Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IEC60079 Search Results

    IEC60079 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    FET521

    Abstract: FEP315 ABB FEP315 FEP325 FET325 FET321 FEP515 FET3251 abb fet 521 FET525
    Text: SM/FEX300/FEX500/ATEX/IECEX-EN ProcessMaster / HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Safety instructions for electrical apparatus in potentially explosive areas, in accordance with Directive 94/9/EC ATEX and IEC60079-0 (IECEx) Electromagnetic Flowmeter


    Original
    PDF SM/FEX300/FEX500/ATEX/IECEX-EN FEX300, FEX500 94/9/EC IEC60079-0 FET521 FEP315 ABB FEP315 FEP325 FET325 FET321 FEP515 FET3251 abb fet 521 FET525

    FET321 MANUAL

    Abstract: optoacoplador FET321 FET521 FEP315-100A1S1D2B0A1A0M1A1C1 FEP315 FET3251 transformador FET325 FET325 manual
    Text: SM/FEX300/FEX500/ATEX/IECEX-X1 ProcessMaster / HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche gemäß Richtlinie 94/9/EG ATEX und IEC60079-0 (IECEx) Magnetisch-induktiver Durchflussmesser


    Original
    PDF SM/FEX300/FEX500/ATEX/IECEX-X1 FEX300, FEX500 94/9/EG IEC60079-0 94/9/EC 94/9/CE seg00/ATEX/IECEX-X1 3KXF231300R4893 FET321 MANUAL optoacoplador FET321 FET521 FEP315-100A1S1D2B0A1A0M1A1C1 FEP315 FET3251 transformador FET325 FET325 manual

    IEC60079-0

    Abstract: Baseefa09ATEX0232X IEC60079-15
    Text: Conns4 - ATEX 2010:Conns4 - ATEX Bucc pages 2005 8/6/10 16:30 Page 13 EXPLORA IP68 EXPLORA EXPlora Independently tested for compliance to ATEX standards for use in Zone 2 and Zone 22 environments, the new EXP series is manufactured from a tough, high grade UL94V-0 rated Polyester material and provides


    Original
    PDF UL94V-0 Baseefa09ATEX0232X. 600Vac/dc 430Vac/dc 250Vac/dc 20-22mm 18-20mm 16-18mm 14-16mm EXP-0911/07/P/3 IEC60079-0 Baseefa09ATEX0232X IEC60079-15

    Untitled

    Abstract: No abstract text available
    Text: DeltaV SIS Product Data Sheet October 2014 – Page 1 DeltaV SIS with Electronic Marshalling DeltaV SIS with Electronic Marshalling The DeltaV SIS process safety system has the world’s first CHARMs Smart SIS Logic Solver, using the power of predictive


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Product Data Sheet September 2014 00813-0100-4702, Rev JA Rosemount 702 Wireless Discrete Transmitter  An installation-ready solution that provides dual channel, discrete input, discrete output, or leak detection input options  Discrete single or dual switch input with logic for limit contact and opposing contact applications


    Original
    PDF

    BS2779 BSP THREAD

    Abstract: IEC60079-14 EX-35-B-1-0-20-M20 M32 nylon cable gland 602 GB Series AMPHENOL dts01 galvanised conduit hazardous area ZP-C-2520-12 Radsok Amphenol Radsok
    Text: Amphenol Cable Glands and Cord Grips 12-055 Amphenol Table of Contents Introduction Amphenol® Cable Glands Page Number 1 2-3 ATEX Approved Glands Featuring Elastometric Seals EX-20 4-5 EX-25 6-7 EE-30 8-9 EX-35 10-11 EX-40 12-13 EX-45 14-15 EE-RG 16-17


    Original
    PDF EX-20 EX-25 EE-30 EX-35 EX-40 EX-45 EX-50 EX-55 EX-60 EX-65 BS2779 BSP THREAD IEC60079-14 EX-35-B-1-0-20-M20 M32 nylon cable gland 602 GB Series AMPHENOL dts01 galvanised conduit hazardous area ZP-C-2520-12 Radsok Amphenol Radsok

    PAR/230VAC

    Abstract: No abstract text available
    Text: -20 -10 20 30 40 50 Surrounding air temperature o C 10 60 1 Figure 7 10 20 30 40 50 60 70 80 90 100 110 70 Power Derating for PSU in Horizontal and Vertical Position Figure 6 Figure 5 Figure 4 Figure 3 Figure 2


