Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IEC61558 Search Results

    IEC61558 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    TOP249Y

    Abstract: TDA16837 12 pin flyback transformer PHILIPS philips flyback transformer 14 pin flyback transformer philips TOP248Y ETD44 myrra 74070 Diodes S4
    Text: FLYBACK TRANSFORMER • • • • • • SIZE ETD44 • 4 OUTPUTS : 5+12 / 5+12v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 8mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    ETD44 IEC950, IEC335, IEC61558 UL94-V0 132kHz 265Vrms OP249Y OP248Y TOP249Y TDA16837 12 pin flyback transformer PHILIPS philips flyback transformer 14 pin flyback transformer philips TOP248Y ETD44 myrra 74070 Diodes S4 PDF

    TNY266

    Abstract: 74015 12 pin flyback transformer POWER INTEGRATIONS tny266 transformer IC 74015 myrra TNY266 Power Integrations TOP242P TNY266 application
    Text: FLYBACK TRANSFORMER • • • • • • SIZE E16 • 3 OUTPUTS : 5 / 15 / 24v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 TNY266 265Vrms OP242P TNY266 74015 12 pin flyback transformer POWER INTEGRATIONS tny266 transformer IC 74015 myrra TNY266 Power Integrations TOP242P TNY266 application PDF

    TNY266

    Abstract: myrra 74014 tny266 transformer TNY266 Power Integrations E16 10 pin transformers TNY266 application 12 pin flyback transformer IEC335 myrra E16
    Text: FLYBACK TRANSFORMER SIZE E16 • 2 OUTPUTS : 2 x 24v • • • • • • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 TNY266 265Vrms OP242P TNY266 myrra 74014 tny266 transformer TNY266 Power Integrations E16 10 pin transformers TNY266 application 12 pin flyback transformer IEC335 myrra E16 PDF

    TNY254

    Abstract: TNY254 equivalent myrra 74093 data sheet of 12v transformer transformer e16 E16 10 pin transformers IEC950 Power Integrations IEC335
    Text: TRANSFORMER FOR TINYSWITCH SIZE E16 • SINGLE OUTPUT : 5 or 12v • • • • • Primary / Secondary Insulation ≥ 4000V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 70°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 TNY254 265Vrms 44kHz TNY254 TNY254 equivalent myrra 74093 data sheet of 12v transformer transformer e16 E16 10 pin transformers IEC950 Power Integrations IEC335 PDF

    el19 transformer

    Abstract: TOP243P myrra el19 74023 10 pin flyback transformer 12 pin flyback transformer Diodes S4 flyback transformer construction Integrations
    Text: FLYBACK TRANSFORMER • • • • • • SIZE EL19 • 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 60°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 OP243P 265Vrms 132kHz el19 transformer TOP243P myrra el19 74023 10 pin flyback transformer 12 pin flyback transformer Diodes S4 flyback transformer construction Integrations PDF

    8 pin e25 transformer

    Abstract: 74032 TOP244Y TOP244P IC 74032 flyback transformer 74030 VIPER50 application note TOP244Y application TOP244P IC myrra
    Text: FLYBACK TRANSFORMER SIZE E25 • 3 or 1 OUTPUTS : 5+12/12v or 24v • • • • • • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    12/12v IEC950, IEC335, IEC61558 UL94-V0 OP244P 265Vrms 132kHz OP244Y 8 pin e25 transformer 74032 TOP244Y TOP244P IC 74032 flyback transformer 74030 VIPER50 application note TOP244Y application TOP244P IC myrra PDF

    74003

    Abstract: 74001 74000 adc datasheets E16 74000 74002 7400-1 IEC335 IEC61558
    Text: 44 E16 • 2 Outputs: 5 & 12V, Single Output: 5 or 12V Size • Primary / Secondary Insulation > 4000V • Primary / Auxiliary Insulation > 1500V • Creepage distance Primary / Secondary > 6mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 74003 74001 74000 adc datasheets E16 74000 74002 7400-1 IEC335 PDF

    IEC335

    Abstract: IEC61558
    Text: Size E16 • Single Output: 5 or 12V 44 • Primary / Secondary Insulation > 4000V • Creepage distance Primary / Secondary > 6mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation • Exclusively uses UL94-V0 listed materials


    Original
    IEC950, IEC335, IEC61558 UL94-V0 IEC335 PDF

    74090

    Abstract: transformer for TNY253 IC 74090 tny253 myrra E16 transformer transformer e16 74091 data sheet of 12v transformer IEC61558
    Text: TRANSFORMER FOR TINYSWITCH • • • • • SIZE E16 • SINGLE OUTPUT : 5 or 12v Primary / Secondary Insulation ≥ 4000V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 85°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    IEC950, IEC335, IEC61558 UL94-V0 TNY253 265Vrms 44kHz 74090 transformer for TNY253 IC 74090 tny253 myrra E16 transformer transformer e16 74091 data sheet of 12v transformer PDF

