Untitled
Abstract: No abstract text available
Text: Technical data sheet TDS031 NITROUS OXIDE INFRARED SENSOR TEMPERATURE COMPENSATED CERTIFIED VERSION TYPE MSH-N2O/TC PATENT NUMBER: GB 2372099B; US 6,753,967 B2 FEATURES ▪ ▪ ▪ ▪ High sensitivity to nitrous oxide Standard sensor size Fast Response Internal temperature signal
|
Original
|
TDS031
2372099B;
04ATEX1357U,
0053U,
|
PDF
|
helium sensor
Abstract: AWM42150VH nitrogen gas sensor hydrogen and carbon monoxide gas sensor nitric oxide gas sensor gas sensor helium types methane gas sensor gas sensor no2 Transistor A131 helium gas sensor
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors – Note #3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temperature sensing resistor located on either side of the heater. The
|
Original
|
|
PDF
|
hydrogen gas sensor
Abstract: nitric oxide gas sensor GAS SENSOR for oxygen AWM1000 helium sensor AWM40000 AWM42150VH AWM5000 AWM2100VH oxygen gas sensor
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility – Note #4 The microbridge mass airflow sensor incorporates a limited number of wetted materials in the construction of the device. The wetted materials in the sensor are fairly non-reactive and are compatible
|
Original
|
AWM2100VH,
AWM2300VH,
AWM42150VH.
hydrogen gas sensor
nitric oxide gas sensor
GAS SENSOR for oxygen
AWM1000
helium sensor
AWM40000
AWM42150VH
AWM5000
AWM2100VH
oxygen gas sensor
|
PDF
|
MEMS blood pressure sensor
Abstract: MEMS pressure sensor omron pressure sensor A D8M OMRON MEDICAL PRESSURE SENSOR "Air Flow Sensor", medical electronic air pressure sensor blood pressure measurement sensor Pressure Sensor "Blood Pressure Sensor" mems
Text: Omron’s D8M Pressure Sensor Detects Minute Pressure Differential SCHAUMBURG, IL April 25, 2005 —Using MEMS technology, the Omron D8M pressure sensor accurately detects extremely small increments of pressure differential, in the range of hundredths of 1 psi, to measure slight variations in air or gas flow. Five models of the D8M offer
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: GAS CONVERSION FACTORS For FMA-5600, FMA-5700 and FMA-8500 Flow Sensors The FMA-5600, FMA-700/800 , and FMA-8500 Electronic Mass Flowmeters and Controllers are factory calibrated for nitrogen, N2 . However, these units can be used for many gases, with the
|
Original
|
FMA-5600,
FMA-5700
FMA-8500
FMA-700/800
FMA-5600
FMA-8500
C4H10)
FMA-8506
|
PDF
|
medical oxygen Sensor
Abstract: datex ohmeda oxygen Sensor "oxygen sensor" R-23MED PPG SENSOR oxygen sensor circuited oxygen sensor medical sensor oxygen 15201A
Text: TELEDYNE ANALYTICAL INSTRUMENTS The R-23MED Dual Cathode Oxygen Sensor is a recommended replacement for • • • • • • Dragerwerke 68-50645, 68-03290, Hewlett Packard 15201A North American Drager 68-50645 P.P.G. 505055-001 Oxitron 3710 Datex/Ohmeda 6850260, 0237-2034 –700
|
Original
|
R-23MED
5201A
3/00LD
medical oxygen Sensor
datex ohmeda oxygen Sensor
"oxygen sensor"
PPG SENSOR
oxygen sensor
circuited oxygen sensor
medical sensor
oxygen
15201A
|
PDF
|
helium sensor
Abstract: "Flow Sensor" AWM42000 hydrogen gas sensor AWM42150VH nh3 sensor gas sensor helium gas sensor no2 AWM42150VH application nitric oxide sensor
Text: AWM42000 Series Mass flow sensor for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/o-ring sealed SERVICE To be used with dry gases only. The AWM42150VH is a special sensor for
|
Original
|
AWM42000
AWM42150VH
AWM42150VH
AWM42300V
helium sensor
"Flow Sensor"
hydrogen gas sensor
nh3 sensor
gas sensor helium
gas sensor no2
AWM42150VH application
nitric oxide sensor
|
PDF
|
medical oxygen Sensor
Abstract: NOx sensor oxygen sensor R-29MED nitrous oxide sensor MB SERIES
Text: TELEDYNE ANALYTICAL INSTRUMENTS Teledyne’s R-29MED is designed for direct replacement of sensors used in Ceramatec’s MAXO2 series of analyzers. This component offers a cost-effective, replacement sensor solution from the company known for its long tradition of providing stable,
|
Original
|
R-29MED
3/01LD
medical oxygen Sensor
NOx sensor
oxygen sensor