    Original
    PDF 120W1P EOE12010249 DRP024V120W1BA 1AC/24VDC/5A PAR/230VAC

    Untitled

    Abstract: No abstract text available
    Text: TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 240W 3 Phase / DRP024V240W3AA Highlights & Features – – – – – – – – – Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed


    Original
    PDF DRP024V240W3AA 2011/65/EU

    Untitled

    Abstract: No abstract text available
    Text: TECHNICAL DATASHEET CliQ II DIN Rail Power Supply 24V 480W 1 Phase / DRP024V480W1B□ Highlights & Features – – – – – – – – – – Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation


    Original
    PDF DRP024V480W1Bâ DRP024V480W1BN) DRP024V480W1BA) 2011/65/EU

    Untitled

    Abstract: No abstract text available
    Text: CliQ II DIN Rail Power Supply 48V 120W 1Phase Features RoHS Directive 2011/65/EU Compliant Efficiency >89%Typ. Over load protection Over voltage protection Over temperature protection Expected life time : 10 Years Power boost 150% for 5 seconds Compact design for easy handling and


    Original
    PDF 2011/65/EU DRR-20A DRR-40A DRP048V120W1BA

    TSP-BFM24

    Abstract: en6155828 230vac to 12vdc smps tsp 600-124
    Text: INDUSTRIAL POWER SUPPLIES TSP-SERIES Operating Instructions ♦ TSP 070-112 ♦ TSP 090-124 ♦ TSP 090-124N ♦ TSP 140-112 ♦ TSP 180-124 ♦ TSP 360-124 ♦ TSP 600-124 Date: 10 October 2005 Jenatschstrasse 1 Tel: +41 43 311 4511 sales@traco.ch Fax: +41 43 311 4545 www.tracopower.com Issue: 2.1


    Original
    PDF 090-124N CH-8002 TSP-WMK01) TSP-WMK02) TSP-BFM24 en6155828 230vac to 12vdc smps tsp 600-124

    Untitled

    Abstract: No abstract text available
    Text: OPI2000MTH This component is RoHS compliant High Speed Opto Isolator Through Hole ATEX & IECEx Certified Pb The OPI 2000MTH High Speed Optically Coupled Isolator consists of a High Speed Infrared emitter coupled to a silicon photo I.C. The unit is designed for applications requiring high voltage


    Original
    PDF OPI2000MTH 2000MTH BAS01ATEX1285U/5 0021U/4 EN60079-0 EN60079-11 EN60079-26

    Untitled

    Abstract: No abstract text available
    Text: TECHNICAL DATASHEET CliQ II Buffer Module 24V 20A / DRB-24V020ABA Highlights & Features – – – – – – – – – – Full corrosion resistant Aluminium chassis Long minimum buffering time of 250ms @ 24V/20A Can connect in parallel to increase buffering time


    Original
    PDF DRB-24V020ABA 250ms 4V/20A 2011/65/EU

    Untitled

    Abstract: No abstract text available
    Text: CliQ II DIN Rail Power Supply 48V 60W 1Phase Features RoHS Compliant Efficiency > 89%Typ. Over load protection Over voltage protection Meet Energy Star Level V Over temperature protection Expected life time : 10 Years Power boost 150% for 5 seconds Compact design for easy handling


    Original
    PDF DRR-20A DRR-40A DRP048V060W1BA

    Untitled

    Abstract: No abstract text available
    Text: OPI1264 Series This component is RoHS compliant Optically Coupled Isolators ATEX &IECEx CERTIFIED Pb The OPI1264A/B/C/D are a family of optically coupled isolators, each consisting of a infrared light emitting diode, coupled to an NPN silicon phototransistor sealed in an injection moulded


    Original
    PDF OPI1264 OPI1264A/B/C/D ratio-100 0021U/4 BAS01ATEX1278U/5 EN60079-0 EN60079-11 EN60079-26 94/9/EC 2011/65/EU.

    piezoelectric actuator plate vibration machining

    Abstract: PT100 temperature sensor ABB motor
    Text: Signal Isolating Converters, Trip Amplifiers and Displays Catalogue 2012/2013 Analogue Signal Conditioning The World of Industrial Connectivity As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal


    Original
    PDF 1327190000/07/2012/SMDM piezoelectric actuator plate vibration machining PT100 temperature sensor ABB motor

