Bonding System Overview The Glenair Earth Bonding system is a revolutionary method of creating an electrical bond between structures and equipment for the secure passage of high intensity current in case of electrical short circuit. System Benefits •


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Earth Bonding Carbon Fibre Composite Introduction The Glenair Earth Bonding system was first introduced to the Rail and Mass Transit industry for creating a secure electrical grounding system permitting passage of high current in case of electrical short circuit. The method of


    Original
    100mm PDF

    Glenair 06324

    Abstract: Glenair
    Text: Earth Bonding Glenair Earth Bonding System Introduction Overall Features and Performance 2008 Glenair, Inc. CAGE Code 06324 Printed in U.S.A. GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 www.glenair.com


    Original
    PDF

    Typical Performance Values

    Abstract: Glenair 06324 Glenair
    Text: Earth Bonding Glenair Earth Bonding System Typical Performance Values 2008 Glenair, Inc. CAGE Code 06324 Printed in U.S.A. GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 www.glenair.com 71 E-Mail: sales@glenair.com


    Original
    PDF

    PMTC6

    Abstract: pmt10 glenair PMA10 earth bond glenair 80960 80958-M6 PC 80960 80925-M6 80924-M10 80960-M6 10KN
    Text: Glen Earth Bonding The easy to use, reliable earth bond system Drill, Insert, Expand, Connect Lightweight hydraulic setting tool. Requires no welding, impacting, cleaning or surface preparation. Quality repeatable termination even to uneven and curved surfaces.


    Original
    PMT10 185mm PMA10 9-28KN L270X PMTC6 pmt10 glenair PMA10 earth bond glenair 80960 80958-M6 PC 80960 80925-M6 80924-M10 80960-M6 10KN PDF

    SIRIO

    Abstract: contraves alstom wabco tramway metro train citadis ANSALDO MF2000 Oerlikon
    Text: Earth Bonding System Customer Reference United Kingdom Customer Location Project / Application Bombardier Derby Govia, Turbo Star, Electro Star West Coast Cross Country. London Underground - District Line - Train modifications Juniper, West Coast Main Line, Coradia


    Original
    XK150 SIRIO contraves alstom wabco tramway metro train citadis ANSALDO MF2000 Oerlikon PDF

    GPL16

    Abstract: GPL-16-X GPL-34-3
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Grounding Clamp, U-Bolt, Bronze C. Fiber Optic Systems D. Power over Ethernet • Used to ground copper conductor parallel or at a right angle to a rod, tube, or pipe • Made from high strength, electrolytic cast bronze


    Original
    25ength, GPL16 GPL-16-X GPL-34-3 PDF

    Megger

    Abstract: analogue multimeter AVO model 20 manual rugged waterproof buzzer BM501 HD384 BM-500 AVTM21-P8 IEC364 vde 0413 BMM500
    Text: AVO INTERNATIONAL MEGGER BMM500 SERIES • 250V, 500V, 1000V Insulation Ranges • 200mA Continuity Range • Instant Response “ZAP” Buzzer • Voltage Measurement to 600V • MEGGER Intelligent Safety System • Patented backlit DART display • KΩ range for servicing


    Original
    BMM500 200mA AVTM21-P8 Megger analogue multimeter AVO model 20 manual rugged waterproof buzzer BM501 HD384 BM-500 AVTM21-P8 IEC364 vde 0413 PDF

    NTC probe 10K3A1

    Abstract: bsg210 10K3A1-SENSOR 10K3A1 NTC 10k thermal sensor ntc 32.6k HEATSINK PASTE ntc 10mm ZVT-16-IF X10612
    Text: ZVT-16/25-IF ZVT-16/25-IF ZVT-16/25-IF ZVT-16/25-IF CONTROLLER & 10K3A1-SENSOR INSTALLATION CONTROLLER & 10K3A1-SENSOR INSTALLATION X10612 INSTALLATION X10612 INSTALLATION INSTALLATION INSTRUCTIONS 1. 2. 3. 4. 5. 6. 7. Peel adhesive back off dial and fit over 10mm panel hole.


    Original
    ZVT-16/25-IF 10K3A1-SENSOR X10612 ZVT-16-IF ZVT-E-IF-10K3A1 NTC probe 10K3A1 bsg210 10K3A1-SENSOR 10K3A1 NTC 10k thermal sensor ntc 32.6k HEATSINK PASTE ntc 10mm X10612 PDF

    Untitled

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems 837 Universal Beam Grounding Clamp • Universal, fits on a wide range of standard angled and wide flange (parallel) structural steel beams • Provide a mounting pad suitable for a two-hole compression lug


    Original
    GUBC500-6 MIL-STD-202G 305mm) 457mm) GACBJ618U PDF

    Untitled

    Abstract: No abstract text available
    Text: 232E & 232B . . . . . Engineered solutions for the transient environment INDUSTRIAL COMPUTER DATA LINE PROTECTOR APPLICATIONS ● ● ● ● ● RS-232 Transmission Lines Category 3 Systems Control & Monitoring Systems Analog Signal Transmissions Telemetry Outstations


    Original
    RS-232 232E/B PDF

    Untitled

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems C. Fiber Optic Systems D. Power over Ethernet Access Floor Grounding Clamps • Bond mesh common bonding network MCBN conductors to each other and bond the access floor pedestals to the conductors