    74081

    Abstract: IEC335 7408-1 EF20 IEC61558 74082 EF20 6 8
    Text: Size EF20 • 2 or 3 Outputs: 5/5v or 12/12v or 3.3+5/12V 44 • Primary / Secondary Insulation > 4000V • Primary / Auxiliary Insulation > 1500 V • Creepage distance Primary / Secondary > 8 mm / > 6 mm • Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    12/12v 5/12V IEC950, IEC335, IEC61558 UL94-V0 74081 IEC335 7408-1 EF20 74082 EF20 6 8 PDF

    erl-28

    Abstract: erl28 top246y IC TOP246Y myrra AC Transformer 12V myrra IEC61558 74043 IEC950 INTEGRATIONS
    Text: FLYBACK TRANSFORMER SIZE ERL28 • 5 OUTPUTS : 3.3 / 5 / 12 / 18 / 30v • • • • • • Primary / Secondary Insulation ≥ 4000V Primary / Auxiliary Insulation ≥ 1500V Creepage distance Primary / Secondary ≥ 6mm Ambient temperature < 50°C Construction conforms to IEC950, IEC335, IEC61558 for reinforced insulation


    Original
    ERL28 IEC950, IEC335, IEC61558 UL94-V0 OP246Y 265Vrms 132kHz erl-28 erl28 top246y IC TOP246Y myrra AC Transformer 12V myrra 74043 IEC950 INTEGRATIONS PDF

    EE16

    Abstract: No abstract text available
    Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: Properties Test conditions Inductance 100 kHz/ 100 mV Turns ratio C Schematic: Value Unit Tol. µH ±10% L 1500 n 160 : 7 : 7 : 18 0.8 A typ. ±3% Saturation current |ΔL/L| < 20%


    Original
    PDF

    IEC61558-1

    Abstract: IEC61558 enclosure RAL7035 EN61558-1 IEC61558-2-13 RAL7032 transformer 400V EN61558
    Text: TRD Series three-phase transformer controllers General remarks: The TRD series of transformer controllers for three phase AC fans and motors provide energy saving speed control without the creation of additional motor noise which you get with most electronic controllers. Vacuum impregnation also reduces


    Original
    TRD14 RAL7035) RAL7032) IEC61558-1 IEC61558 enclosure RAL7035 EN61558-1 IEC61558-2-13 RAL7032 transformer 400V EN61558 PDF

    Untitled

    Abstract: No abstract text available
    Text: A Dimensions: [mm] B Recommended land pattern: [mm] D Electrical Properties: C Schematic: Properties Test conditions Value Unit Inductance 100 kHz/ 100 mV Leakage inductance 100 kHz/ 100 mV Tol. L 750 µH min. 4.0 µH max. DC Resistance 1 LS RDC 1100 mΩ max.


    Original
    PDF

    81591

    Abstract: IEC61558 VDE0570 81591-P2S2 81589-P2S2
    Text: Toroidal Transformer Data Sheet 30-Dec-2009 Open Style, with leads, 2x115V Primary, 120VA 115V 0V 115V 0V Brown Red Vsec Blue Black 0V Green Yellow Vsec Violet Orange 0V RS Code No. RS Part No. Primary 2x115V @ 50/60Hz Secondary 2 x Vsec, @ 60VA Each Suitable for Series/Parallel Connection


    Original
    30-Dec-2009 2x115V 120VA 2x115V 50/60Hz 81587-P2S2 81588-P2S2 81589-P2S2 81590-P2S2 67and 81591 IEC61558 VDE0570 81591-P2S2 81589-P2S2 PDF

    VDE0570

    Abstract: IEC61558 insulated copper wire 0.5mm
    Text: Toroidal Transformer Data Sheet 20-Aug-2009 Open Style,LVL,with leads, 230V Primary,105VA 230V Brown Red Vsec Primary 230V @ 50/60Hz Secondary Vsec, @105VA 120°C Red 0V Blue RS Code No. 0V RS Part No. 671-9198 81605-P1S1 Full Load Vsec [V] Rated Current per Sec [A]


    Original
    20-Aug-2009 105VA 50/60Hz 81605-P1S1 EN61558 VDE0570 IEC61558 UL506 insulated copper wire 0.5mm PDF

