Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    VS1201 Search Results

    SF Impression Pixel

    VS1201 Price and Stock

    ELKO VS120-10UL-230V-AC

    DIN Contactor 1X20A NO 230V AC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com VS120-10UL-230V-AC
    • 1 $24.02
    • 10 $24.02
    • 100 $24.02
    • 1000 $24.02
    • 10000 $24.02
    Buy Now

    ELKO VS120-10UL-120V-AC

    DIN Contactor 1X20A NO 120V AC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com VS120-10UL-120V-AC
    • 1 $24.64
    • 10 $24.64
    • 100 $24.64
    • 1000 $24.64
    • 10000 $24.64
    Buy Now

    ELKO VS120-10UL-230V-AC/DC

    DIN Contactor 1X20A NO 230V AC/DC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com VS120-10UL-230V-AC/DC
    • 1 $26.1
    • 10 $26.1
    • 100 $26.1
    • 1000 $26.1
    • 10000 $26.1
    Buy Now

    ELKO VS120-10UL-120V-AC/DC

    DIN Contactor 1X20A NO 120V AC/DC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com VS120-10UL-120V-AC/DC
    • 1 $26.8
    • 10 $26.8
    • 100 $26.8
    • 1000 $26.8
    • 10000 $26.8
    Buy Now

    ELKO VS120-10UL-24V-AC

    DIN Contactor 1X20A NO 24V AC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Onlinecomponents.com VS120-10UL-24V-AC
    • 1 $24.02
    • 10 $24.02
    • 100 $24.02
    • 1000 $24.02
    • 10000 $24.02
    Buy Now

    VS1201 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8986, S10128 Front-illuminated FFT-CCDs for X-ray imaging S8986 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8986 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. S8986 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode.


    Original
    PDF S8986, S10128 S8986 S10128 S10127

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S10814 S10811 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S10814 S10811 S10811 S10814, SE-171 KMPD1124E01

    x-ray

    Abstract: VS1202 vs1200 dental sensor S1700 S1701 S1702 S1703 P2HNC
    Text: CCD area image sensors S10814 S10811 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S10814 S10811 S10814 S10811 S10814, SE-171 KMPD1124E02 x-ray VS1202 vs1200 dental sensor S1700 S1701 S1702 S1703 P2HNC

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8986 Front-illuminated FFT-CCD for X-ray imaging S8986 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8986 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. S8986 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode. Moreover, use of the low-noiseamplifier achieves a wide dynamic range.


    Original
    PDF S8986 S8986 SE-171 KMPD1086E01

    S8985-02C

    Abstract: MDR 26 pin 3M
    Text: CCD area image sensor S10811 Front-illuminated FFT-CCD for X-ray imaging The S10811 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10811 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S10811 S10811 S8985-02C S10810 SE-171 KMPD1110E01 MDR 26 pin 3M

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8986, S10128 Front-illuminated FFT-CCDs for X-ray imaging S8986 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8986 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. S8986 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode.


    Original
    PDF S8986, S10128 S8986 S10128 S10127

    pin out mdr 50 pin CONNECTOR

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171 pin out mdr 50 pin CONNECTOR

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02C Front-illuminated FFT-CCDs for X-ray imaging The S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8984, S8985-02C S8984 S8985-02C SE-171 KMPD1085E05

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02C Front-illuminated FFT-CCDs for X-ray imaging The S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8984, S8985-02C S8984 S8985-02C SE-171 KMPD1085E04

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S10814 S10811-11 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as


    Original
    PDF S10814 S10811-11 S10814 S10811-11 S10814, KMPD1124E05

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S10814 S10811 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S10814 S10811 S10811 S10814, SE-171 KMPD1124E03

    S10811-11

    Abstract: S10811
    Text: CCD area image sensors S10814 S10811-11 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as


    Original
    PDF S10814 S10811-11 S10811-11 S10814, SE-171 KMPD1124E04 S10811

    dental image sensor x-ray

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171 dental image sensor x-ray

    VS1202

    Abstract: dental sensor image sensor x-ray S1702 S1700 S1701 S1703 S8984 S8985-02 scintillator amplifier
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02C Front-illuminated FFT-CCDs for X-ray imaging The S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. The S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation,


    Original
    PDF S8984, S8985-02C S8984 S8985-02C SE-171 KMPD1085E03 VS1202 dental sensor image sensor x-ray S1702 S1700 S1701 S1703 S8985-02 scintillator amplifier

    S8985-02

    Abstract: S1700 S1701 S1702 S8981-02 S8984 S8985 vs1200
    Text: IMAGE SENSOR CCD area image sensor S8984, S8985-02 Front-illuminated FFT-CCDs for X-ray imaging S8984 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8984 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. The fiber optic plate (FOP) used as an input window is as thin as 1.5 mm but highly resistant to X-ray irradiation, making


    Original
    PDF S8984, S8985-02 S8984 S8985-02 S898502 S8981-02 SE-171 S1700 S1701 S1702 S8981-02 S8985 vs1200

    dental sensor

    Abstract: x-ray S10127 S10128 S1700 S1701 S1702 S1703 S8985-02 S8986
    Text: IMAGE SENSOR CCD area image sensor S8986, S10128 Front-illuminated FFT-CCDs for X-ray imaging S8986 is an FFT-CCD image sensor ideal for intra-oral X-ray imaging in dental diagnosis. S8986 has about 2 mega 1700 x 1200 pixels each of which is 20 × 20 µm. S8986 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode.


    Original
    PDF S8986, S10128 S8986 S10128 S10127 dental sensor x-ray S10127 S1700 S1701 S1702 S1703 S8985-02

    Untitled

    Abstract: No abstract text available
    Text: CCD area image sensors S10814 S10811 Front-illuminated FFT-CCD for X-ray imaging The S10814 is an FFT-CCD image sensor suitable for intra-oral X-ray imaging in dental diagnosis. The S10814 has about 2 mega 1700 x 1200 pixels, each of which is 20 × 20 m in size. The FOP (fiber optic plate) used as an input window is as thin as 1.5


    Original
    PDF S10814 S10811 S10811 S10814, SE-171 KMPD1124E02

    A41S

    Abstract: AAS-100
    Text: r= 7 S G S -TH O M S O N AVS12 KSID g @lllLll iIIMDD©i AUTOMATIC VOLTAGE SWITCH (SMPS < 500W CONTROLLER • 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION


    OCR Scan
    PDF AVS12 50/60HZ AVS12CB AVS12 110/220V T0220 A41S AAS-100

    TRIAC FT 12

    Abstract: triac 1205 110V Automatic Voltage Regulator avs1ac TRIAC FT 01 VS1201
    Text: Æ T S C S -T H O M S O N AVS12 [* ^ 5 & [i(g ïjW Î* S AUTOMATIC VOLTAGE SWITCH (SMPS < 500W CONTROLLER • 50/60HZ FULL COMPATIBILITY ■ INTEGRATED VOLTAGE REGULATOR ■ TRIGGERING PULSE TRAIN OF THE TRIAC ■ PARASITIC FILTER ■ LOW POWER CONSUMPTION


    OCR Scan
    PDF AVS12 50/60HZ AVS12CB AVS12 110/220V T0220 TRIAC FT 12 triac 1205 110V Automatic Voltage Regulator avs1ac TRIAC FT 01 VS1201