Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    KFD2 Search Results

    SF Impression Pixel

    KFD2 Price and Stock

    PEPPERL+FUCHS GmbH KFD2-SR2-2.W.SM

    CONTROL EQUIPMENT
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey KFD2-SR2-2.W.SM Box 1
    • 1 $358.01
    • 10 $358.01
    • 100 $358.01
    • 1000 $358.01
    • 10000 $358.01
    Buy Now

    PEPPERL+FUCHS GmbH KFD2-STC5-1

    K-System Non-I.s. |Pepperl+Fuchs Pa KFD2-STC5-1
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark KFD2-STC5-1 Bulk 1
    • 1 $359.64
    • 10 $333.95
    • 100 $296.4
    • 1000 $296.4
    • 10000 $296.4
    Buy Now

    PEPPERL+FUCHS GmbH KFD2-GS-1.2W

    K-System Non-I.s. |Pepperl+Fuchs Pa KFD2-GS-1.2W
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark KFD2-GS-1.2W Bulk 1
    • 1 $553.28
    • 10 $509.6
    • 100 $413.51
    • 1000 $413.51
    • 10000 $413.51
    Buy Now
    RS KFD2-GS-1.2W Bulk 4 1
    • 1 $609.4
    • 10 $578.93
    • 100 $548.46
    • 1000 $548.46
    • 10000 $548.46
    Buy Now

    PEPPERL+FUCHS GmbH KFD2-SL2-EX2

    K-System Binary |Pepperl+Fuchs Pa KFD2-SL2-EX2
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark KFD2-SL2-EX2 Bulk 1
    • 1 $836
    • 10 $770
    • 100 $624.8
    • 1000 $624.8
    • 10000 $624.8
    Buy Now

    PEPPERL+FUCHS GmbH KFD2-ELD-EX16

    K-System Miscellaneous |Pepperl+Fuchs Pa KFD2-ELD-EX16
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark KFD2-ELD-EX16 Bulk 1
    • 1 $1491.12
    • 10 $1325.44
    • 100 $1299.28
    • 1000 $1299.28
    • 10000 $1299.28
    Buy Now

    KFD2 Datasheets (3)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    KFD2-SR2-Ex1.W Unknown Transformer Isolated Barriers Original PDF
    KFD2-SR2-Ex2.W Unknown Transformer Isolated Barriers Original PDF
    KFD2-SRA-Ex4 Pepperl+Fuchs Transformer Isolated Barriers Original PDF

    KFD2 Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    namur NE 21

    Abstract: MF740 DIN19234 kfd2-sr-ex2 la 7610
    Text: A U T O M A T I O N C Transformer Isolated Barrier KFD2-SR2-Ex2.W _Output: Relay € - Dual Channel Input I EEx ia IIC Input II EEx ia IIG - Hazardous Field Circuit EEx ia MC and Class I, Div 1, Groups A-G - DC 24 V Nominal Power Supply


    OCR Scan
    14AWG) namur NE 21 MF740 DIN19234 kfd2-sr-ex2 la 7610 PDF

    KFD2-STC4-EX2

    Abstract: kfd2-stc4 abb SMART temperature Transmitter transmitter calibration certificate foxboro fisher-rosemount hazardous area Endress namur NE 21 BY260V
    Text: SMART Transmitter Power Supply KFD2-STC4-Ex2 - Input EEx ia IIC ? - DC 24 V power supply Input ΙΙ EEx ia IIC ? J J 2-wire transmitters - EMC per NAMUR NE 21 - LED per NAMUR NE 44 The SMART transmitter power supplies supply a 2-wire SMART transmitter within a


    Original
    PDF

    KFD2-SR2-Ex1.W

    Abstract: IEC 60947-5-6 kfd2-eb2 NE44 IEC 60947-5-6 NAMUR 60947-5-6 kfd2 Pepperl Fuchs kfd2 EN50-020 Ignition Transformer
    Text: Transformer Isolated Barriers KFD2-SR2-Ex1.W Output: Relay Input I EEx ia IIC 3400 Ω ≤ R ≤ 2 kΩ 1+ Switch S3 in position I without SC • • • • 1-channel Control circuit EEx ia IIC Reversible mode of operation 1 relay output with 1 changeover


    Original
    PDF

    KFD2-EB-D2A.B

    Abstract: kfd2 ji-30 via 1618 T4 621
    Text: KFD2-EB.D2A.B Power Rail power feed module for redundant supply, with bus terminals Connection Supply 8+ • 24 V DC supply voltage • Device installation permissible in zone 2 • Supply current ≤ 2 A • Bus access via terminals • Redundant supply • Fault signal output with adjustable


