Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TM405 Search Results

    SF Impression Pixel

    TM405 Price and Stock

    SMC Corporation of America CXTM40-50

    CYLINDER, PLATFORM, GUIDE ROD, 40MM BORE, CXTM SERIES | SMC Corporation CXTM40-50
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS CXTM40-50 Bulk 5 Weeks 1
    • 1 $570.69
    • 10 $570.69
    • 100 $570.69
    • 1000 $570.69
    • 10000 $570.69
    Get Quote

    SMC Corporation of America CXTM40-50B

    CYLINDER, PLATFORM, GUIDE ROD, 40MM BORE, CXTM SERIES | SMC Corporation CXTM40-50B
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS CXTM40-50B Bulk 5 Weeks 1
    • 1 $672.06
    • 10 $672.06
    • 100 $672.06
    • 1000 $672.06
    • 10000 $672.06
    Get Quote

    SMC Corporation of America CXTM40-50BS

    PLATFORM CYLINDER, CXT SERIES | SMC Corporation CXTM40-50BS
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS CXTM40-50BS Bulk 5 Weeks 1
    • 1 $621.37
    • 10 $621.37
    • 100 $621.37
    • 1000 $621.37
    • 10000 $621.37
    Get Quote

    SMC Corporation of America CXTM40-50-X138

    GUIDED CYLINDER, PLATFORM, SLIDE BEARING, CXT SERIES | SMC Corporation CXTM40-50-X138
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS CXTM40-50-X138 Bulk 5 Weeks 1
    • 1 $571.43
    • 10 $571.43
    • 100 $571.43
    • 1000 $571.43
    • 10000 $571.43
    Get Quote

    SMC Corporation of America CXTM40-50B-X138

    GUIDED CYLINDER, PLATFORM, SLIDE BEARING, CXT SERIES | SMC Corporation CXTM40-50B-X138
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    RS CXTM40-50B-X138 Bulk 5 Weeks 1
    • 1 $672.06
    • 10 $672.06
    • 100 $672.06
    • 1000 $672.06
    • 10000 $672.06
    Get Quote

    TM405 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    sensotec lvdt

    Abstract: AY321 Sensotec* SC1000
    Text: Model JEC DC-DC Long Stroke LVDT Order Code AY321 n n n Stainless Steel Voltage Regulation Reverse Polarity Protected Dimensions Wiring Code Dual Supply M5 x .08 ø 0.81 in. 0.35 in. Range Codes Available Stroke Ranges L in. Red Blue X (in.) Approx. Body


    Original
    AY321 sensotec lvdt AY321 Sensotec* SC1000 PDF

    threads

    Abstract: TM49 TM511 TM405 BENDIX
    Text: Model JEC DC-DC Long Stroke Displacement Transducer DESCRIPTION Models JEC free unguided armature dc-dc long stroke that sensitivity will remain constant over large variations in sup- displacement transducers utilize an improved internal circuit ply voltage. These models require no further conditioning, thus


    Original
    008763-1-EN threads TM49 TM511 TM405 BENDIX PDF

    TM49

    Abstract: No abstract text available
    Text: Model JEC-C DC-DC Long Stroke Displacement Transducer DESCRIPTION Model JEC-C captive guided armature dc-dc long stroke dis- if supply voltage is accidentally reversed and ensure that sensi- placement transducer utilizes an improved internal circuit which


    Original
    008764-1-EN TM49 PDF

    PM55L-048

    Abstract: LW - 6052 Clock Display LED PM35L-048 PM35S-048 5 pin relay 12vdc 4088 UP 5035 LCD METER diagram wiring mitsubishi elevator digital dC Ammeter stu 4465 OMRON plc programming manual ZEN-10C1DR-D-V2
    Text: ND3% BASE1 XXXX7196-1888-1-P 1888 TSQ: 3001 CMS: CMS-USM TS host OP: NN COMP: 19-07-11 Hour: 11:01 TS:TS date TS time PANEL INSTRUMENTATION Find Datasheets Online ANALOG 2% CENTURY PANEL METERS ROUND AND RECTANGULAR PANEL METERS Attractive, easy-to-read meters in black


    Original
    55F5412 55F5413 55F5252 55F5253 55F5254 55F5255 55F5256 55F5257 SCE016XD3SU2B SCE028LD3DP2B PM55L-048 LW - 6052 Clock Display LED PM35L-048 PM35S-048 5 pin relay 12vdc 4088 UP 5035 LCD METER diagram wiring mitsubishi elevator digital dC Ammeter stu 4465 OMRON plc programming manual ZEN-10C1DR-D-V2 PDF