nitrous oxide sensor
MB SERIES
|
PDF
|
AWM5000
Abstract: AWM5104VN medical flow sensor bypass air flow sensor
Text: AWM5104VN Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: 0 SLPM to 20.0 SLPM; Port Style: Threaded, ¼ NPT Actual product appearance may vary. Features Potential Applications Linear voltage output Venturi design ● Remote mounting capability
|
Original
|
AWM5104VN
AWM5000
AWM5104VN
medical flow sensor bypass
air flow sensor
|
PDF
|
AWM5102VN
Abstract: AWM5000 flow orifice "Air Flow Sensor", medical medical oxygen Sensor
Text: AWM5102VN Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: 0 SLPM to 10.0 SLPM; Port Style: Threaded, ¼ NPT Actual product appearance may vary. Features Potential Applications Linear voltage output Venturi design ● Remote mounting capability
|
Original
|
AWM5102VN
AWM5102VN
AWM5000
flow orifice
"Air Flow Sensor", medical
medical oxygen Sensor
|
PDF
|
AWM5101VN
Abstract: AWM5000 flow orifice argon sensor
Text: AWM5101VN Airflow Sensor, Signal Conditioning: Amplified; Flow/Pressure Range: 0 SLPM to 5.0 SLPM; Port Style: Threaded, ¼ NPT Actual product appearance may vary. Features Potential Applications Linear voltage output Venturi design ● Remote mounting capability
|
Original
|
AWM5101VN
AWM5101VN
AWM5000
flow orifice
argon sensor
|
PDF
|
AWM43000
Abstract: hydrogen gas sensor AWM43300V "Flow Sensor" hydrogen sensor helium sensor AWM43600V ch4 sensor methane carbon dioxide sensor nitrogen dioxide sensor
Text: AWM43000 Series Mass flow sensor for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/o-ring sealed SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through
|
Original
|
AWM43000
AWM43300V
AWM43600V
AWM43300VH
hydrogen gas sensor
AWM43300V
"Flow Sensor"
hydrogen sensor
helium sensor
AWM43600V
ch4 sensor
methane carbon dioxide sensor
nitrogen dioxide sensor
|
PDF
|
helium sensor
Abstract: "Flow Sensor" LP GAS PRESSURE DEVICE SENSOR AWM700 medical Flow Sensor "Flow Sensor", medical AWM720P1 gas sensor helium liquid flow sensor Flow sensor
Text: AWM700 Series Mass flow sensor for gases FEATURES • Ranges 0.200 slpm1 · Actual mass flow sensing · 1.5 V output SERVICE To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor
|
Original
|
AWM700
AWM720P1
helium sensor
"Flow Sensor"
LP GAS PRESSURE DEVICE SENSOR
medical Flow Sensor
"Flow Sensor", medical
AWM720P1
gas sensor helium
liquid flow sensor
Flow sensor
|
PDF
|
FDUH002DB
Abstract: Flow Sensors hydrogen gas sensor helium gas sensor "Flow Sensor" FDUM200DB CO2 SENSOR sensortechnics flow sensor
Text: FDU Series Mass flow sensors for gases FEATURES • Ranges 0.±200 sccm1 or 0.±2 "H2O 0.±5 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only
|
Original
|
|
PDF
|
|
"Flow Sensor"
Abstract: helium sensor AWM2100V AWM2200V AWM2000 6 pin gas sensor AWM2150V AWM2300V AWM2300VH AWM2100VH
Text: AWM2000 Series Mass flow sensor for gases FEATURES • Ranges 0.±30 to 0.±1000 sccm1 or 0.±4 "H2O 0.±10 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid
|
Original
|
AWM2000
gas11
AWM2150V
AWM2100V
AWM2100VH
AWM2300V
AWM2300VH
AWM2200V
"Flow Sensor"
helium sensor
AWM2100V
AWM2200V
6 pin gas sensor
AWM2150V
AWM2300V
AWM2300VH
AWM2100VH
|
PDF
|
"Flow Sensor"
Abstract: helium sensor hydrogen gas sensor AWM90000 AWM92100V AWM92200V CO2 SENSOR liquid density sensor nitrous oxide sensor gas sensor CO
Text: AWM90000 Series Mass flow sensor for gases FEATURES • Ranges 0.±200 sccm1 or 0.±2 "H2O 0.±5 mbar · Bidirectional sensing · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only The AWM series is NOT designed for liquid
|
Original
|
AWM90000
AWM92100V
AWM92200V
"Flow Sensor"
helium sensor
hydrogen gas sensor
AWM92100V
AWM92200V
CO2 SENSOR
liquid density sensor
nitrous oxide sensor
gas sensor CO
|
PDF
|
"Flow Sensor"
Abstract: Flow Sensors FMOM025HB NO2 sensor SensorTechnics mass flow
Text: FMO Series Mass flow sensors for gases FEATURES • Ranges 0.±25 and 0.±1000 sccm1 · Bidirectional sensing · Actual mass flow sensing · Ceramic flow tube · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only.