    Original
    PDF

    kfd2

    Abstract: Pepperl Fuchs kfd2 terminal EEx e II T6 SD 621 transistor DIN EN 50014 STANDARD mh 776 Pepperl Fuchs kfd2 sl2 T4 621 99-ATEX 00ATEX
    Text: Current limit 35 mA • 1-channel • Output EEx ia IIC • Device installation permissible in zone 2 • 24 V DC nominal supply voltage • Usable up to SIL 3 acc. to IEC 61508 2- 1+ 2- 1+ Standard type KFD2-SL2-Ex1.B Function The KFD2-SD-Ex1.48 and the KFD2-SD-Ex1.48.90A receives its


    Original
    PDF

    Ex-94

    Abstract: kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234
    Text: C Transformer Isolated Barrier KFD2-SR2-Ex1.W _Output: Relay € - Single Channel Input EEx ia IIC - Hazardous Field Circuit EEx ia IIC and Class I, Div 1,Groups A-G - DC 24 V Nominal Power Supply ra 1+ - Selectable Mode of Operation


    OCR Scan
    14AWG) Ex-94 kfd2-sr-ex1 KFD2-SR2-EX1.W khd2-sr namur NE 21 DIN19234 PDF

    EX-94

    Abstract: kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5
    Text: P R O Z E S S A U T O M A T I O N Trennschaltverstärker K -SR2-Ex1.W Ausgang: Relais Eingang EEx ia IIC - 1-kanalig - Steuerstromkreis EEx ia IIC 1+ 3- - 1 Signalausgang mit 1 Wechsler - EMV gemäß NAMUR NE 21 Schalter S3 in Pos. I 10 kΩ 1+ 3- KFD2-SR2-Ex1.W


    Original
    Signalgebe50 EX-94 kha6-sr2-ex KHA6 namur NE 21 KHA6-SR2-Ex1.W KHA5-S kfd2-sr-ex1 KFD2-SR2-EX1.W DIN19234 KFA5 PDF

    kfd2-eb2

    Abstract: kfd2-cd-ex1.32 namur NE 93 kfd2 DIN 50014 ATEX 014 KFD2-CD valve positioners 0/kfd2-cd-ex1.32
    Text: KFD2-CD-Ex1.32 Current/voltage repeater Connection • • • • • • • • • 1-channel Output EEx ia IIC 24 V DC supply voltage Device installation permissible in zone 2 Conversion of current/voltage or voltage/current Elevation/Suppression of the "life


    Original
    PR-03 UPR-03 kfd2-eb2 kfd2-cd-ex1.32 namur NE 93 kfd2 DIN 50014 ATEX 014 KFD2-CD valve positioners 0/kfd2-cd-ex1.32 PDF

    kfd2-stc1-ex1

    Abstract: kfd2 fisher-rosemount Ex-94 namur NE 93 namur NE 21 STT01 ST-T01 bailey transmitter abb SMART temperature Transmitter
    Text: SMART Transmitter Power Supplies Hazardous area KFD2-ST*1-Ex1* Input EEx ia IIC SMART transmitter SMART communicator 1-channel Input EEx ia IIC; U0 = 28V 24 V DC nominal supply voltage SMART capable up to 12 kHz -1 dB EMC acc. to NAMUR NE 21 1+ 3- 1+ + -


    Original
    PDF

    kfd2-eb2

    Abstract: NE44 atex 2035 kfd2 kfd2-sot2-ex2 IEC 60947-5-6 pepperl
    Text: Switch Amplifier KFD2-SOT2-Ex2.IO Assembly Features • • • • • • • 2-channel isolated barrier 24 V DC supply Power Rail Dry contact or NAMUR inputs Isolated passive transistor output, non-polarized Line fault detection (LFD) Reversible mode of operation


    Original
    UPR-03 UPR-03 kfd2-eb2 NE44 atex 2035 kfd2 kfd2-sot2-ex2 IEC 60947-5-6 pepperl PDF

    k-adp1

    Abstract: Thermocouple Type B kfd2-ut transformer pt-100 kfd2 signal converter pt100 RS-232PC
    Text: P R O C E S S A U T O M A T I O N Converter KFD2-UT-Ex1 Input EEx ia IIC - Single Channel - Input EEx ia IIC Class I, Div 1, Groups A-G cold junction compensation Typ K-CJC Thermocouple - Output: 4 . 20mA 2- - Optional 1 . 5V Output - Setting options through Serial Interface:


    Original
    Pt100 24VDC 4-20mA k-adp1 Thermocouple Type B kfd2-ut transformer pt-100 kfd2 signal converter pt100 RS-232PC PDF

    IEC 60947-5-6

    Abstract: namur standard LFL-Z231 60947-5-6 LFL-Z131 float switch LIMIT SWITCH namur application 68307 Pepperl Fuchs kfd2 LFL-Z32
    Text: Pepperl+Fuchs offers a wide range of float switches: Application - suitable for use up to Ex-area zone 1 - mercury-free switching element - nominal voltage, 8 V per EN 60947-5-6 NAMUR - connected through a transformer isolated barrier (i.e. KFD2-SR.) - mercury-free switching element


    Original
    PDF

    KFD2-SR2-Ex2.W

    Abstract: IEC 60947-5-6 NE44 kfd2-eb2 60947-5-6 kfd2 atex transformer Pepperl Fuchs kfd2 Ignition Transformer namur standard
    Text: Transformer Isolated Barriers KFD2-SR2-Ex2.W Output: Relay Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ 6- 400 Ω ≤ R ≤ 2 kΩ 10 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I 24 V DC: without SC • • • • 2-channel Control circuit EEx ia IIC


    Original
    PDF

    kfd2-stc4

    Abstract: BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 UPR-03 EN 50014 to 50020
    Text: KFD2-STC4-Ex1 SMART transmitter power supply Connection • 1-channel • Device installation permissible in zone 2 • Input EEx ia IIC; Uo = 25.4 V • Galvanically isolated output • 24 V DC supply voltage • SMART capable up to 7.5 kHz -3 dB • EMC acc. to NAMUR NE 21


    Original
    PR-03 UPR-03 kfd2-stc4 BAS 99 ATEX 7060 kfd2-stc4-ex1 bas99 EN50-020 atex 7060 kfd2-eb2 61508 EN 50014 to 50020 PDF

    BAS 99 ATEX 7060

    Abstract: KFD2-STC4-Ex1 kfd2 stc4 ex1 transmitter 4-20ma Hart "intrinsically safe" kfd2-stc4 atex 7060 kfd2 k-system isolated 4 to 20ma analog transmitter circuit Isolated 4-20ma
    Text: KFD2-STC4-Ex1 Technical Data POWER SUPPLY Power Rail or terminals 14+, 1520-35 VDC Nominal voltage Power consumption 1.9 W INPUT intrinsically safe Terminals 1+, 2-, 3 or 5-, 6+ 0/4-20 mA Input signal Model Number ≥16 V at 20 mA terminals 1+, 3 Available voltage


    Original
    4-20mA BAS 99 ATEX 7060 KFD2-STC4-Ex1 kfd2 stc4 ex1 transmitter 4-20ma Hart "intrinsically safe" kfd2-stc4 atex 7060 kfd2 k-system isolated 4 to 20ma analog transmitter circuit Isolated 4-20ma PDF

    50mA fuse

    Abstract: 4-20ma to 2-10v converter Voltage to Current Converter circuit 4-20mA kfd2-cd-ex1.32 kfd2
    Text: P R O C E S S A U T O M A T I O N - Single Channel Hazardous area TIBs for Current / Voltage KFD2-CD-Ex1.32 Output EEx ia IIC - Output EEx ia IIC Class I, Div 1, Groups A-G ? J - DC 24 V Nominal Power Supply - Voltage / Current or Current / Voltage Conversion


    Original
    0/4-20mA 0/2-10V 50mA fuse 4-20ma to 2-10v converter Voltage to Current Converter circuit 4-20mA kfd2-cd-ex1.32 kfd2 PDF

    4890A

    Abstract: kfd2
    Text: P R O C E S S A U T O M A T I O N KFD2-SD-Ex1.48 KFD2-SD-Ex1.48.90A Output EEx ia IIC - Single Channel - Output EEx ia IIC Class I, Div 1, Groups A-G - DC 24 V Loop Powered 2- 1+ 2- 1+ Hazardous area Solenoid Drivers KFD2-SD-Ex1.48 - Output Current KFD2-SD-Ex1.48:


    Original
    PDF

    IEC 60947-5-6

    Abstract: 60947-5-6 KFD2-SRA-Ex4 NCN3-F24R-N4 NCB2-12GM35-N0 NCB15 U1 NO NCB15 NCN3-F36-N4 namur standard positioner valve positioners
    Text: Transformer Isolated Barriers KFD2-SRA-Ex* Output: Relay Input EEx ia IIC Input II + - Control circuit EEx ia IIC 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring short circuit LK and interruption LB with LED indicator (red flashing), switching output and