    BY125

    Abstract: AA937 IEEE 1451.4 Sensotec wiring diagram Sensotec* SC1000 IEEE 1451.4 temperature Sensotec 42 Sensotec model dm
    Text: Model MVL7 AC-AC Long Stroke LVDT Order Code BY125 n n n 0.25% Non-Linearity Stainless Steel 0.5 to 8.0 in. Ranges Dimensions Wiring Codes M5 x .08 ø 0.81 in. Range Codes HP HQ HR HS HT HU HV 0.35 in. Available Stroke Ranges L in. X (in.) +/+/+/+/+/+/+/-


    Original
    BY125 BY125 AA937 IEEE 1451.4 Sensotec wiring diagram Sensotec* SC1000 IEEE 1451.4 temperature Sensotec 42 Sensotec model dm PDF

    Sensotec wiring diagram

    Abstract: AY323
    Text: Model JEC-C DC-DC Long Stroke LVDT Order Code AY323 n n n Voltage Regulation Easy to Operate Reverse Polarity Protection Dimensions Wiring Code Dual Supply M5 x 0.8 ø 0.82 in. X Nominal Electric Zero Point 0.91 in. L ø 0.19 in. Range Codes Available Stroke Ranges


    Original
    AY323 Sensotec wiring diagram AY323 PDF

    TM49

    Abstract: No abstract text available
    Text: Model DLB DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLB free unguided displacement transducer operates digital panel meters to from a complete readout system. The from either 5 Vdc regulated or 6 Vdc to 18 Vdc unregulated DLB, free unguided is available with stroke ranges of ±0.5 in to


    Original
    008760-1-EN TM49 PDF

    TM49

    Abstract: model JEC-AG IN209
    Text: Model JEC-AG DC-DC Long Stroke Displacement Transducer DESCRIPTION Models JEC-AG captive guided spring return dc-dc long stroke damage if supply voltage is accidentally reversed, and ensure displacement transducer utilizes an improved internal circuit that sensitivity will remain constant over large variations in sup-


    Original
    008762-1-EN TM49 model JEC-AG IN209 PDF

    TM49

    Abstract: No abstract text available
    Text: Model DLF DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLF captive guided spring return operates from either 5 from the input voltage and can be used with digital panel meters Vdc regulated or 6 Vdc to 18 Vdc unregulated and generate an to from a complete readout system. The DLF, captive guided


    Original
    008759-1-EN TM49 PDF

    TM315

    Abstract: TM49 VL7A
    Text: Model VL7A AC-AC Long Stroke Displacement Transducer DESCRIPTION Model VL7A spring return armature ac-ac long stroke displace- impressive 0.25 % full scale non-linearities. Displacement trans- ment transducer is designed for measuring static and dynamic


    Original
    008751-1-EN TM315 TM49 VL7A PDF

    TM315

    Abstract: TM49 MVL7
    Text: Model MVL7 AC-AC Long Stroke Displacement Transducer DESCRIPTION Model MVL7 free unguided armature ac-ac long stroke achieves an impressive 0.25 % full scale non-linearities. Dis- displacement transducer is designed for measuring static and placement transducer bodies and probes are constructed of


    Original
    008752-1-EN TM315 TM49 MVL7 PDF

    by129

    Abstract: sensotec lvdt Sensotec bendix
    Text: Model DLF DC-DC Long Stroke LVDT Order Code BY129 n n n n Low Voltage Requirements Easy to Operate Stainless Steel Reverse Polarity Protected Wiring Codes Dimensions ø 0.19 in. 0.35 in. ø 0.81 in. X Nominal Electric Zero Point L Range Codes Available Stroke


    Original
    BY129 6-18VDC TM405. TM406. TM511. by129 sensotec lvdt Sensotec bendix PDF

    TM49

    Abstract: displacement transducer in4445
    Text: Model DLE DC-DC Long Stroke Displacement Transducer DESCRIPTION Model DLE captive guided armature operates from either 5 from the input voltage and can be used with digital panel meters Vdc regulated or 6 Vdc to 18 Vdc unregulated and generate an to from a complete readout system. The DLE, captive guided


    Original
    008761-1-EN TM49 displacement transducer in4445 PDF

    hy 1417

    Abstract: TM315 TM49 MVL7C
    Text: Model MVL7C AC-AC Long Stroke Displacement Transducer DESCRIPTION Model MVL7C captive guided armature ac-ac long stroke achieves an impressive 0.25 % full scale non-linearity. Displace- displacement transducer is designed for measuring static and ment transducer bodies and probes are constructed of stainless


    Original
    008753-1-EN hy 1417 TM315 TM49 MVL7C PDF