    Original
    TIA-942 TIA-607-B 150ied HTCT250-2-1 SA-NCCB51. PDF

    Untitled

    Abstract: No abstract text available
    Text: 05060 232B & 232E INDUSTRIAL COMPUTER DATA LINE PROTECTOR APPLICATIONS ✔ RS-232 Transmission Lines ✔ Catagory 3 Systems ✔ Control & Monitoring Systems ✔ Analog Signal Transmissions ✔ Telemetry Outstations IEC COMPATIBILITY EN61000-4 ✔ 61000-4-2 (ESD): Air - 15kV, Contact - 8kV


    Original
    RS-232 EN61000-4) 5/50ns 232E17 PDF

    232B

    Abstract: 232E
    Text: 05060 232B & Only One Name Means ProTek’Tion 232E INDUSTRIAL COMPUTER DATA LINE PROTECTOR APPLICATIONS 232B ✔ RS-232 Transmission Lines ✔ Catagory 3 Systems ✔ Control & Monitoring Systems ✔ Analog Signal Transmissions ✔ Telemetry Outstations


    Original
    RS-232 EN61000-4) 5/50ns 232B 232E PDF

    232B

    Abstract: 232E
    Text: 05060 232B & 232E . . . engineered solutions for the transient environment INDUSTRIAL COMPUTER DATA LINE PROTECTOR APPLICATIONS 232B ✔ RS-232 Transmission Lines ✔ Catagory 3 Systems ✔ Control & Monitoring Systems ✔ Analog Signal Transmissions ✔ Telemetry Outstations


    Original
    RS-232 EN61000-4) 5/50ns 232B 232E PDF

    232B

    Abstract: 232E
    Text: 05060 232B thru 232E INDUSTRIAL COMPUTER DATA LINE PROTECTOR APPLICATIONS ✔ RS-232 Transmission Lines ✔ Catagory 3 Systems ✔ Control & Monitoring Systems ✔ Analog Signal Transmissions ✔ Telemetry Outstations IEC COMPATIBILITY EN61000-4 ✔ 61000-4-2 (ESD): Air - 15kV, Contact - 8kV


    Original
    RS-232 EN61000-4) 5/50ns 232B 232E PDF

    mtl 7796

    Abstract: MTL7787 MTL*787 MTL 7756ac mtl7760ac MTL7755AC MTL*706 7755ac mtl7756ac safety barrier mtl7756AC
    Text: MTL7700 Series Shunt-diode safety barriers Instruction Manual INM7700 INM7700-5 Apr 2007 ii CONTENTS PAGE 1 OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1


    Original
    MTL7700 INM7700 INM7700-5 mtl 7796 MTL7787 MTL*787 MTL 7756ac mtl7760ac MTL7755AC MTL*706 7755ac mtl7756ac safety barrier mtl7756AC PDF

    A005

    Abstract: transistor k 4212 copper bond wire
    Text: Transistor Chip Use Application Note A005 Part I. Assembly Considerations 1.0 Chip Packaging for Shipment 2.0 Handling Chips with Tweezers 1.1 General Unfortunately, both silicon and GaAs materials are quite brittle GaAs is more so and the sharp edges of the


    Original
    5091-8802E 5968-3242E A005 transistor k 4212 copper bond wire PDF

    transistor k 4212 fet

    Abstract: Silicon Bipolar Transistor Hewlett-Packard transistor k 4212
    Text: Transistor Chip Use Application Note A005 Part I. Assembly Considerations 1.0 Chip Packaging for Shipment 1.1 General Hewlett-Packard transistor chips are shipped in chip carriers with a clear or black elastomer as a carrier medium. There are up to 100 chips


    Original
    5091-8802E 5968-3242E transistor k 4212 fet Silicon Bipolar Transistor Hewlett-Packard transistor k 4212 PDF

    J6301

    Abstract: 4mm banana plug socket earth J6303 earth stud J6310 binding post terminal post banana 4mm 1 WATT resistor
    Text: EARTH BONDING POINT PLUGS - UK STYLE EARTHING POINTS BS EN 100 015-1 distinguishes betw een Earth Facility and Earth Bonding Point. An Earth Facility EF usually distributes the electrical mains earth within an EPA. In rare cases where the mains earth is unsuitable, the Earth


    OCR Scan
    JB591 J6303 J6310 J6330 J6341 J6301NR J6301 J6321 JB596 4mm banana plug socket earth earth stud binding post terminal post banana 4mm 1 WATT resistor PDF

    Untitled

    Abstract: No abstract text available
    Text: Introduction Geo-Marine Interconnect Solutions At a Glance Harsh Environment Products from a One-of-a-Kind Supplier: Glenair Glenair's GroundControl Earth Bonding Sys­ tem provides a fast, one-man solution to electrical Glenair's application engineers have worked di­


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Disconnect Terminal Blocks for Test Purposes, 1 Ground Earth Conductor Disconnect Terminal Blocks 132 Side-entry 0.2 - 6 m m 2 AWG 24 - 10 300 V, 30 A TO 400 V/6 kV/3 O 41 A 300 V, 40 A 0 Terminal block width 8 mm / 0.315 in > 62a 12 - 13 mm / 0.49 in 0.2 - 6 m m 2


    OCR Scan
    PDF