|
Original
|
FMOM025HB
"Flow Sensor"
Flow Sensors
NO2 sensor
SensorTechnics mass flow
|
PDF
|
"Flow Sensor"
Abstract: FMAL001D
Text: FMA Series Mass flow sensors for gases FEATURES • Ranges 0.1000 sccm1 and 0.6 slpm2 · Actual mass flow sensing · 1.5 V output · Manifold mount/O-ring sealed · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FMA series is NOT designed for liquid
|
Original
|
FMAL001DU
FMAL006DU
"Flow Sensor"
FMAL001D
|
PDF
|
AWM3000
Abstract: "Flow Sensor" AWM3303V helium sensor AWM3100V AWM3201CR nitric oxide gas sensor nitric oxide sensor AWM3150V AWM3200CR
Text: AWM3000 Series Mass flow sensor for gases FEATURES • Ranges 0.30 to 0.±1000 sccm1 or 0.0.5 to 0.2 "H2O 0.1.25 to 0.5 mbar · 1.5 V, 1.3.75 V, 4.20 mA output · Actual mass flow sensing · Low differential pressure sensing SERVICE To be used with dry gases only
|
Original
|
AWM3000
AWM3303V
AWM3150V
AWM3100V
AWM3300V
AWM3201CR
AWM3200V
AWM3200CR
"Flow Sensor"
AWM3303V
helium sensor
AWM3100V
AWM3201CR
nitric oxide gas sensor
nitric oxide sensor
AWM3150V
AWM3200CR
|
PDF
|
FBAM200DU
Abstract: Flow Sensors "Flow Sensor" FBAL001 SensorTechnics flow
Text: FBA Series Mass flow sensors for gases FEATURES • Ranges 0.30 to 0.±1000 sccm1 · 1.5 V or 1.3.75 V output · Actual mass flow sensing · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with dry gases only The FBA series is NOT designed for liquid
|
Original
|
FBAL001DB
FBAM200DU
Flow Sensors
"Flow Sensor"
FBAL001
SensorTechnics flow
|
PDF
|
Untitled
Abstract: No abstract text available
Text: thick film printed on alumina Specification Carbon Monoxide See opposite. Methane Feasibility demonstrated at room temperature. gas sensor capability Nitrous Oxide Meggitt Sensors has a major Under initial development phase. development programme for a wide range of gas sensors and
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Correction Factors - Note # 3 Microbridge mass airflow sensors operate by measuring the rate of relative heat transfer from a heater resistor to a temper ature sensing resistor located on either side of the heater. The
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: REFERENCE AND APPLICATION DATA Microbridge Airflow Sensors Gas Media Compatibility - Note # 4 The microbridge mass airflow sensor in corporates a limited number of wetted materials in the construction of the de vice. The wetted materials in the sensor
|
OCR Scan
|
AWM21OOVH,
AWM2300VH,
AWM42150VH.
1-800-737-3360Canada
|
PDF
|
acetone gas sensor
Abstract: freon GAS SENSOR
Text: Umwelteinflüsse Environmental Actions SIEMENS 7 Umwelteinflüsse auf Drucksensoren 7 Tabelle 2 Mechanische Belastungen, max. Grenzdaten Environmental Actions on Pressure Sensors Table 2 Mechanical Load Maximum Ratings Beanspruchung Force Richtung Direction
|
OCR Scan
|
40-Serie
acetone gas sensor
freon GAS SENSOR
|
PDF
|