    IP 8082 BL

    Abstract: 30A fuse ENEC Baseefa09ATEX0232X A/ATEX
    Text: Product Catalogue Issue No 83 Europe Elektron Technology Melville Court, Spilsby Road, Romford, Essex, England RM3 8SB Tel: Fax +44 0 1708 343800 +44 (0)1708 376544 Email: Web: europe@elektron-technology.com www.elektron-bulgin.com The Americas Elektron Technology


    Original
    PDF

    Baseefa09ATEX0232X

    Abstract: No abstract text available
    Text: EXP wiring v1.0:Layout 1 1/2/10 12:25 Page 1 EXPlora Zone 2 Hazardous Area Connector Information and Specification IMPORTANT - PLEASE READ GB Ratings and Approvals Before using the connector, it is important that these instructions are carefully read and understood to ensure the connector system is completely water tight and


    Original
    PDF EXP-0911/xx/x, EXP-A911/xx/x, EXP-0921/xx/x, EXP-A921/xx/x EXP-0931 EXP-0941 Baseefa09ATEX0232X

    l 7803 3V Positive Voltage Regulator metal ca

    Abstract: Solar Charge Controller mppt ic Solar mppt schematic mppt solar charger schematic 12V Solar Charge Controller mppt mppt charge controller schematic mppt Charge Controller design and circuit schematic diagram MPPT microcontroller solar charger schematic 24V schematic diagram MPPT
    Text: LINEAR TECHNOLOGY SEPTEMBER 2009 IN THIS ISSUE… COVER ARTICLE Power Management IC Digitally Monitors and Controls Eight Supplies .1 Andrew Gardner VOLUME XIX NUMBER 3 Power Management IC Digitally Monitors and


    Original
    PDF SE-164 1-800-4-LINEAR l 7803 3V Positive Voltage Regulator metal ca Solar Charge Controller mppt ic Solar mppt schematic mppt solar charger schematic 12V Solar Charge Controller mppt mppt charge controller schematic mppt Charge Controller design and circuit schematic diagram MPPT microcontroller solar charger schematic 24V schematic diagram MPPT

    IEC-79

    Abstract: IEC60079-11 IRLR2906 IEC79-11 INTRINSIC SAFE CIRCUIT LT4356 IEC-79 fuse DC1018 LT4356S power resistor encapsulated IRLR2908
    Text: DESIGN FEATURES L Surge Stopper IC Simplifies Design of Intrinsic Safety Barrier for Electronics Destined for Hazardous Environments by Murphy Pickard, Hach Co. Introduction As applications for electronic instrumentation proliferate, an increasing number of applications require equipment safe enough to operate in


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: TECHNICAL DATASHEET CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features – – – – – – – – – Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed


    Original
    PDF DRP024V120W1AA 2011/65/EU 121ces

    Untitled

    Abstract: No abstract text available
    Text: -20 -20 -10 -10 10 20 30 40 50 20 30 40 50 Surrounding air temperature o C 10 Surrounding air temperature (o C) 60 60 70 70 80 80 1 Figure 7 10 20 30 40 50 60 70 80 90 100 110 10 20 30 40 50 60 70 80 90


    Original
    PDF 240W1P EOE12010250 DRP024V240W1BA 1AC/24VDC/10A

    Untitled

    Abstract: No abstract text available
    Text: TECHNICAL DATASHEET CliQ DIN Rail Power Supply 12V 30W 1 Phase / DRP012V030W1A□ Highlights & Features – – – – – – – – – – Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed


    Original
    PDF DRP012V030W1Aâ DRP012V030W1AZ) DRP012V030W1AY) 2011/65/EU

    LCIE 07 ATEX 0004 U

    Abstract: 24vdc 2a smps EN61558-2-4 LCIE60058407-559419 tsp 090-124 ot 112 IEC60079-1 en61558 CSA-C22 16VDC
    Text: INDUSTRIAL POWER SUPPLIES TSP-SERIES Operating Instructions ♦ TSP 070-112 ♦ TSP 090-124 ♦ TSP 090-124N ♦ TSP 140-112 ♦ TSP 180-124 ♦ TSP 360-124 ♦ TSP 600-124 ♦ TSP 090-148 ♦ TSP 180-148 ♦ TSP 360-148 ♦ TSP 600-148 Date: 28 March 2008


    Original
    PDF 090-124N CH-8002 TSP-WMK01) 090-1xx, 180-1xx TSP-WMK02) LCIE 07 ATEX 0004 U 24vdc 2a smps EN61558-2-4 LCIE60058407-559419 tsp 090-124 ot 112 IEC60079-1 en61558 CSA-C22 16VDC