    Original
    15-30GKK-N 15-30GM-N 20-40-N 25-50-N NCN15-M1K-N0 NCB15 NCN20 NCN30 NCN40 NCN3-F24L-N4 IEC 60947-5-6 60947-5-6 KFD2-SRA-Ex4 NCN3-F24R-N4 NCB2-12GM35-N0 NCB15 U1 NO NCN3-F36-N4 namur standard positioner valve positioners PDF

    DN200 PN16

    Abstract: MTL787S DN80-100 MTL787 kfd2 24V 4.20MA 1Gr18Ni9Ti DN200 750DC DC24V
    Text: UBUB-C 型液位变送器 一 概述 UB-C 型液位变送器是浮子式本安防爆液位变送器(以下简称变送器),由 DC 24V 供电,二线制,输出 4~20mA DC 标准确性电流信号,可远传给计算机或显示记录仪表,实现液位的自动检测、控制和记录。


    Original
    420mA L04000mm 45g/cm3 750DC B/T82 DN80-100 DN200 1Gr18Ni9Ti, GYB99212) DN200 PN16 MTL787S MTL787 kfd2 24V 4.20MA 1Gr18Ni9Ti DC24V PDF

    MTL*706

    Abstract: MTL706 schematic inductive sensor flow meter schematic inductive magnetic sensor flow meter MTL5042 MTL3046B Reynolds Electronics WE77 FZ100 TP5041
    Text: LZZ Series Intelligent Metal Tube Float Flowrate Transmitter Summary LZZ Series Intelligent Metal Tube Float Flowrate Transmitter can apply to the measurement for small flow rate, low Reynolds number fluid flow with functions of the local indication or signal remote transmission. The remote


    Original
    4-20mA TP5041-Ex, TP5045-Ex MTL*706 MTL706 schematic inductive sensor flow meter schematic inductive magnetic sensor flow meter MTL5042 MTL3046B Reynolds Electronics WE77 FZ100 TP5041 PDF

    powercode

    Abstract: Primarion TEMPERATURE CONTROLLER with pid kfd2 Primarion driver trim pid controller AN1236 ISL6595 VR11 PRIMARION px3
    Text: Digital Multiphase Software User’s Guide Application Note December 13, 2005 AN1236.0 Author: Thomas Victorin Overview The ISL6595 memory space is partitioned into a Non-Volatile Memory NVM space and a register space. Operation of the ISL6595 is controlled by the contents of the registers. The


    Original
    AN1236 ISL6595 powercode Primarion TEMPERATURE CONTROLLER with pid kfd2 Primarion driver trim pid controller VR11 PRIMARION px3 PDF

    KFA6-SR2-Ex2.W

    Abstract: IEC 60947-5-6 KFD2-SR2-Ex2.W KFa5-SR2-Ex2.W kfd2-sr-ex2 atex transformer E 106378 60947-5-6 namur standard kfa5-sr2
    Text: Transformer Isolated Barriers Input I EEx ia IIC Input II EEx ia IIC 1+ 3- 4+ 3- 4+ 3- 4+ 3- 4+ Switch S3 in position I 2-channel Control circuit EEx ia IIC Reversible mode of operation 1 signal output with 1 changeover contact per channel • EMC acc. to NAMUR NE 21


    Original
    PDF

    NMG125

    Abstract: vec121
    Text: Level measurement Level Sensors / Transmitters to measure of liquids media Applications  Chemical, petrochemical, liquid natural gas, off-shore  ship-building, machine-building industry  manufacturing industry, power plants  pharmaceutical industry, beverage- and food industry,


    Original
    TF90R NMG125 vec121 PDF

    53RT2110

    Abstract: ABB variable area flowmeter D10A3220 D10A3225 D163A011U03 10A3225 10A3220 FAM3225 KFa5-SR2-Ex2.W KFA6-SR2-EX2.W
    Text: Data Sheet D184S042U02 • Function – The armored variable area flowmeter offers new possibilities for metering small flowrates of liquids and gases. The instrument is particularly well suited for metering cloudy, opaque or aggressive fluids. ■ Application


    Original
    D184S042U02 10A3220) D184S042U02 53RT2110 ABB variable area flowmeter D10A3220 D10A3225 D163A011U03 10A3225 10A3220 FAM3225 KFa5-SR2-Ex2.W KFA6-SR2-EX2.W PDF