    40VA

    Abstract: 80VA IEC61558 VDE0570 Toroidal transformer P2S2
    Text: Toroidal Transformer Data Sheet 30-Dec-2009 Open Style, with leads, 2x115V Primary, 80VA 115V 0V 115V 0V Brown Red Vsec Blue Black 0V Green Yellow Vsec Violet Orange 0V RS Code No. RS Part No. Primary 2x115V @ 50/60Hz Secondary 2 x Vsec, @ 40VA Each Suitable for Series/Parallel Connection


    Original
    30-Dec-2009 2x115V 2x115V 50/60Hz 81581-P2S2 81582-P2S2 81583-P2S2 81584-P2S2 671-d EN61558 40VA 80VA IEC61558 VDE0570 Toroidal transformer P2S2 PDF

    Untitled

    Abstract: No abstract text available
    Text: CUSTOMER TERMINAL RoHS LEAD Pb —FREE S n96% , Ag4% Yes Yes r-|y~ more than you e xpect IVidcom =tb_ 7508112510 WURTH ELEKTRONIK ELECTRICAL SPECIFICATIONS 25°C unless otherwise noted: PAR AM ETER DOT LOCATES TERM. #1 TEST 1 -3 C O N D IT IO N S VALUE


    OCR Scan
    10kHz, 800uH PDF

    Untitled

    Abstract: No abstract text available
    Text: CUSTOMER TERMINAL RoHS LEAD Pb —FREE Sn96%, Ag4% Yes Yes W U R T H E L E K T R O N IK ELECTRICAL SPECIFICATIONS 25°C unless otherwise noted: TEST 1 .2 3 4 o h m s ±10% D .C . R E S IS T A N C E 4 -5 @ 20”C 0 .1 9 7 o h m s ±10% @ 2 0°C 0 .0 9 2 8


    OCR Scan
    770uH 400VDC. PDF

    Untitled

    Abstract: No abstract text available
    Text: CUSTOMER TERMINAL RoHS LEAD Pb —FREE S n96% , Ag4% Yes Yes _cih= more than you e xpect IVidcom =0=k 750811643 WURTH ELEKTRONIK ELECTRICAL SPECIFICATIONS 25°C unless otherwise noted: =n^ PAR AM ETER DOT LOCATES TERM. #1 TEST 1 -3 C O N D IT IO N S VALUE


    OCR Scan
    10kHz, 800uH 100kHz, PDF

    Untitled

    Abstract: No abstract text available
    Text: CUSTOMER TERMINAL RoHS LEAD Pb —FREE S n96% , Ag4% Yes Yes _cih= more than you e xpect IVidcom =0=k 750811914 WURTH ELEKTRONIK ELECTRICAL SPECIFICATIONS 25°C unless otherwise noted: =n^ PAR AM ETER LOT CODE & D.C. RESISTANCE DATE CODE D.C. RESISTANCE


    OCR Scan
    10kHz, PDF

    Untitled

    Abstract: No abstract text available
    Text: RoHS L E A D P b -F R E E S n 96% , Ag4% Yes Yes more than you expect TERM. NO.’s FOR REF. ONLY DOT LOCATES TERM. LOT CODE & DATE CODE r J ^ .1 9 7 ( 3 ) [5 .0 0 ] X- 100kHz TEST VALUE CO NDITIONS D.C. RESISTANCE 1-2 D.C. RESISTANCE 3-5 20“C 5 .0 5 o h m s ±10%


    OCR Scan
    10kHz, IEC61558-- 400VDC. PDF

    MARKING CODE l23

    Abstract: marking code 15b 555mA IEC61558
    Text: CUSTOMER TERMINAL RoHS L E A D P b -F R E E S n 96% , Ag4% Yes Yes PA R T M U S T S U RFACE A 0 .0 2 5 IN S E R T F U L LY TO IN R E C O M M E N D E D more than you expect A LTE R N A T E GRID DOT S Q .(9 ) M A R K IN G LO C ATES D E T A IL TER M . T E ST


    OCR Scan
    555mA IEC61558â 400VDC. PKG-0058 MARKING CODE l23 marking code 15b 555mA IEC61558 PDF

    WE-MIDCOM transformer

    Abstract: IEC61558 WE-MIDCOM 4000VAC 1310kHz
    Text: C U S TO M E R TE R M IN A L S n96% , Ag4% R oHS L E A D P b -F R E E Y es Yes IVidcam PART MUST INSERT FULLY TO SURFACE A IN RECOMMENDED GRID 0 .0 2 4 ( 9 ) | _ A_ [•60] ELECTRICAL SPECIFICATIONS DOT LOCATES TERM. #1 . 0 9 0 / . 11 5 [2 .2 9 /2 .9 2 ]


    OCR Scan
    115kHz 500mA IEC61558â 600VDC. 239VAC. PKG-0103 EE13/7/4 WE-MIDCOM transformer IEC61558 WE-MIDCOM 4000VAC 1310kHz PDF