Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3402.99.0004 Rev.: I Description GDT technology up to 2.5 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOC-0000177092
|
PDF
|
electrostatic precipitator
Abstract: No abstract text available
Text: Y76DSE Reversely Switching Dynistors IP VDRM ITSM 250 KA 1800-2000V 25 KA EM Features: n High power n High reliability n Low priceLong life Typical Applications: n Generator for power exciter laser pumping n Pulse energization of electrostatic precipitator
|
Original
|
Y76DSE
800-2000V
ZT73cT
250KA
electrostatic precipitator
|
PDF
|
electrostatic precipitator
Abstract: No abstract text available
Text: Y76DSH Reversely Switching Dynistors IP VDRM ITSM 250 KA 2500-3000V 25 KA EM Features: n High power n High reliability n Low priceLong life Typical Applications: n Generator for power exciter laser pumping n Pulse energization of electrostatic precipitator
|
Original
|
Y76DSH
500-3000V
ZT73cT
250KA
electrostatic precipitator
|
PDF
|
electrostatic precipitator
Abstract: No abstract text available
Text: Y38DSC Reversely Switching Dynistors IP VDRM ITSM 50 KA 1000-1200V 5 KA EM Features: n High power n High reliability n Low priceLong life Typical Applications: n Generator for power exciter laser pumping n Pulse energization of electrostatic precipitator
|
Original
|
Y38DSC
000-1200V
ZT33aT
electrostatic precipitator
|
PDF
|
electrostatic precipitator
Abstract: exciter generator circuit TP50S 180kA ZT60CT65
Text: Y65DSE Reversely Switching Dynistors IP 180 KA VDRM 1800-2000 V ITSM 18 KA EM Features: n High power n High reliability n Low priceLong life Typical Applications: n Generator for power exciter laser pumping n Pulse energization of electrostatic precipitator
|
Original
|
Y65DSE
180KA
ZT60CT65
electrostatic precipitator
exciter generator circuit
TP50S
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3409.17.0037-EX Rev.: E Description High-power/low-IM GDT hybrid technology Benefits Self-extinguishing SEMPER TM functionality Multi-band operation DC continuity for outdoor powering The protector can also be installed reversely
|
Original
|
0037-EX
MH74/M8/brk
DOU-00071006
DOC-0000176104
DOC-0000241141
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.17.L Rev.: F Description GDT technology up to 1.0 GHz Benefits DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOC-0000176946
|
PDF
|
3401.17.C
Abstract: 90719-905 MH12 DOC-0000176104
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.17.C Rev.: K Description GDT technology up to 1.0 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas capsule Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOU-00057092
DOC-0000176104
DOC-0000176943
3401.17.C
90719-905
MH12
DOC-0000176104
|
PDF
|
MH69
Abstract: DOC-0000176104
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3400.17.0380 Rev.: G Description Quarter-wave stub technology Benefits Broad-band operation The protector can also be installed reversely Compliant to IEC 61643-21 Product Configuration Main path connectors Mounting and grounding
|
Original
|
DOC-0000176665
MH69
DOC-0000176104
|
PDF
|
reversely
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3406.17.0012 Rev.: N Description Slim Line GDT technology Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Permanently installed gas discharge tube Compliant to IEC 61643-21
|
Original
|
15ver
DOC-0000177181
reversely
|
PDF
|
DOU-00057120
Abstract: MH12 GDT 230
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.01.A Rev.: G Description GDT technology up to 1.0 GHz Benefits DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
W920-12-325-4220,
DOC-0000176907
DOU-00057120
MH12
GDT 230
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3404.00.0006 Rev.: F.00 Description Miniature GDT technology Benefits DC continuity for outdoor powering The protector can also be installed reversely Permanently installed gas discharge tube Static sparkover voltage typ. 230 V
|
Original
|
DOC-0000177153
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3406.17.0009 Rev.: L Description Slim Line GDT technology Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Permanently installed gas discharge tube Compliant to IEC 61643-21
|
Original
|
DOC-0000177177
|
PDF
|
DOC-0000176104
Abstract: DOU-00019177 3402.17A 3402.17.A DOC-0000176104 H 3402.17 MH25
Text: HUBER+SUHNER DATA SHEET Lightning Protector: 3402.17.A Rev.: H Description Gas Capsule Lightning Protector up to 2.5 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas capsule
|
Original
|
DOU-00019177
DOC-0000176104
DOC-0000177037
DOC-0000176104
3402.17A
3402.17.A
DOC-0000176104 H
3402.17
MH25
|
PDF
|
|
GDT 230
Abstract: MH12 90719-905
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.00.0022 Rev.: F Description GDT technology up to 1.0 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas capsule Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOU-00057123
DOC-0000176104
DOC-0000176883
GDT 230
MH12
90719-905
|
PDF
|
3401.17.0033
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.17.0033 Rev.: F Description GDT technology up to 1.0 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
MH12/M8
DOU-00068967
DOC-0000176104
DOC-0000176930
3401.17.0033
|
PDF
|
DOU-00003897
Abstract: 7610 MH12
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.02.A Rev.: G Description GDT technology up to 1.0 GHz Benefits DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOC-0000176913
DOU-00003897
7610
MH12
|
PDF
|
MH12
Abstract: US2KA
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.17.C Rev.: K Description GDT technology up to 1.0 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOU-00057092
DOC-0000176104
DOC-0000176943
MH12
US2KA
|
PDF
|
GDT 230
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3402.17.0043 Rev.: G Description GDT technology up to 2.5 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
MH12/M8
DOU-00068855
DOC-0000176104
DOC-0000177015
GDT 230
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3402.41.A Rev.: J Description GDT technology up to 2.5 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOU-00004154
DOC-0000176104
DOC-0000177089
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Y38DSF Reversely Switching Dynistors IP VDRM ITSM 50 KA 2000-2500V 5 KA EM Features: n High power n High reliability n Low priceLong life Typical Applications: n Generator for power exciter laser pumping n Pulse energization of electrostatic precipitator
|
Original
|
Y38DSF
000-2500V
ZT33aT
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.01.C Rev.: F Description GDT technology up to 1.0 GHz Benefits DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
DOU-00003898
DOC-0000176104
DOC-0000176908
|
PDF
|
GDT 230
Abstract: DOC-0000176104 3402.17
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3402.17.0044 Rev.: G Description GDT technology up to 2.5 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas capsule Data refer to GDT 9071.99.0547, 230 V
|
Original
|
MH12/M8
DOU-00003926
DOC-0000176104
DOC-0000177017
GDT 230
DOC-0000176104
3402.17
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HUBER+SUHNER DATA SHEET EMP Protector: 3401.00.0022 Rev.: G Description GDT technology up to 1.0 GHz Benefits Broad-band operation DC continuity for outdoor powering The protector can also be installed reversely Delivered without gas discharge tube Data refer to GDT 9071.99.0547, 230 V
|
Original
|
100rawing
DOC-0000176883
|
PDF
|